Foamit FG-10N-3 User manual

USER
MANUAL
MODEL NUMBER:
FG-10N-3
FG-10NK-3
FG-10NV-3
AND RELATED UNITS
10 Gallon Air Operated Portable Fog
Equipment
English (Original Instrucons)

Page 2 of 7 | 20221202
User Manual: Portable Fog Units | English
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Model Number: FG-10N-3, FG-10NK-3, FG-10NV-3
WARNING
PROTECT THE ENVIRONMENT
Please dispose of packaging materials, old machine
components, and hazardous uids in an environmentally safe
way according to local waste disposal regulaons.
Always remember to recycle.
Specicaons and parts are subject to change without noce.
Read this manual completely and understand the
machine before operang or servicing it.
• Read all instrucons before installing or operang unit.
• Always wear appropriate personal protecve equipment
(PPE) when operang or servicing unit.
• Always follow all chemical safety precauons and
handling instrucons provided by the chemical
manufacturer and Safety Data Sheet (SDS).
• If this unit is modied or serviced with parts not listed in
this manual, the unit may not operate correctly.
• Always depessurize unit aer use (as described in the
Aer Use Instrucons).
• Do not exceed an incoming air pressure of 100 psi (7
bar).
• Do not exceed a uid temperature of 100˚F (37˚C).
• Always ush the unit with fresh water for 5 minutes
when switching from an alkaline to an acid or an acid to
an alkaline.
• Never use unit with hydrocarbons or ammable
products.
• Only use clean and dry air. Air must be ltered and free
of moisture or pump life will be diminished. If needed,
install an air dryer before unit.
• Do not use an air lubricator before the unit.
• Never use unit if it is damaged or leaking.

Page 3 of 7 | 20221202
User Manual: Portable Fog Units | English
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Model Number: FG-10N-3, FG-10NK-3, FG-10NV-3
OPTIONS
Pump Seal Material
-3
FG-10N
Santoprene (standard)
Viton (V)
Kalrez (K)
Add bold opon codes to item number as shown. For standard opons, no opon code is needed.
Examples:
• FG-10N-3 (standard unit with Santoprene pump seals)
• FG-10NV-3 (unit with Viton pump seals)
REQUIREMENTS
Compressed air requirements 50 psi (3.4 bar) with 9 cfm (254.9 l/min)
Liquid temperature range 40-100˚F (4.4-37˚C)
Chemical compability Chemical products used with this equipment must be formulated for this type of applicaon
and compable with unit materials and pump seals. For more informaon on chemical
compability, consult the manufacturer or SDS for your product or contact our customer
service department.
SPECIFICATIONS
Power type Compressed air
Chemical pickup type Draws from pre-mixed soluon
Number of products unit can
draw from
One product
Sucon line length/diameter 3/8 in. (9.5 mm) inside diameter
Capacity 12.5 gallons (47.32 liters)
Flow rate* 3.7 gal/hour at each nozzle
Pump seals Santoprene, Viton, or Kalrez
Droplet size 15 microns at 50 psi
Coverage area** 1 liter of soluon will cover approximately 1000 cubic feet (up to system max of 47,320 cubic
feet).
Run me from full tank** Approx. 1 hour
Number of nozzles 3 nozzles
Fog mast height range 3.5-8.5 . (1.1-2.6 m)
Wheel type Two 10 inch non-marking wheels
*Diluon rates and ow rates given are based on chemical with viscosity of water and factory air pressure sengs.
**Area covered and run me may vary based on humidity, air ow, and product used.

Page 4 of 7 | 20221202
User Manual: Portable Fog Units | English
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Model Number: FG-10N-3, FG-10NK-3, FG-10NV-3
Assembly Instrucons
1. Remove all components from packaging.
2. Aach the fog nozzle assembly to the top of the fog mast
using the screw provided in the parts package. The fog
nozzles (PFN-N130) should point upwards.
3. Push one end of the red tube into the ng labeled “RED”
on the unit’s back plate.
4. Push one end of the blue tube into the ng labeled
“BLUE” on the unit’s back plate.
5. Connect the other ends of the red and blue tubes to
the fog nozzle assembly. Locate the two tee ngs
(QFT38) with an open port and connect the soluon line
(red) to the liquid tee and the air line (blue) to the air
tee. To determine which tee is air and which is liquid,
trace the clear tubing from the tee to one of the fog
nozzles (PFN-130) – on the body of the nozzle, the air
line is labeled “AIR” and the liquid line is labeled “LIQ.”
Note: Make sure to insert the tubing all the way into the
ngs to ensure proper connecon.
Operaon Instrucons
Always follow all chemical safety precauons and handling
instrucons provided by the chemical manufacturer and Safety
Data Sheet (SDS).
1. Follow all instrucons from chemical manufacturer. Fill the
tank with water and the advised percentage of chemical
concentrate.
2. Place the unit in the area to be fogged.
3. Adjust the fog mast to the desired height. To
change the height, loosen the collar screws,
move the mast up or down as needed, then
r e g h t e n t h e c o l l a r s c r e w s t o s e c u r e t h e m a s t .
Cauon: To prevent injury from collapsing mast, always
support the mast when adjusng height. Always make
sure the collar screws are ght and secure before leng
go of the mast.
4. Ensure the air supply valve (BVB14) is in the closed
posion, and connect a compressed air line to the air inlet
ng (AP25).
5. Open the air supply valve (BVB14) to acvate the unit.
6. Evacuate the area.
7. Aer the unit has stopped fogging, observe all appropriate
safety precauons before reentering area. Close the air
supply valve (BVB14) and disconnect the compressed air
line from the unit.
8. Before moving the unit, always lower the fog mast
completely and secure it in the lowest posion.
Aer Use Instrucons:
1. Flush the unit with fresh water for 5 minutes.
2. Disconnect the air line from the air ng (AP25).
Maintenance Instrucons:
To keep your portable unit operang properly, periodically
perform the following maintenance procedures:
• Check the air pump (P56/P56K/P56V) for wear and leaks.
• Inspect hoses for leaks or excessive wear. Make sure all
hose clamps are in good condion and properly secured.
• Check the sucon tube and screen for debris and clean as
needed.
• Drain compressor tank on a regular basis to ensure proper
operaon of pump.
Troubleshoong Instrucons:
• If air passes through the pump (P56/P56K/P56V) without
cycling, the pump needs to be replaced.
• Check the chemical sucon line and strainer for debris or
damage. Clean or replace as needed. To prevent damage
to the unit, the strainer (STR38-IL) must always be used.
• Check for proper air pressure on air gauge (AG100). Air
regulator (R14) is factory set at 50 psi (3.4 bar).
• If the unit foams at a reduced pressure:
o Check the air compressor supplying the unit. If the
pressure is less than 40 psi, turn the foam unit o
unl the compressor can catch up.
o If the air supply is 50 psi (3.4 bar) or above, check the
AG100, which should read near 50 psi (3.4 bar). If
the AG100 is more or less than 50 psi (3.4 bar), adjust
the pressure by turning the knob on the top of the air
regulator (R14).

Page 5 of 7 | 20221202
User Manual: Portable Fog Units | English
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Model Number: FG-10N-3, FG-10NK-3, FG-10NV-3
SSP12
SSAXLE14
AS1-VS
W15
FWAX15
PVCV34FM
COT
TANK-10N
DFP7
DP-A
Tank Assembly
AIR HOSE ASSEMBLY
ITEM NUMBER: AH30
WATER SEPARATOR
ITEM NUMBER: WS-20CFM
OPTIONAL COMPONENTS
(see parts list for
color opons)

Page 6 of 7 | 20221202
User Manual: Portable Fog Units | English
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Model Number: FG-10N-3, FG-10NK-3, FG-10NV-3
Plate - Inside View
Plate - Back View
SSA14
AP25
BVB14
QFBH38
SEL14M
CT38-15
QFT38
S5161812
EL14M14F
PFN-N130
HBSSEL1438
PVCV34FM
HHPB3414
P56, P56K or P56V
R14
HBSSEL1414
QFEL1438
AG100
STR38-IL
QFSEL38
QFBH38
H38B-F
H14B-F
R25DT (Available per .)
(Available per .)
(Available per .)
H38CP (Available per .)
QFBH38
QFSEL38
H38CP
QFBH38
FG-MAST-10N
QFT38
QF1438
CT38-15
(Available per .)
Fog Mast Assembly
ITEM NUMBER: 3NA-N130-MAST
Fog Mast - Top View
ITEM NUMBER: 3NA-N130

Page 7 of 7 | 20221202
User Manual: Portable Fog Units | English
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Model Number: FG-10N-3, FG-10NK-3, FG-10NV-3
ITEM NUMBER DESCRIPTION
3NA-N130 FG-10N-3 TOP BRACKET ASSEMBLY WITH 3 PFN-N130
NOZZLES
3NA-N130-MAST FG-10N-3 COMPLETE MAST ASSEMBLY
AG100 1.5 INCH DRY MODEL 20 DUAL SCALE GAUGE
AH30 30 FT. AIR HOSE WITH QUICK CONNECT FITTINGS
AP25 AIR FITTING 1/4 MPT X PLUG-NICKEL-PLATED BRASS
AS1-VS 1/4-20 X 1/2 PHIL TRUSS MACH SCREW 19-8 W/516
ORANGE VIBRASEAL PATCH
B103234 10-32 X 3/4 PHIL TRUSS MACH SCR 18-8
B8X58 8-15 X 5/8 inch PHIL FLAT TY-A 316 S.S.
BPS-58SO Back Panel Screw - 5/8 inch with Stand O
BPS-SSR 1/4 INCH PUSHNUT BOLT RETAINER STAINLESS STEEL
BVB14 AIR INLET VALVE - VA BRS 025-4F4F-BT, NICKEL
COT 1/8 X 1 COTTER PIN 18-8 S/S
CT38-15 3/8 INCH X 15 FT COILED BLACK AND CLEAR TUBING-
POLY URETHANE
DFP7 7 INCH HINGED CAP ASSEMBLY - INCLUDES BLACK
CAP, LID FLANGE AND HINGE PIN
DFP7-C 7 INCH FILL CAP POLYPRO BLACK
DFP7-F 7 INCH TANK LID FLANGE POLYPRO
DFP7-PIN HINGE PIN FOR DFP7-C & DFP7-C
DFP7-C-BL 7 INCH FILL CAP POLYPRO BLUE PANTONE
DFP7-C-GN 7 INCH FILL CAP POLYPRO GREEN PANTONE
DFP7-C-RD 7 INCH FILL CAP POLYPRO RED PANTONE
DFP7-C-YL 7 INCH FILL CAP POLYPRO YELLOW PANTONE
DP-A DRAIN PLUG ASSEMBLY FOR TANK-10N TANK-20N
DP FRONT DRAIN PLUG FOR PORTABLE UNIT POLYPRO
DP-G FKM SQUARE CUT DRAIN PLUG GASKET
EC14-2 OETIKER CLAMP 13.8
EL14M14F 1/4 FEM PIPE X 1/4 M PIPE ELBOW
FG-MAST-10N FOG MAST FOR TANK-10N-IN
FWAX15 FLAT AXLE WASHER
FWLG14 .569 ID X 1.28 OD X .08 THICK FLAT WASHER SS 18-8
H14B-F 1/4 INCH BLUE HOSE-HYBRID TPE-Available per .
H38B-F 3/8 INCH BLUE HOSE-HYBRID TPE-Available per .
H38CP 3/8IN OD POLYETHYLENE TUBING - NATURAL
HBSSEL1414 STAINLESS HOSE BARB 1/4 MPT X 1/4 BARB ELBOW
HBSSEL1438 STAINLESS HOSE BARB ELBOW 1/4 INCH NPT X 3/8
HOSE BARB
HHSB1418 HEX HEAD STAINLESS BUSHING 1/4 MPT X 1/8 FPT
HHPB3414 HEX HEAD POLY REDUCER BUSHING 3/4 X 1/4
P56 5700 PUMP WITH SANTOPRENE SEALS - INCLUDES
HOSE BARBS, AIR FITTING, AND AIR PORT
P56K 5700 PUMP WITH KALREZ SEALS - INCLUDES HOSE
BARBS, AIR FITTING, AND AIR PORT
P56V 5700 PUMP WITH VITON SEALS - INCLUDES HOSE
BARBS, AIR FITTING, AND AIR PORT
20756103B Polypro G57 Air Port x HB Straight, w/ Viton o-ring
HB14P 1/4in BRASS HB AIR FITTING /G57/P56
HB5638 HOSE BARB FOR P56 PUMP
HB5638K HOSE BARB FOR P56K PUMP
HB5638V HOSE BARB FOR P56V PUMP
QF5638 3/8in QF PUMP FITTING / G57
PFN-N130 PNEUMATIC FOG NOZZLE - POLYPROPYLENE AND
KYNAR TIP - 3.7 GAL/HR PER NOZZLE
PLPF PORTABLE FOAMER BACK PLATE W/ HOLES-HINGE
SOLD SEPARATELY
PLPF-PIN 302 STAINLESS PORTABLE PLATE HINGE PIN
PVCV34FM PVC VALVE 3/4in FPT X 3/4in MPT
QF1438 MALE CON. 3/8in TUBE X 1/4in MPT -
POLYPROPYLENE
QF5638 3/8in QF PUMP FITTING / G57
QFBH38 BULKHEAD 3/8in TUBE POLYPROPYLENE
QFEL1438 FIXED ELBOW 3/8in TUBE X 1/4in MPT -
POLYPROPYLENE
QFSEL38 PLUG-IN ELBOW 3/8in TUBE X 3/8in POLYPROPYLENE
QFT38 UNION TEE 3/8in TUBE POLYPROPYLENE
R14 1/4 NPTF REGULATOR W/ FILTER-NO GAUGE
R25DT 3/16 X 5/16 CLEAR PVC TUBING - Available per .
S142058-VS 1/4-20 X 5/8 PHIL TRUSS MACHINE SCREW 18-8
W/#516 VIBRASEAL ORANGE PATCH
S5161812 5/16-18 x 1/2 Phil Pan 18-8
SSA14 SS304 MALE/FEMALE ADAPTOR 1/4 NPT X 1/4 NPT
SSAXLE14 14 ½” long with the 5/8” diameter bar & 2 through
holes with countersinks beveled ends
SEL14M STAINLESS ELBOW 1/4IN MPT X 1/4IN MPT
SSC38 WORM GEAR CLAMP, S/S (.25-.63)
SSP12 STAINLESS STEEL AXLE PLATE - 2.5 inch X 1 inch - 2
HOLE
STR38-IL IN LINE STRAINER 3/8 BARB 20 MESH 304 STAINLESS
EDPM GSKT
TANK-10N-IN NATURAL 10 GALLON TANK WITH SIDE INSERTS
TW916 1/2 INT TOOTH L/W 410SS
W15 NONMARKING WHEEL FOR PORTABLE UNITS
WS-20CFM TSUNAMI WATER SEPARATOR 20 CFM

TIMER ADJUSTMENT INSTRUCTIONS
Page 1 of 1 | 20221202
Item Number: TR120MF | Applicaon: FOG/MIST UNITS
The TR120MF is a mulfuncon mer.
1. The four switches in the top le (Funcon) control the mer mode. For fogging/misng applicaons,
switches A, C, and D should be ON, and switch B should be OFF. This puts the mer in Dual Mode.
2. The six switches in the boom le (Time Base) control the me interval. The mer is factory set to
MINUTES. To change the Time Base to seconds or hours, refer to the chart below.
3. The ve switches in the top right (Dual Mode t1) control the delay me.
4. The ve switches in the the boom right (Dual Mode t2) control the run me. The acve me for each
funcon is equal to the combined values of any switch(es) that are ON.
NOTICE: the mer is factory set at 2 minute delay, 8 minute run me.
Timer Seng Example
In this example, the delay me has
been set to 5 minutes, and the run
me has been set to 20 minutes.
1. The FUNCTION is set to Dual
Mode.
2. The TIME BASE is set to
minutes.
3. The total DELAY me is 5
(1+4=5)
4. The total RUN me is 20
(4+16=20)
3. DUAL MODE (t1):
These switches control
the delay time.
4. DUAL MODE (t2):
These switches control
the run time.
1. FUNCTION (A to D):
This setting puts the
time in Dual Mode.
2. TIME BASE (E to K):
Switches E, F, and G
control t1.
Switches H, J, and K
control t2.
FOAMit
PN:TR120MF
A
B
C
D
E
F
G
H
J
K
FUNCTIONTIME BASE
ON OFF ON
TIME DELAY
DUAL
MODE
1
2
4
8
16
1
2
4
8
16
t1
t2
1
2
4
8
16
32
64
128
256
512
SINGLE
MODE (t)
COMBINE FOR
TOTAL TIME
SEE CHART ON SIDE
FOR FUNCTION &
TIME BASE SETUP
GRN-POWER ON
RED-RELAY ON
This manual suits for next models
2
Table of contents
Other Foamit Paint Sprayer manuals

Foamit
Foamit SP-10N User manual

Foamit
Foamit FI-5N-SM User manual

Foamit
Foamit TU-20N User manual

Foamit
Foamit SP1.5L User manual

Foamit
Foamit FG-10N-2 User manual

Foamit
Foamit SP-BP-10N User manual

Foamit
Foamit FI-25N User manual

Foamit
Foamit FI-10N User manual

Foamit
Foamit SP-WALL User manual

Foamit
Foamit F5.0L User manual