FS S5800-48MBQ User manual

ID MGMT SYS
CON
ETH
S5800-48MBQ
21
43
65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 5049 5251 5353
40G 40GEBreakout
1 2 3 4
V1.0
S5800-48MBQ
MANAGED L3 MULTIGIGABIT SWITCH
MANAGED L3 MULTI-GIGABIT SWITCH
SWITCH MULTI-GIGABIT GÉRÉ L3
Quick Start Guide
Quick-Start Anleitung
Guide de Démarrage Rapide

ID MGMT SYS
CON
ETH
S5800-48MBQ
21
43
65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 5049 5251 5353
40G 40GEBreakout 1 2 3 4
1
EN
Introduction
Accessories
Grounding Cable x1
Power Cord x2
Rubber Pad x4 M4 Screw x12
Console Cable x1
Thank you for choosing S5800-48MBQ switch. This guide is designed to familiarize you with the layout
of the switch and describes how to deploy the switch in your network.
Cat5e Cable x1
Mounting Bracket x2
S5800-48MBQ

2
EN
Hardware Overview
Front Panel Ports
Ports Description
CON
ETH
RJ45
QSFP+
An RJ45 console port for serial management
An Ethernet management port
100/1000/2500BASE-T ports for Ethernet connection
QSFP+ ports for 40G transceivers
SFP28 SFP28 ports for 10G/25G transceivers
RJ45ETH
CON
QSFP+ SFP28
Front Panel LEDs
O
Blue
Amber
O
Green
LEDs Status Description
ID indication function enable.
ID
SYS
ETH
ID indication function disable.
System is running normally.
System occurs alarm or error.
No power or no system runs or runs abnormally.
Port is receiving or transmitting packets.
Port is linked.
Green
Blinking Green
O Port is not linked.
ID MGMT SYS
CON
ETH
S5800-48MBQ
21
43
65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 5049 5251 5353
40G 40GE Breakout 1 2 3 4
ID MGMT SYS
CON
ETH
S5800-48MBQ
21
43
65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 5049 5251 5353
40G 40GE Breakout 1 2 3 4
ID
SYS RJ45 QSFP+ SFP28
MGMT

3
ENEN
Back Panel
4 Hot-swappable Fans
Blinking Green
Green
Blinking Amber
O
Green
LEDs Status Description
Port is linked at 2.5G.
RJ45
QSFP+
SFP28
Packets are receiving or transmitting at 2.5G.
Port is linked at 100M/1000M.
Packets are receiving or transmitting at 100M/1000M.
Port is not linked.
Packets are receiving or transmitting at 40G.
Port is linked at 40G.
Amber
Blinking Green
Amber
Blinking Amber
O
Green
Port is linked at 10G.
Packets are receiving or transmitting at 10G.
Port is not linked.
Port is linked at 25G.
Blinking Green Packets are receiving or transmitting at 25G.
Amber Port is linked at 10G.
Blinking Amber Packets are receiving or transmitting at 10G.
O Port is not linked.
2 Hot-swappable Power Supplies
Gounding Point

4
EN
Installation Requirements
Phillips screwdriver.
Before you begin the installation, make sure that you have the following:
Site Environment:
M6 Screws.
Standard-sized, 19" wide rack with a minimum of 1U height available.
Category 5e or higher RJ-45 Ethernet cables, ber optical cables and console cable for connecting
the network devices.
Do not install the equipment in a dusty environment.
The installation site must be free from leaking or dripping water, heavy dew, and humidity.
Ensure rack and working platforms are well earthed.
Do not operate it in an area that exceeds an ambient temperature of 45°C.
The installation site must be well ventilated. Ensure that there is adequate air ow around the
switch.
Be sure that the switch is level and stable to avoid any hazardous conditions.
ID MGMT SYS
CON
ETH
S5800-48MBQ
21
43
65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231 33

5
EN
Rack Mounting
1. Secure the mounting brackets to the two sides of the switch with six M4 screws.
Mounting the switch
Desk Mounting
1. Attach four rubber pads to the bottom.
2. Place the chassis on a desk.
36 3837 4039 4241 4443 4645 4847 5049 5251 5353
40G 40GE Breakout
1 2 3 4
ID MGMT SYS
CON
ETH
S5800-48MBQ
21
43
65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 31

6
EN
Grounding the Switch
CAUTION: The earth connection must not be removed unless all supply connections have
been disconnected.
2. Attach the switch to the rack using four M6 screws and cage nuts.
1. Connect one end of the grounding cable to a proper earth ground, such as the rack in which the
switch is mounted.
2. Secure the grounding lug to the grounding point on the switch back panel with the washer
and screws.
34 3635 3837 4039 4241 4443 4645 4847 5049 5251 5353
40G 40GE Breakout
1 2 3 4
ID MGMT SYS
CON
ETH
S5800-48MBQ
21
43
65 87 109 1211 1413 1615 1817 2019 21

7
Connecting the Power
1. Plug the AC power cord into the power port on the back of the switch.
2. Connect the other end of the power cord to an AC power source.
Connecting the RJ45 Ports
1. Connect an Ethernet cable to the RJ45 port of a computer, printer, network storage, or other
network devices.
2. Connect the other end of the Ethernet cable to the RJ45 port of the switch.
WARNING: Do not install power cable while the power is on.
EN
2625 2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 5049 5251 5353
40G 40GE Breakout
1 2 3 4
ID MGMT SYS
CON
ETH
S5800-48MBQ
21
43
65 87 109 1211 1413 1615 1817 2019 21

8
1. Plug the compatible QSFP+ transceiver into the QSFP+ port.
2. Connect a ber optic cable to the ber transceiver, then connect the other end of the cable to
another ber device.
3. Or directly connect DAC/AOC cable to the QSFP+ port.
Connecting the QSFP+ Ports
EN
2625 2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 5049 5251 5353
40G 40GE Breakout
1 2 3 4
CAUTION: Laser beams will cause eye damage. Do not look into bores of optical modules
or optical bers without eye protection.

9
Connecting the SFP28 Ports
1. Plug the compatible SFP28 transceiver into the SFP28 port.
2. Connect a ber optic cable to the ber transceiver, then connect the other end of the cable to
another ber device.
3. Or directly connect DAC/AOC cable to the QSFP28 port.
EN
2625 2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 5049 5251 5353
40G 40GE Breakout
1 2 3 4
CAUTION: Laser beams will cause eye damage. Do not look into bores of optical modules
or optical bers without eye protection.

10
Connecting the Console Port
1. Insert the RJ45 connector of the console cable into the RJ45 console port on the front of the switch.
2. Connect the other end of the console cable to the RS-232 serial port on the computer.
ID MGMT SYS
CON
ETH
S5800-48MBQ
21
43
65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231 3433 3635 3837 39
Connecting the ETH Port
1. Connect one end of a standard RJ45 Ethernet cable to a computer.
2. Connect the other end of the cable to the ETH port on the front of the switch.
Connecting the Management Ports
EN
ID MGMT SYS
CON
ETH
S5800-48MBQ
21
43
65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231 3433 35

44 4645 4847 5049 5251 5353
40G 40GEBreakout
1 2 3 4
4039 4241 4443 4645 4847 5049 5251 5353
40G 40GE Breakout
1 2 3 4
11
Conguring the Switch
Conguring the Switch Using the Web-based Interface
Step1: Connect the computer to the Management port of the switch using the network cable.
Step 2: Set the IP address of the computer to 192.168.1.x. ("x" is any number from 2 to 254.). Set the
subnet mask of the computer to 255.255.255.0.
Step 3: Open a browser, type http://192.168.1.1, and enter the default username and password,
admin/admin.
Step 4: Click sign in to display the web-based conguration page.
EN
?x
OK Cancel
General
IP address:
Subnet mask:
Default gateway:
You can get IP settings assigned automatically if your network
supports this capability. Otherwise, you need to ask your network
administrator for the appropriate IP settings.
Internet Protocol Version 4(TCP/IPv4) Properties
Use the following IP address:
Obtain an IP address automatically
Preferred DNS server:
Alternate DNS server:
Validate settings upon exit Advanced...
. . . 21168192
0255
255255
. . .
. . .
. . .
. . .
Obtain DNS server address automatically
Use the following DNS server addresses:

12
Conguring the Switch Using the Console Port
Step 1: Connect a computer to the switch's console port using the supplied console cable.
Step 2: Start the terminal simulation software such as HyperTerminal on the computer.
Step 3: Set the parameters of the HyperTerminal: 115200 bits per second, 8 data bits, no parity,
1 stop bit and no ow control.
Step 4: Enter the default username and password, admin/admin.
x
Quick Connect
Protocol: Serial
Flow Control
DTR/DSR
RTS/CTS
XON/XOFF
Save sessionShow quick connect on startup
Open in a tab
Connect Cancel
COM3
115200
8
None
1
Port:
Baud rate:
Data bits:
Parity:
Stop bits:
Name of pipe:
EN

13
Troubleshooting
Loading Failure Troubleshooting
After loading fails, the system will keep running in the original version. At this time, users should
re-check if physical port connections are good rstly. If some ports are not connected, then
re-connect them to ensure that physical connections are correct, and begin re-loading. If physical
connections are correct, then check the loading process information displayed on the super terminal
to verify if there are input errors. If there are input errors, correct them and re-load.
If system password is lost or forgotten, the following method can be used to reset the password:
1. Connect the console port of the switch to the computer through the console cable.
2. Press ctrl + b to enter the Uboot mode.
3. Start the system with an empty conguration le with no password.
Bootrom#boot_ash_nopass
Bootrom#Do you want to revert to the default cong le?[Y|N|E]:
1. Make sure the power supply is normal and the console cable is properly connected.
2. Check if the console cable is the right type.
3. Check if the control cable driver is properly installed on the computer.
4. Ensure the parameters of the HyperTerminal are correct.
User Password Lost Troubleshooting
Conguration System Troubleshooting
EN
NOTE: Forgetting your username and password and restoring them through console port
may cause conguration loss and business interruption. Please remember your username
and password.

14
EN
Support and Other Resources
Download
Help Center
Contact Us
https://www.fs.com/download.html
https://www.fs.com/service/help_center.html
https://www.fs.com/contact_us.html
Product Warranty
FS ensures our customers that any damage or faulty items due to our workmanship, we will oer a
free return within 30 Days from the day you receive your goods. This excludes any custom made
items or tailored solutions.
Warranty: S5800-48MBQ Switch enjoys 5 years limited warranty against defect in materials
or workmanship. For more details about warranty, please check at
https://www.fs.com/policies/warranty.html
Return: If you want to return item(s), information on how to return can be found at
https://www.fs.com/policies/day_return_policy.html
5

ID MGMT SYS
CON
ETH
S5800-48MBQ
21
43
65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 5049 5251 5353
40G 40GEBreakout 1 2 3 4
15
Einführung
Zubehör
Erdungskabel x1
Netzkabel x2
Gummipad x4 M4-Schrauben x12
Konsolenkabel x1
Vielen Dank, dass Sie sich für den Switch S5800-48MBQ entschieden haben. Diese Anleitung soll Sie
mit dem Aufbau des Switches vertraut machen und beschreibt, wie Sie den Switch in Ihrem Netzwerk
einsetzen.
Cat5e-Kabel x1
Montagebügel x2
S5800-48MBQ
DE

16
Hardware-Übersicht
Ports an der Vorderseite
Ports Beschreibung
CON
ETH
RJ45
QSFP+
Ein RJ45-Konsolenanschluss für die serielle Verwaltung
Ein Ethernet-Verwaltungsanschluss
100/1000/2500BASE-T-Ports für Ethernet-Anschluss
QSFP+-Ports für 40G-Transceiver
SFP28 SFP28-Ports für 10G/25G-Transceiver
RJ45ETH
CON
QSFP+ SFP28
LEDs an der Vorderseite
Aus
Blau
Orange
Aus
Grün
LEDs Status Beschreibung
ID-Anzeigefunktion aktiviert.
ID
SYS
ETH
ID-Anzeigefunktion deaktiviert.
Das System läuft normal.
Auf dem System ist ein Alarm oder Fehler aufgetreten.
Kein Strom oder das System läuft abnormal.
Port empfängt oder sendet Pakete.
Port ist verbunden.
Grün
Blinkt Grün
Aus Port ist nicht verbunden.
ID MGMT SYS
CON
ETH
S5800-48MBQ
21
43
65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 5049 5251 5353
40G 40GE Breakout 1 2 3 4
ID MGMT SYS
CON
ETH
S5800-48MBQ
21
43
65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231 3433 3635 3837 4039 4241 4443 4645 4847 5049 5251 5353
40G 40GE Breakout 1 2 3 4
ID
SYS RJ45 QSFP+ SFP28
MGMT
DE

17
Rückseite
4 Hot-swap-fähige Lüfter
Blinkt Grün
Grün
Blinkt Orange
LEDs Status Beschreibung
Port ist mit 2,5G verbunden.
RJ45
Pakete werden mit 2,5G empfangen oder gesendet.
Port ist mit 100M/1000M verbunden.
Es werden Pakete mit 100M/1000M empfangen oder
gesendet.
Orange
Aus
Grün
QSFP+
SFP28
Port ist nicht verbunden.
Es werden Pakete mit 40G empfangen oder gesendet.
Der Port ist mit 40G verbunden.
Blinkt Grün
Orange
Blinkt Orange
Aus
Grün
Der Port ist mit 10G verbunden.
Es werden Pakete mit 10G empfangen oder gesendet.
Port ist nicht verbunden.
Port ist mit 25G verbunden.
Blinkt Grün Es werden Pakete mit 25G empfangen oder gesendet.
Orange Port ist mit 10G verbunden.
Blinkt Orange Es werden Pakete mit 10G empfangen oder gesendet.
Aus Port ist nicht verlinkt.
2 Hot-swap-fähige Stromversorgungen
Erdungspunkt
DE

18
Installationsvoraussetzungen
Kreuzschlitzschraubendreher.
Bevor Sie mit der Installation beginnen, stellen Sie sicher, dass Sie
Folgendes haben:
Umgebungsbedingungen:
M6-Schrauben.
Standardgroßes, 19" breites Rack mit einer Mindesthöhe von 1 HE verfügbar.
RJ-45-Ethernet-Kabel der Kategorie 5e oder höher, Glasfaserkabel und Konsolenkabel für den
Anschluss der Netzwerkgeräte.
Installieren Sie das Gerät nicht in einer staubigen Umgebung.
Der Installationsort muss frei von austretendem oder tropfendem Wasser, starkem Tau und
Feuchtigkeit sein. Stellen Sie sicher, dass Gestell und Arbeitsbühnen gut geerdet sind.
Betreiben Sie das Gerät nicht in einem Bereich, der eine Umgebungstemperatur von 45°C
überschreitet.
Der Installationsort muss gut belüftet sein. Stellen Sie sicher, dass um den Switch herum ein
ausreichender Luftstrom vorhanden ist.
Stellen Sie sicher, dass der Switch eben und stabil ist, um gefährliche Bedingungen zu vermeiden.
DE
ID MGMT SYS
CON
ETH
S5800-48MBQ
21
43
65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 3231 33

19
Rack-Montage
1. Befestigen Sie die Montagehalterungen mit sechs M4-Schrauben an den beiden Seiten des Switches.
Montage des Switch
Montage auf einem Tisch
1. Befestigen Sie vier Gummipads an der Unterseite.
2. Stellen Sie das Chassis auf den Tisch.
36 3837 4039 4241 4443 4645 4847 5049 5251 5353
40G 40GE Breakout
1 2 3 4
DE
ID MGMT SYS
CON
ETH
S5800-48MBQ
21
43
65 87 109 1211 1413 1615 1817 2019 2221 2423 2625 2827 3029 31
This manual suits for next models
1
Table of contents
Languages:
Other FS Switch manuals

FS
FS S5810 Series User manual

FS
FS S5850-24S2C-DC User manual

FS
FS S1900-16TP User manual

FS
FS N Series User manual

FS
FS S3400-24T4SP User manual

FS
FS S5900-24S4T2Q Quick guide

FS
FS PoE+ Series User manual

FS
FS S5500-48T8SP User manual

FS
FS S3700-24T4F Instruction Manual

FS
FS Fiberstore S8050-20Q4C User manual