Gallagher TW-1 User manual

1
English
Contents
Box contents ............................................................... 1
Charging the baery ................................................... 2
Understanding the TW-Weighing Unit...................... 3
Installaon .................................................................. 4
Connecng equipment to the TW-........................... 6
Specificaons .............................................................. 6
First me start-up ....................................................... 7
Start a session............................................................. 8
View animal informaon........................................... 10
Care and maintenance.............................................. 11
Connecng the TW-to a computer ......................... 11
Approvals and standards........................................... 12
BOX CONTENTS
The Gallagher TW-box contains:
• Carry Bag
• TW-weighing unit
• 110V - 230V Mains AC adapter
• USB cable
• USB flash drive
• 12V baery cable with alligator clips
• Mini Serial Adapter (2M1709)
• Mounng bracket and mounng hardware
TW-1
QUICK START GUIDE
Thank you for purchasing the Gallagher TW-Weigh Scale unit. The Gallagher
range of weighing systems is simple, tough, innovave and reliable.
BONUS OFFER
Register your product online at www.gallagherams.com to extend your
warranty to two years for free.
Follow these instrucons for the setup and first use of the TW-.
Further informaon can be obtained by tapping when displayed on screen.

2
Gallagher TW-Weigh Scale Quick Start Guide
English
SPECIFICATIONS
Operang Temperature -20oto 50oC
-5oto 120oF
Environmental Protecon Rang IP67
Input Voltage 12 V DC
Esmated baery run me 16 hours at 60% brightness
12 hours at 100% brightness
CHARGING THE BATTERY
To ensure opmum performance of the TW-, the internal baery may need to be
charged for up to 16 hours before first me use.
Important: If the TW-is to be stored for an extended period, this should be in
a cool dry place with a fully charged baery.
Always charge the baery indoors.
1. Connect the power adapter at the base of the unit and plug the TW-into a
power outlet and switch ON. The charging icon will display on the screen.
Warning: The power adaptor is intended for indoor use only. Do not expose to
rain or dampness.
2. When the charge shows 100% the TW-is ready to use with or without the
power adapter.
Note:
• When the TW-is in use, the baery icon
will display and show remaining charge.
• When using the scale and the charge level falls below 10%, the baery icon
will flash with a red outline. You will have about 30 minutes to complete the
weighing session before the TW-must be charged. When the charge level
becomes crical the unit will shut down.
• To check remaining run me at current sengs, from the Home screen, go to
Sengs > About > Baery.
• The baery error icon will display if the baery is too hot (above +45oC)
or too cold (below 0oC). The Scale will keep operang while plugged in
but will not charge properly unl at room temperature.

3
Gallagher TW-Weigh Scale Quick Start Guide
English
UNDERSTANDING THE TW-1 WEIGHING UNIT
Footer bar detail
Loadbar connecons
USB port
(for memory sck)
Serial port
(mini adapter supplied to
change connector sex)
USB port
(connect to PC)
Baery charger
WiFi status
Bluetooth status Baery charge indicator
Weighing mode
AUTO - Automac weight lock
MAN - Manual weight lock
Touch Screen
Tap the screen icons,
field names or buons
to view or enter data.
Weigh buon
Records animal weight
Zero buon
Sets the displayed
weight to zero.
Home Buon
Return to the
Home screen
Power buon
Turn TW-1 On/Off
Find animal
Look up and add animal to
a session
Backspace/DeleteChange mode from numeric
to alpha text entry Space bar
Navigaon keys
These buons can be
used to navigate the
funcons of the scale
as an alternave to the
touch screen.
Footer bar
On-screen Help
Touch to display
informaon about
the current screen
Remove animal
Weigh screen
Connecons

4
Gallagher TW-Weigh Scale Quick Start Guide
English
INSTALLATION
Installing the TW-
The TW-can be placed on a table top or mounted
on the bracket supplied.
Installing the Scale bracket
The bracket can be mounted on a flat vercal surface, a round post, or a rail.
To mount the bracket on a flat vercal surface, or a round wooden post, use
the 4 x tek screws included with the unit.
To mount the bracket on either a vercal or horizontal bar, use the ‘U’ bolts
included with the unit.
Important:
It is not recommended to mount the TW-bracket on the weighing crate or chute
as interacon with the scale can impair weighing performance.

5
Gallagher TW-Weigh Scale Quick Start Guide
English
Installing the loadbars
If using loadbars, follow these steps:
1. Select a weighing site that provides a solid, level and well drained surface.
2. Ensure the loadbars and plaorm are well secured and clear of any
obstrucons.
3. Either bolt the loadbars to the concrete pad or locate them on studs set into
the concrete. It is important that the loadbars and plaorm sit flat without
any rocking or twisng to avoid weighing inaccuracies.
Note: It may be necessary to shim the loadbars or plaorm to ensure there
are no twisng pressures within the plaorm. Weights should be evenly
distributed over the top of the weigh bars.
4. Connect the loadbar cables to the TW-.
A beep will sound indicang a successful connecon/ disconnecon of the
loadbars.
WARNING – Do not weld the loadbars or any structure that they are
aached to. Loadbars contain sensive electronic devices which will be
damaged by welding. Damage caused by welding will void warranty.
Position the TW-:
• clear of the plaorm to ensure it does not interfere with the flow of
animals during the weighing cycle
• within easy reach of the loadbar leads
• within easy reach of the operator (for manual weighing)

6
Gallagher TW-Weigh Scale Quick Start Guide
English
FIRST TIME START-UP
The first me the TW-is powered on, the First Time Start-Up screen will display.
Tap the screen to update the language, me, date and weight fields as required
and then tap Save.
To change any of these sengs later, they can be accessed via Sengs on the
right of the Home screen.
For more informaon about this screen or any TW-screen, tap displayed in
the top right corner of the screen. This will display the On-screen Help with more
informaon about what you see on the screen.
Note: The navigaon keys on the keypad can be used at any me to select the
TW-1 funcons, as an alternave to the touch screen.
Auto Shutdown
When the TW-is leidle for more than 30 minutes it will automacally shutdown
to preserve the baery.
Press the Power buon to turn the unit back on.
Note: When the baery charger is connected, the TW-1 will not shutdown aer
the inacvity period. The screen will remain acve.

7
Gallagher TW-Weigh Scale Quick Start Guide
English
CONNECTING EQUIPMENT TO THE TW-1
Connecting to an EID Reader
The EID Reader can be connected to the TW-by either a serial cable or via
Bluetooth®.
1. Turn On the EID Reader.
2. Turn On the TW-.
3. On the TW-, tap Sengs > Equipment Connecons > EID Reader.
4. Select how the Reader is being connected, either via Bluetooth or using a
serial cable.
Note: A mini serial adapter is included with the TW-if a female serial
connecon is required.
Important: The TW-can also be connected to via Bluetooth as a “Slave”,
by iniang the connecon from the reader. A passcode of “0000” may be
required to complete this connecon.
Refer to Bluetooth – Connect EID Reader in the TW-1 On-screen Help or your EID
Reader User Manual for further informaon on pairing the reader.
Connecting to a Drafter/Sorter
To connect the TW-to a draer, use the data cables suppled with your draer.
Refer to your Draer User Manual for more informaon.
1. Turn On the TW-.
2. On the TW-, tap Sengs > Equipment Connecons > Draer.
3. Specify the type of draer that is being connected, to complete the setup.
If your draer is not listed, tap Create Custom and follow the configuraon
wizard set up your draer.

8
Gallagher TW-Weigh Scale Quick Start Guide
English
START A SESSION
When you gather informaon about an animal, it is recorded in a Session. Each
event such as weighing, adds a record to the current session.
A template using pre-determined defaults can be set up and used each me you
start a new session.
Note: It is recommended a new session is opened for a new day’s acvity or for a
new group of animals. An animal cannot appear within the same session more than
once.
To start a new session:
1. From the Home screen, tap New . The New Session screen is displayed.
2. Tap Quick Start to open the Weigh screen with the scale default sengs.
Note: To set up and use templates, refer to the TW-1 On-Screen Help.
Important: Before weighing, 0.0 should be displayed. If not, press .
1. Load the animal onto the plaorm.
2. If required, you can record the animal’s Visual Tag Number or scan an
Electronic ID.
3. If weighing in AUTO - Automac weight lock, the scale will lock on to the
weight and hold it on the screen unl the animal leaves the plaorm.
If weighing in MAN - Manual weight lock, you must first press Weigh .
When the weight becomes stable, it will lock.
4. Move the animal offthe plaorm.
Important: If the weight displayed does not always return to 0.0 aer weighing,
check for dirt or manure that may have been leon the plaorm.
The TW-can be re-zeroed by pressing .
Reminder: For more informaon about this screen or any TW-screen, tap
displayed in the top right corner of the screen.
To customize the session:
click on the Opons buon
at the lower leof the
screen. Here you can set up
the weighing mode, draing
opons and name for the
session. Refer to Session
Opons (p. 9) for more
informaon.

9
Gallagher TW-Weigh Scale Quick Start Guide
English
Notes:
• When the weight locks, there will be a beep (if turned on in Sengs) and a
red light above the Weigh buon displays briefly.
• Other informaon, for example: Notes, can be entered once the weight has
locked or an ID has been entered.
• In either mode, you can re-weigh an animal by pressing Weigh aer a
successful weight lock.
• If draing is turned on, the gate number and group will display, in top
right corner of the screen, indicang the draing category. Tap this box to
override the draing decision.
• By default the scale will automacally zero any debris leon the plaorm
between 2-5kg depending on the capacity of your loadbars. This can be
altered in the connected loadbar sengs.
Session Options
The Sessions Opons menu is used to configure sengs for the current session.
1. From this screen you can change the session name, turn draing On or Off,
change the weight lock mode and configure Advanced sengs.
2. Tap Save to keep any changes.
View the On-Screen Help for more informaon about each draing opon and
the Advanced sengs.

10
Gallagher TW-Weigh Scale Quick Start Guide
English
VIEW ANIMAL INFORMATION
The informaon collected during a session can be viewed from the session’s
Weigh screen.
To view informaon about
all the animals in the
session;
tap All Animals,
tap .
Tap to view weight range
of animals.
To view informaon about an
individual animal weighed;
tap .
Tap an animal VID to view this
animal on the Weigh screen.
Tap to view the history
of weights for the selected
animal, from the Weigh
screen.

11
Gallagher TW-Weigh Scale Quick Start Guide
English
CARE AND MAINTENANCE
The TW-is a tough and reliable product designed for use in typical livestock
environments. Proper care and maintenance can extend its life.
Listed below are guidelines for keeping the TW-in good condion.
• Do not submerge the TW-in any liquid.
• Store in a cool, dry place. Avoid storing in direct sunlight.
• Aer use, clean with a damp cloth. Take care not to scratch the display.
• If storing the TW-1 for a long me, store with the baery charged.
Soware Updates
It is important to update the TW-soware from me to me to ensure you have
the latest enhancements. Updates are regularly released to enhance the features
of the scale or to correct issues. These updates can be accessed by signing into
Gallagher Animal Performance on your PC:
hps://am.app.gallagher.com/amc/dashboard
1. Select Soware ( ) from the Animal Performance navigaon pane.
2. Follow the on-screen instrucons, and select the device to be upgraded.
3. Press Download to begin the soware update for your selected device.
4. The soware upgrade file will be saved to your Downloads folder. Copy it to
a USB flash drive.
5. Turn offthe TW-and Insert the USB flash drive.
6. Turn on the TW-. The USB sck is recognised and the upgrade process begins.
7. Follow the instrucons on the screen to complete the update.
TRANSFER SESSION DATA
Download the Gallagher Animal Performance app from Google Play or the App Store.
If required, follow the prompts and create a Gallagher Account.
• On the TW-1, press the Synchronise icon on the Home screen.
Note: The first me you sync data from the TW-1 you will be prompted to
enter your registraon credenals on the scale.
• The Syncing process will automacally begin and any differences in session and
animal data on the TW-1 or in Gallagher Animal Performance, will be updated.
Aer syncing, the same data will be present on the TW-1 and Animal Performance.
• To view your animal data, open the Gallagher Animal Performance Mobile App
and sync your data or login to the Gallagher Animal Performance Web App:
hps://am.app.gallagher.com/amc/dashboard

12
Gallagher TW-Weigh Scale Quick Start Guide
English
APPROVALS AND STANDARDS
This symbol on the product or its packaging indicates that this product must not be
disposed of with other waste. Instead, it is your responsibility to dispose of your waste
equipment by handing it over to a designated collecon point for the recycling of waste
electrical and electronic equipment. The separate collecon and recycling of your waste
equipment at the me of disposal will help conserve natural resources and ensure that
it is recycled in a manner that protects human health and the environment. For more
informaon about where you can drop offyour waste equipment for recycling, please
contact your local city recycling office or the dealer from whom you purchased the
product.
FCC This device complies with part 15 of the FCC Rules. Operaon is subject to the following two
condions: (1) this device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operaon.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protecon against harmful interference in a residenal installaon. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instrucons, may cause harmful interference to radio communicaons.
However, there is no guarantee that interference will not occur in a parcular installaon.
If this equipment does cause harmful interference to radio or television recepon, which can
be determined by turning the equipment offand on, the user is encouraged to try to correct
the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separaon between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Cauon: Changes or modificaons not expressly approved by Gallagher Group Limited could
void the user’s authority to operate the equipment.
Industry
Canada
This device complies with Industry Canada licence-exempt RSS standard(s). Operaon is
subject to the following two condions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired
operaon of the device.
Under Industry Canada regulaons, this radio transmier may only operate using an antenna
of a type and maximum (or lesser) gain approved for the transmier by Industry Canada.
To reduce potenal radio interference to other users, the antenna type and its gain should
be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that
necessary for successful communicaon.
This radio transmier (IC: 7369A-G0260X) has been approved by Industry Canada to operate
with the antenna types listed below with the maximum permissible gain and required
antenna impedance for each antenna type indicated. Antenna types not included in this list,
having a gain greater than the maximum gain indicated for that type, are strictly prohibited
for use with this device.
Antenna Types:
- BR600 Small Antenna Panel (G03121)
- BR1300 Large Antenna Panel (G031424)
- Sheep Auto Draer Antenna Panel (G05714)
The Bluetooth® word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc. and any use by
Gallagher Group Limited is under license. Other trademarks and trade names are those of their respecve owners.

13
Nederlands
Inhoud
Inhoud van de doos .................................................. 95
Specificaes .............................................................. 96
De baerij opladen ................................................... 96
Informae over de TW-1 weegeenheid .................... 97
Monteren.................................................................. 98
Eerste keer opstarten.............................................. 100
Apparatuur op de TW-1 aansluiten ........................ 101
Een sessie starten ................................................... 102
Dierinformae bekijken .......................................... 104
Zorg en onderhoud ................................................. 105
De TW-1 verbinden met een computer .................. 105
Toelangen en normen........................................... 106
INHOUD VAN DE DOOS
De doos van de Gallagher TW-1 bevat:
• Draagtas
• TW-1 weegeenheid
• AC-adapter voor 110-230 V
• USB-kabel
• USB-flashdrive
• 12 V baerijkabel met krokodillenklemmen
• Seriële mini-adapter (2M1709)
• Montagebeugel en montagehulpmiddelen
TW-1
SNELSTARTGIDS
Bedankt voor uw aanschaf van de Gallagher TW-1 weegschaaleenheid. De
serie weegsystemen van Gallagher is eenvoudig, duurzaam, innovaef en
betrouwbaar.
BONUSAANBIEDING
Registreer uw product online op www.gallagherams.com om uw
garane gras naar twee jaar te verlengen.
Volg deze instruces voor het instellen en het eerste gebruik van de TW-1.
Meer informae is beschikbaar door op te kken als dit vraagteken op het
scherm staat.

14
Gallagher TW-weegschaal Snelstartgids
Nederlands
SPECIFICATIES
Bedrijfstemperatuur -20otot 50oC
-5otot 120oF
Omgevingsbeschermingsklasse IP67
Ingangsspanning 12 V DC
Geschae bedrijfsjd baerij 16 uur bij 60% helderheid
12 uur bij 100% helderheid
DE BATTERIJ OPLADEN
Voor een opmale werking van de TW-1 moet de interne baerij vóór het eerste
gebruik 16 uur worden opgeladen.
Belangrijk: Als de TW-1 langere jd moet worden opgeslagen, moet de ruimte
daarvoor koel en droog zijn en moet de baerij volledig zijn opgeladen.
De baerij aljd binnen opladen.
1. Sluit de netvoedingadapter aan op de basis van de eenheid, steek de stekker
van de TW-1 in een stopcontact en zet het apparaat AAN. Het pictogram voor
opladen verschijnt op het scherm.
Waarschuwing: De voedingsadapter is alleen bedoeld voor gebruik
binnenhuis. Niet blootstellen aan regen of vocht.
2. Als het opladen 100% aangee, is de TW-1 klaar voor gebruik met of zonder de
netvoedingadapter.
Opmerking:
• Bij gebruik van de TW-1 verschijnt het baerij-pictogram en
toont hoe ver de baerij is opgeladen.
• Als de weegschaal in gebruik is en het oplaadniveau tot onder 10% daalt, gaat
het baerij-pictogram rood knipperen. U hebt ongeveer 30 minuten de jd
om de weegsessie af te maken. Daarna moet de TW-1 worden opgeladen.
• Als het oplaadniveau kriek wordt, schakelt de eenheid uit.
• Voor het controleren van de resterende bedrijfsjd bij de huidige instellingen
gaat u in het Home-scherm naar Instellingen > Over > Baerij.
• Het pictogram van een baerijfout wordt getoond als de baerij te warm
(boven 45 °C) of te koud (onder 0 °C) is. De schaal zal blijven werken als hij
aangesloten is maar zal pas bij kamertemperatuur normaal opladen.

15
Gallagher TW-weegschaal Snelstartgids
Nederlands
INFORMATIE OVER DE TW-1 WEEGEENHEID
Detail voeekstbalk
Weegbalkaansluingen
USB-poort
(voor geheugensck)
Seriële poort
(meegeleverde mini-adapter voor
wijzigen geslacht connector)
USB-poort
(aansluiten op pc)
Baerijlader
Status WiFi
Status Bluetooth Laadindicator baerij
Weegstand
AUTO - Automasche
gewichtsvergrendeling
MAN - Handmage
gewichtsvergrendeling
Aanraakscherm
Tik op de
schermpictogrammen,
veldnamen of
knoppen om gegevens
te bekijken of in te
voeren.
Weegknop
Legt het gewicht van
het dier vast.
Resetknop
Zet het weergegeven
gewicht op nul.
Home-knop
Terug naar het
Home-scherm
Power-knop
TW-1 in-/uitschakelen
Dier zoeken
Een dier opzoeken en aan
een sessie toevoegen
Backspace/DeleteModus wijzigen teksnvoer
van numeriek naar alfa Spaebalk
Navigaetoetsen
Deze knoppen kunt
u gebruiken om
door de funces van
de weegschaal te
navigeren in plaats van
het aanraakscherm te
gebruiken.
Voeekstbalk
Ingebouwde
helpfunce
Aanraken om
informae over het
huidige scherm weer
te geven.
Dier verwijderen
Weegscherm
Aansluingen

16
Gallagher TW-weegschaal Snelstartgids
Nederlands
MONTEREN
De TW-1 monteren
De TW-1 kan op een tafel worden geplaatst of
op de meegeleverde beugel worden gemonteerd.
De beugel van de weegschaal monteren
De beugel kan op een plat vercaal oppervlak, een ronde paal of een rail worden
gemonteerd.
Gebruik de meegeleverde 4 x teksschroeven om de beugel op een plat oppervlak
of een ronde houten paal te monteren.
Gebruik de meegeleverde ‘U’-bouten om de beugel op een vercale of
horizontale balk te monteren.
Belangrijk:
We bevelen aan om de TW-1 beugel niet op het weegkrat of de weegkooi te
monteren, aangezien de weegprestaes hierdoor kunnen verslechteren.

17
Gallagher TW-weegschaal Snelstartgids
Nederlands
De weegbalken monteren
Volg bij gebruik van weegbalken de volgende stappen:
1. Zoek een weeglocae uit met een stevige en gelijkmage ondergrond en een
goede afvoer.
2. Zorg ervoor dat de weegbalken en het plaorm stevig verankerd en vrij van
obstakels zijn.
3. Zet de weegbalken met bouten op het betonblok vast of plaats ze op pennen
in het beton. Om onnauwkeurigheid in de mengen te voorkomen, is het
belangrijk dat de weegbalken en het plaorm volstrekt horizontaal zijn
vastgezet en niet kunnen schudden of draaien.
Opmerking: Het kan nodig zijn de weegbalken of het plaorm op te vullen
om er zeker van te zijn dat er geen wringspanning kan ontstaan. Het gewicht
dient gelijkmag te worden verspreid over de bovenkant van de weegbalken.
4. Sluit de kabels van de weegbalken aan op de TW-1.
Er wordt een piep afgegeven om aan te geven of het aansluiten/ontkoppelen
van de weegbalken gelukt is.
WAARSCHUWING - de weegbalken of een construce waarop deze
zijn bevesgd nooit lassen. De weegbalken zijn voorzien van gevoelige
elektronische apparaatjes die bij lassen kunnen beschadigen.
Bij beschadiging als gevolg van lassen komt de garane te vervallen.
De TW-1 plaatsen:
• op afstand van het plaorm om er zeker van te zijn dat de stroom dieren
jdens de weegcyclus niet wordt verstoord
• ruim binnen bereik van de kabels van de weegbalken
• ruim binnen bereik van de operator (bij handmag wegen)

18
Gallagher TW-weegschaal Snelstartgids
Nederlands
EERSTE KEER OPSTARTEN
Bij de eerste keer opstarten van de TW-1 verschijnt het scherm Eerste keer
opstarten.
Tik op het scherm om de velden taal, jd, datum en gewicht zoals gewenst bij te
werken en k vervolgens op Opslaan.
Om deze instellingen later te wijzigen, kunt u naar Instellingen rechts in het
Home-scherm gaan.
Voor meer informae over dit scherm of een willekeurig ander scherm van de
TW-1, kt u op in de hoek rechtsboven in het scherm. Hierdoor verschijnt de
ingebouwde helpfunce met meer informae over wat u op het scherm ziet.
Opmerking: In plaats van het aanraakscherm kunt u aljd de navigaetoetsen
op het toetsenbord gebruiken om de funces van de TW-1 te selecteren.
Automatisch uitschakelen
Als u de TW-1 langer dan 30 minuten niet gebruikt, wordt deze automasch
uitgeschakeld om de baerij te sparen.
Druk op de Power-knop om de eenheid weer in te schakelen.
Opmerking: Wanneer de baerijlader is aangesloten, wordt de TW-1 niet
uitgeschakeld na de ingestelde stand-By jd. Het scherm blijacef.

19
Gallagher TW-weegschaal Snelstartgids
Nederlands
APPARATUUR OP DE TW-1 AANSLUITEN
Op een EID Reader aansluiten
De EID Reader kan met behulp van een seriële kabel of via Bluetooth® op de TW-1
worden aangesloten.
1. Schakel de EID Reader in.
2. Schakel de TW-1 in.
3. Tik op de TW-1 op Instellingen > Apparatuuraansluingen > EID
Reader.
4. Selecteer hoe de Reader wordt aangesloten, via Bluetooth of met behulp van
een seriële kabel.
Opmerking: Als een vrouwelijke seriële aansluing vereist is, wordt de TW-1
inclusief een seriële mini-adapter geleverd.
Belangrijk: Een aansluing op de TW-1 is ook mogelijk als een “Slave” via
Bluetooth door de aansluing vanaf de reader te iniëren. Om deze aansluing
te voltooien, kan het wachtwoord “0000” vereist zijn.
Zie Bluetooth – EID Reader aansluiten in de ingebouwde helpfunce van de TW-1
of uw Gebruikershandleiding EID Reader voor meer informae over het paren van
de reader.
Op een drafter/sorteerder aansluiten
Voor het aansluiten van de TW-1 op een draer gebruikt u de bij uw draer
meegeleverde datakabels. Zie uw Gebruikershandleiding Draer voor meer
informae.
1. Schakel de TW-1 in.
2. Tik op de TW-1 op Instellingen > Apparatuuraansluingen > Draer.
3. Specificeer het type draer dat moet worden aangesloten en voltooi het
instellen.
Als uw draer niet genoemd wordt, kt u op Creëer Custom en volgt u de
configuraewizard voor het instellen van uw draer.

20
Gallagher TW-weegschaal Snelstartgids
Nederlands
EEN SESSIE STARTEN
Als u informae over een dier verzamelt, wordt deze in een sessie vastgelegd. Elk
evenement (zoals wegen) voegt een record aan de huidige sessie toe.
Iedere keer dat u een nieuwe sessie begint, kunt u een template met vooraf
ingestelde standaardinstellingen gebruiken.
Opmerking: Wij bevelen aan om voor een acviteit op een nieuwe dag of voor een
nieuwe groep dieren een nieuwe sessie te openen. Een dier kan niet vaker dan één
keer in dezelfde sessie verschijnen.
Een nieuwe sessie starten:
1. Tik in het Home-scherm op Nieuw . Het scherm Nieuwe Sessie wordt
weergegeven.
2. Tik op Snelstart om het Weegscherm te openen met de standaardinstellingen.
Opmerking: Zie de ingebouwde helpfunce van de TW-1 voor nadere informae
over het instellen en gebruiken van templates.
Belangrijk: Voorafgaand aan het wegen moet 0.0 worden weergegeven. Als dat niet
het geval is, drukt u op .
1. Laat het dier op het plaorm lopen.
2. Indien gewenst kunt u het visuele tagnummer van het dier opslaan of het
elektronische oormerk scannen.
3. Bij wegen in AUTO - Automasche gewichtsvergrendeling vergrendelt de
weegschaal het gewicht en houdt dit op het scherm totdat het dier het plaorm
verlaat.
Bij wegen in MAN - Handmage gewichtsvergrendeling moet u eerst op Weeg
drukken. Als het gewicht stabiel wordt, vergrendelt het.
4. Laat het dier van het plaorm stappen.
Belangrijk: Als het weergegeven gewicht na het wegen niet aljd naar 0.0
teruggaat, moet u controleren of er vuil of mest op het plaorm is achtergebleven.
De TW-1 kan weer op nul worden gezet door te drukken op .
De sessie aanpassen:
Klik op de knop Opes
linksonder in het scherm.
Hier kunt u de weegstand,
selecteeropes en
sessienaam instellen. Zie
Sessie-opes (p. 103) voor
meer informae.
This manual suits for next models
3
Table of contents
Languages:
Other Gallagher Scale manuals

Gallagher
Gallagher DAIRY SCALE XDS5000 User guide

Gallagher
Gallagher TWR-1 User manual

Gallagher
Gallagher SmartScale 700 User manual

Gallagher
Gallagher W-0 User manual

Gallagher
Gallagher W810 User manual

Gallagher
Gallagher W-1 User manual

Gallagher
Gallagher SmartScale 600 User manual

Gallagher
Gallagher W-0 User manual

Gallagher
Gallagher SmartScale 800 User manual

Gallagher
Gallagher TWR-5 User manual