Gallagher W-1 User manual

English
1
W-1
USER GUIDE
Thank you for purchasing the Gallagher W-1 Weigh Scale unit. The Gallagher range
of weighing systems is simple, tough, innovave and reliable.
BONUS OFFER
Register your product online at www.gallagherams.com to
extend your warranty to two years for free
W-1 FEATURES
• Weigh animals using wired or wireless loadbars
• Connect EID readers to capture electronic IDs
• Record animal notes and receive alerts when
the animal is next weighed
• View animal performance weight gain and
weight distribuon graphs
• Make dradecisions based on animal weight
data or animal IDs, allowing an operator to
manually open the appropriate gate
• Synchronise animal data to the Animal
Performance web and mobile app and other
weighing devices, ensuring all data is consistent
across devices and backed up
BOX CONTENTS
The Gallagher W-1 box contains:
• W-1 weighing unit
• 110V - 230V Mains AC adapter
• 12V baery cable with alligator clips
• Mounng bracket and mounng hardware

2
Gallagher W-Weigh Scale User Guide
English
CHARGING THE BATTERY
To ensure opmum performance of the W-1, the internal baery may need to be
charged for up to 16 hours before first me use.
Important: If the W-1 is to be stored for an extended period, this should be in a
cool dry place. For opmum baery life, store the W-1 at 50% capacity. Always
charge the baery indoors.
1. Connect the power adapter at the base of the unit and plug the W-1 into a
power outlet and switch ON. The charging icon will display on the screen.
Warning: The power adaptor is intended for indoor use only. Do not expose to
rain or dampness.
2. When the charge shows 100% the W-1 is ready to use with or without the
power adapter.
Note:
• When the W-1 is in use, the baery icon will display
and show remaining charge.
• When using the scale and the charge level falls below 10%, the baery icon
will flash with a red outline. You will have about 30 minutes to complete the
weighing session before the W-1 must be charged. When the charge level
becomes crical the unit will shut down.
• To check remaining run me at current sengs, from the Home screen, go to
Sengs > About > Baery.
• The baery error icon will display if the baery is too hot (above +45oC )
or too cold (below 0oC). The Scale will keep operang while plugged in
but will not charge properly unl at room temperature.
Auto Shutdown
When the W-1 is leidle for more than 30 minutes it will automacally shutdown
to preserve the baery. Press the Power buon to turn the unit back on.
Note: When the baery charger is connected, the W-1 will not shutdown aer the
inacvity period. The screen will remain acve.

3
Gallagher W-Weigh Scale User Guide
English
UNDERSTANDING THE W-1 WEIGHING UNIT
Footer bar detail
Loadbar
connecons
Baery
charger
WiFi status
Bluetooth status Baery charge indicator
Weighing mode
AUTO - Automac weight lock
MAN - Manual weight lock
Weigh buon
Records animal
weight
Zero buon
Sets the displayed
weight to zero Home buon
Return to the
Home screen
Power buon
Turn W-1 On/Off
Find animal
Look up and add
an animal to a session
Backspace/DeleteChange mode from numeric
to alpha text entry Space bar
Navigaon buons
Use to navigate and
select a funcon
Footer bar
Remove animal
Weigh screen
Connecons
EID number
Displays the number
scanned by an EID reader
Tag/VID
The visual tag number
Notes
Record animal
notes/alerts

4
Gallagher W-Weigh Scale User Guide
English
INSTALLATION
Installing the W-1
The W-1 can be placed on a table top or mounted
on the bracket supplied.
Installing the Scale bracket
The bracket can be mounted on a flat vercal surface, a
round post, or a rail.
To mount the bracket on a flat vercal surface, or a round wooden post, use
the 4 x tek screws included with the unit.
To mount the bracket on either a vercal or horizontal bar, use the ‘U’ bolts
included with the unit.
Important:
It is not recommended to mount the W-1 bracket on the weighing crate or chute
as interacon with the scale can impair weighing performance.

5
Gallagher W-Weigh Scale User Guide
English
Installing the loadbars
1. Select a weighing site that provides a solid, level and well drained surface.
2. Ensure the loadbars and plaorm are well secured and clear of any
obstrucons.
3. Either bolt the loadbars to the concrete pad or locate them on studs set into
the concrete. It is important that the loadbars and plaorm sit flat without
any rocking or twisng to avoid weighing inaccuracies.
Note: It may be necessary to shim the loadbars or plaorm to ensure there
are no twisng pressures within the plaorm. Weights should be evenly
distributed over the top of the weigh bars.
4. For Wired Loadbars: Connect the loadbar cables to the W-1.
For Wireless Loadbars: The W-1 must be within 8-10m of the loadbars. Refer
to the Gallagher Loadbars Instrucons for further installaon informaon.
A beep will sound indicang a successful connecon/ disconnecon of the
loadbars.
WARNING – Do not weld the loadbars or any structure that they are
aached to. Loadbars contain sensive electronic devices which will be
damaged by welding. Damage caused by welding will void warranty.
Position the W-1:
• clear of the plaorm
to ensure it does not
interfere with the flow
of animals during the
weighing cycle
• within easy reach of the
loadbar leads if using
wired loadbars
• within easy reach of the
operator (for manual
weighing)

6
Gallagher W-Weigh Scale User Guide
English
FIRST TIME USING THE W-1
To navigate the W-1, use the navigaon buons. Press an arrow key to navigate to
the desired field. To select a field or enter data into a highlight field, press the OK
buon. If entering text into a field, press the OK buon when finished.
The first me the W-1 is powered on, the First Time Start-Up screen will display.
Use the navigaon buons to choose the language, me, date, and weight fields
as required. Once the field is highlighted, press OK to apply the change. Navigate to
the Save buon and press OK to save the changes.
To change any of these sengs later, they can be accessed via Sengs on the
right of the Home screen.
CONNECTING TO WI-FI
Connecng to Wi-Fi on the W-1 enables communicaon with data devices. It also
allows synchronisaon of animal data to the Animal Performance App and ensures
the W-1 can receive the latest soware updates.
1. Select Sengs > Device Sengs > Wi-Fi.
2. Ensure Enable Wi-Fi is selected.
3. Select Search. The W-1 searches for available networks.
4. Select your Wi-Fi Network and enter the Wi-Fi Password.
Hint: Its helpful to Show the password when typing. Press OK to leave
the password field to navigate to the Show buon, then select OK.
Navigate to the password field, then select OK to enter the password.
5. Select Done then Connect.

7
Gallagher W-Weigh Scale User Guide
English
CONNECTING EQUIPMENT TO THE W-1
Connecting to Wireless Loadbars
1. On the W-1, select Sengs > Equipment Connecons > Loadbars >
Wireless.
2. The W-1 will search for the loadbars. When the loadbars have been located,
navigate to select them from the list, then select Connect.
Note: As per the Wireless Loadbar Installaon instrucons, your loadbars must
be switched on and in range to display in the search list.
3. The connecon process will take up to 30 seconds while pairing occurs
between the loadbars and the W-1. Once completed, select Done.
4. Press the Home buon.
5. Create a new session by selecng New. The current weight will display as
0.0kg. If it’s not 0.0, press the Zero buon. Apply some weight to the bars to
confirm the connecon is working.
Note: Aer 15 minutes of inacvity, wireless loadbars will disconnect as W-1 goes
into sleep mode. Press Power buon and go to the Weigh screen to re-connect.
Connecting to an EID Reader
The EID Reader connects to the W-1 via Bluetooth®.
1. Turn On the EID Reader.
2. Turn On the W-1.
3. On the W-1, select Sengs > Equipment Connecons > EID Reader.
Important: You can also connect to your W-1 by iniang a Bluetooth® enabled
connecon from your reader. A passcode of “0000” may be required to
complete this connecon.
Refer to the EID Reader User Manual for further informaon on pairing the reader.
Data Device
Third party devices such as printers can be connected to receive weight
informaon. A data device can be connected by either Bluetooth® or Wi-Fi.
1. Turn On the Data Device.
2. Turn On the W-1.
3. On the W-1, select Sengs > Equipment Connecons > Data Device.

8
Gallagher W-Weigh Scale User Guide
English
START A SESSION
When you gather informaon about an animal, it is recorded in a Session. Each
event such as weighing, adds a record to the current session.
Note: It is recommended a new session is opened for a new day’s acvity or for a
new group of animals. An animal cannot appear within the same session more than
once.
To start a new session:
1. From the Home screen, select New press OK. The New Session screen
is displayed.
Important: Before weighing, 0.0 should be displayed. If not, press .
2. Load the animal onto the plaorm.
3. If required, you can record the animal’s Visual Tag Number or scan an
Electronic ID.
4. If weighing in AUTO - Automac weight lock, the scale will lock on to the
weight and hold it on the screen unl the animal leaves the plaorm.
If weighing in MAN - Manual weight lock, you must first press Weigh .
When the weight becomes stable, it will lock.
5. Move the animal offthe plaorm.
Important: If the weight displayed does not always return to 0.0 aer weighing,
check for dirt or manure that may have been leon the plaorm.
The W-1 can be re-zeroed by pressing .
Notes:
• When the weight locks, there will be a beep (if turned on in Sengs) and a red
light above the Weigh buon displays briefly.
• Notes can be entered once the weight has locked or an ID has been entered.
Highlight the Notes field and press OK to enter a new note. Press OK to save
the Note. To view or edit an exisng Note, highlight the Notes field and press
the right arrow to open the Notes screen.
To customize the session:
Select the Opons buon
at the lower leof the
screen. Here you can set up
the weighing mode, draing
opons and name for the
session. Refer to Session
Opons (p. 9) for more
informaon.

9
Gallagher W-Weigh Scale User Guide
English
• In either mode, you can re-weigh an animal by pressing Weigh aer a
successful weight lock.
• By default the scale will automacally zero any debris leon the plaorm
between 2-5kg depending on the capacity of your loadbars. This can be
altered in the connected loadbar sengs.
Session Options
The Sessions Opons menu is used to configure sengs for the current session.
1. From this screen you can change the session name, turn draing On or Off,
change the weight lock mode and configure Advanced sengs.
2. Select Save.
Drafting
Animals can be drafted into groups based on their weight, current weight gain,
overall weight gain or drafted by a pre-defined list of animals IDs.
From the Sessions Opons menu, select a draopon.
1. To draby: Weight, Current Weight Gain, Overall Weight Gain
• Enter the number of draft groups in the session and select Next.
• Change the assigned weight ranges, group names or gate numbers.
• Select Done and Save the Session options.
2. To draft by list (Animal ID)
• Enter the number of draft groups in the session and select Next.
• Draft lists previously uploaded to the scale are displayed. Select the
appropriate draft list.
Note: The draft list is created on the Animal Performance Software and
synchronised to the scale. Refer to Transfer Session Data (p. 11).
• Save the Session options.
During the session, the gate number and group will display, in the top right corner
of the weigh screen. To override the draing decision, navigate to the DraGroup
box and press OK to change the decision. Manually open the nominated gate.

10
Gallagher W-Weigh Scale User Guide
English
VIEW ANIMAL INFORMATION
The informaon collected during a session can be viewed from the session’s
Weigh screen.
To view informaon about
all the animals in the
session;
Use the navigaon arrows to
select All Animals, press OK
Select .
Select to view weight
range of animals.
To view informaon about an
individual animal weighed;
Select .
Select an animal VID to view
this animal on the Weigh
screen.
Select to view the
history of weights for the
selected animal, from the
Weigh screen.

11
Gallagher W-Weigh Scale User Guide
English
TRANSFER SESSION DATA
Synchronising enables data to be collected from and sent to mulple devices around
your farm that connect to the Animal Performance app via a cloud server.
Download the Gallagher Animal Performance app from Google Play or the App Store.
If required, follow the prompts and create a Gallagher Account.
• On the W-1, ensure Wi-Fi is connected and select the Synchronise icon on
the Home screen.
Note: The first me you sync data from the W-1 you will be prompted to
enter your registraon credenals on the scale.
• The Syncing process will automacally begin and any differences in session and
animal data on the W-1 or in Gallagher Animal Performance, will be updated.
Aer syncing, the same data will be present on the W-1 and Animal Performance.
• To view your animal data, open the Gallagher Animal Performance Mobile App
and sync your data or login to the Gallagher Animal Performance Web App:
hps://am.app.gallagher.com/amc/dashboard
CARE AND MAINTENANCE
The W-1 is a tough and reliable product designed for use in typical livestock
environments. Proper care and maintenance can extend its life.
Listed below are guidelines for keeping the W-1 in good condion.
• Do not submerge the W-1 in any liquid.
• Store in a cool, dry place. Avoid storing in direct sunlight.
• Aer use, clean with a damp cloth. Take care not to scratch the display.
SOFTWARE UPDATES
It is important to update the W-1 soware to ensure you have the latest enhancements
and bug fixes. The W-1 will automacally check for soware updates when Wi-Fi is
connected. If a new version is available, follow the onscreen instrucons to complete
the update.
SPECIFICATIONS
Operang Temperature -20oto 50oC
-5oto 120oF
Environmental Protecon Rang IP67
Input Voltage 12 V DC
Esmated baery run me 16 hours at 60% brightness
12 hours at 100% brightness

12
Gallagher W-Weigh Scale User Guide
English
APPROVALS AND STANDARDS
3E5621 06/22 Ed. 1
This symbol on the product or its packaging indicates that this product must not be
disposed of with other waste. Instead, it is your responsibility to dispose of your waste
equipment by handing it over to a designated collecon point for the recycling of waste
electrical and electronic equipment. The separate collecon and recycling of your waste
equipment at the me of disposal will help conserve natural resources and ensure that
it is recycled in a manner that protects human health and the environment. For more
informaon about where you can drop offyour waste equipment for recycling, please
contact your local city recycling office or the dealer from whom you purchased the
product.
FCC This device complies with part 15 of the FCC Rules. Operaon is subject to the following two
condions: (1) this device may not cause harmful interference, and (2) this device must accept
any interference received,including interference that may cause undesired operaon.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protecon against harmful interference in a residenal installaon. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instrucons, may cause harmful interference to radio communicaons.
However, there is no guarantee that interference will not occur in a parcular installaon.
If this equipment does cause harmful interference to radio or television recepon, which can
be determined by turning the equipment offand on, the user is encouraged to try to correct
the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separaon between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Cauon: Changes or modificaons not expressly approved by Gallagher Group Limited could
void the user’s authority to operate the equipment.
Industry
Canada
This device complies with Industry Canada licence-exempt RSS standard(s). Operaon is
subject to the following two condions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired
operaon of the device.
Under Industry Canada regulaons, this radio transmier may only operate using an antenna
of a type and maximum (or lesser) gain approved for the transmier by Industry Canada.
To reduce potenal radio interference to other users, the antenna type and its gain should
be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that
necessary for successful communicaon.
This radio transmier (IC: 7369A-G0260X) has been approved by Industry Canada to operate
with the antenna types listed below with the maximum permissible gain and required
antenna impedance for each antenna type indicated. Antenna types not included in this list,
having a gain greater than the maximum gain indicated for that type, are strictly prohibited
for use with this device.
Antenna Types:
- BR600 Small Antenna Panel (G03121)
- BR1300 Large Antenna Panel (G031424)
- Sheep Auto Draer Antenna Panel (G05714)
The Bluetooth® word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc. and any use by
Gallagher Group Limited is under license. Other trademarks and trade names are those of their respecve owners.

13
Nederlands
W-1 FUNCTIES
• Dieren wegen met behulp van bedrade of
draadloze weegbalken
• EID-lezers aansluiten om elektronische ID’s vast
te leggen
• Aantekeningen over dieren maken en
meldingen krijgen wanneer het dier de
volgende keer wordt gewogen
• Grafieken van gewichtstoename en
gewichtsverdeling van dieren bekijken
• Maak tekenbeslissingen op basis van dierenge-
wichtsgegevens of dieren-ID’s, zodat een
operator de juiste poort handmag kan openen
• Synchroniseer diergegevens met de Animal
Performance web- en mobiele app en andere
weegapparaten, zodat alle gegevens hetzelfde
zijn op alle apparaten en er een back-up van
wordt gemaakt
INHOUD VAN DE DOOS
De doos van de Gallagher W-1 bevat:
• W-1 weegeenheid
• AC-adapter voor 110-230 V
• 12 V baerijkabel met krokodillenklemmen
• Montagebeugel en montagehulpmiddelen
W-1
GEBRUIKERSHANDLEIDING
Bedankt voor uw aanschaf van de Gallagher W-1 weegschaaleenheid. De serie
weegsystemen van Gallagher is eenvoudig, duurzaam, innovaef en betrouwbaar.
BONUSAANBIEDING
Registreer uw product online op www.gallagherams.com om uw
garane gras naar twee jaar te verlengen.

14
Gebruikershandleiding Gallagher W-1 Weegschaal
Nederlands
DE BATTERIJ OPLADEN
Voor een opmale werking van de W-1 moet de interne baerij vóór het eerste
gebruik 16 uur worden opgeladen.
Belangrijk: Als de W-1 langere jd moet worden opgeslagen. Voor een opmale
levensduur van de baerij dient u de W-1 op 50% capaciteit te bewaren. De
baerij aljd binnen opladen.
1. Sluit de netvoedingadapter aan op de basis van de eenheid, steek de stekker
van de W-1 in een stopcontact en zet het apparaat AAN. Het pictogram voor
opladen verschijnt op het scherm.
Waarschuwing: De voedingsadapter is alleen bedoeld voor gebruik
binnenhuis. Niet blootstellen aan regen of vocht.
2. Als het opladen 100% aangee, is de W-1 klaar voor gebruik met of zonder de
netvoedingadapter.
Opmerking:
• Bij gebruik van de W-1 verschijnt het baerij-pictogram en
toont hoe ver de baerij is opgeladen.
• Als de weegschaal in gebruik is en het oplaadniveau tot onder 10% daalt, gaat
het baerij-pictogram rood knipperen. U hebt ongeveer 30 minuten de jd
om de weegsessie af te maken. Daarna moet de W-1 worden opgeladen.
• Als het oplaadniveau kriek wordt, schakelt de eenheid uit.
• Voor het controleren van de resterende bedrijfsjd bij de huidige instellingen
gaat u in het Home-scherm naar Instellingen > Over > Baerij.
• Het pictogram van een baerijfout wordt getoond als de baerij te warm
(boven 45 °C) of te koud (onder 0 °C) is. De schaal zal blijven werken als hij
aangesloten is maar zal pas bij kamertemperatuur normaal opladen.
Automatisch uitschakelen
Als u de W-1 langer dan 30 minuten niet gebruikt, wordt deze automasch
uitgeschakeld om de baerij te sparen. Druk op de Power-knop om de eenheid
weer in te schakelen.
Opmerking: Wanneer de baerijlader is aangesloten, wordt de W-1 niet
uitgeschakeld na de ingestelde stand-By jd. Het scherm blijacef.

15
Gebruikershandleiding Gallagher W-1 Weegschaal
Nederlands
INFORMATIE OVER DE W-1 WEEGEENHEID
Weegbalkaansluingen
Baerijlader
Detail voeekstbalk
Status WiFi
Status Bluetooth Laadindicator baerij
Weegstand
AUTO - Automasche
gewichtsvergrendeling
MAN - Handmage
gewichtsvergrendeling
Weegknop
Legt het gewicht van
het dier vast
Resetknop
Zet het weergegeven
gewicht op nul
Home-knop
Terug naar het
Home-scherm
Power-knop
W-1 in-/uitschakelen
Dier zoeken
Een dier opzoeken en
aan een sessie toevoegen
Backspace/DeleteModus wijzigen teksnvoer
van numeriek naar alfa Spaebalk
Navigaeknoppen
Gebruik om te navigeren en
een funce te selecteren
Voeekstbalk
Dier verwijderen
Weegscherm
Aansluingen
EID-nummer
Toont het nummer dat
wordt gescand door een
EID-reader
Tag/VID
Het visuele tagnummer
Noes
Neem dierenno-
es/-meldingen op

16
Gebruikershandleiding Gallagher W-1 Weegschaal
Nederlands
MONTEREN
De W-1 monteren
De W-1 kan op een tafel worden geplaatst of
op de meegeleverde beugel worden gemonteerd.
De beugel van de weegschaal monteren
De beugel kan op een plat vercaal oppervlak, een ronde paal of een rail worden
gemonteerd.
Gebruik de meegeleverde 4 x teksschroeven om de beugel op een plat oppervlak
of een ronde houten paal te monteren.
Gebruik de meegeleverde ‘U’-bouten om de beugel op een vercale of
horizontale balk te monteren.
Belangrijk:
We bevelen aan om de W-1 beugel niet op het weegkrat of de weegkooi te
monteren, aangezien de weegprestaes hierdoor kunnen verslechteren.

17
Gebruikershandleiding Gallagher W-1 Weegschaal
Nederlands
De weegbalken monteren
1. Zoek een weeglocae uit met een stevige en gelijkmage ondergrond en een
goede afvoer.
2. Zorg ervoor dat de weegbalken en het plaorm stevig verankerd en vrij van
obstakels zijn.
3. Zet de weegbalken met bouten op het betonblok vast of plaats ze op pennen
in het beton. Om onnauwkeurigheid in de mengen te voorkomen, is het
belangrijk dat de weegbalken en het plaorm volstrekt horizontaal zijn
vastgezet en niet kunnen schudden of draaien.
Opmerking: Het kan nodig zijn de weegbalken of het plaorm op te vullen
om er zeker van te zijn dat er geen wringspanning kan ontstaan. Het gewicht
dient gelijkmag te worden verspreid over de bovenkant van de weegbalken.
4. Voor bedrade weegbalken: Sluit de kabels van de weegbalken aan op de
W-1.
Voor draadloze weegbalken: De W-1 moet zich binnen een afstand van 8-10
m van de weegbalken bevinden. Zie de instruces van Gallagher-weegbalken
voor verdere installae-informae.
Er wordt een piep afgegeven om aan te geven of het aansluiten/ontkoppelen
van de weegbalken gelukt is.
WAARSCHUWING - de weegbalken of een construce waarop deze
zijn bevesgd nooit lassen. De weegbalken zijn voorzien van gevoelige
elektronische apparaatjes die bij lassen kunnen beschadigen.
Bij beschadiging als gevolg van lassen komt de garane te vervallen.
De W-1 plaatsen:
• op afstand van het
plaorm om er zeker van
te zijn dat de stroom dieren
jdens de weegcyclus niet
wordt verstoord
• binnen handbereik van de
kabels van de weegbalk
bij gebruik van bedrade
weegbalken
• ruim binnen bereik van de
operator (bij handmag
wegen)

18
Gebruikershandleiding Gallagher W-1 Weegschaal
Nederlands
EERSTE KEER DAT U DE W-1 GEBRUIKT
Gebruik om de W-1 de navigeren de navigaeknoppen. Druk op een pijltoets om
naar het gewenste veld te navigeren. Druk om een veld te selecteren of gegevens
in een veld in te vullen op de knop OK. Als u tekst in een veld invult, druk dan op de
knop OK als u klaar bent.
Bij de eerste keer opstarten van de W-1 verschijnt het scherm Eerste keer
opstarten.
Maak gebruik van de navigaeknoppen om de gewenste taal, jd, datum en
gewichtsvelden te kiezen. Druk zodra het veld is gemarkeerd op OK om de wijziging
toe te passen. Navigeer naar de knop Opslaan en druk op OK om de wijzigingen
op te slaan.
Om deze instellingen later te wijzigen, kunt u naar Instellingen rechts in het
Home-scherm gaan.
VERBINDING MET WIFI MAKEN
Verbinding met wifiop de W-1 maakt communicae met gegevensapparaten
mogelijk. Het maakt ook synchronisae van diergegevens met de Animal
Performance-app mogelijk en zorgt ervoor dat de W-1 de meest recente
soware-updates kan ontvangen.
1. Selecteer Instellingen > ApparaatInstellingen > Wi-Fi.
2. Zorg ervoor dat Wifiinschakelen is geselecteerd.
3. Selecteer Zoeken. De W-1 zoekt naar beschikbare netwerken.
4. Selecteer uw wifinetwerk en voer het wifiwachtwoord in.
Hint: Het is handig om jdens het typen het wachtwoord te Tonen. Druk op
OK om het wachtwoordveld te verlaten om naar de knop Tonen te gaan en
selecteer daarna OK. Ga naar het wachtwoordveld en selecteer OK om het
wachtwoord in te voeren
5. Selecteer Gereed en daarna Verbinden.

19
Gebruikershandleiding Gallagher W-1 Weegschaal
Nederlands
APPARATUUR OP DE W-1 AANSLUITEN
Aansluiten op draadloze weegbalken
1. Selecteer in de TW-1 op Instellingen > Apparatuuraansluingen >
Weegbalken > Draadloos.
2. De TW-1 zal op zoek gaan naar de weegbalken. Wanneer de weegbalken
eenmaal gelokaliseerd zijn, selecteert u ze door uw keuze aan te kken in de
lijst en vervolgens te kken op Verbinden.
Opmerking: Volgens de instruces voor de installae van draadloze
weegbalken moeten uw weegbalken ingeschakeld zijn en binnen bereik zijn
om in de zoeklijst te worden weergegeven.
3. Het kan tot 30 seconden duren om uw weegbalken met de TW-1 te koppelen.
Na afronding selecteer Gereed.
4. Druk op de knop Home.
5. Om een nieuwe sessie aan te maken selecteert u Nieuw. Het huidige gewicht
wordt weergegeven als 0,0 kg. Druk op de nul-toets als er geen 0,0 staat.
Druk enigszins op de balken om te controleren of de verbinding werkt.
Opmerking: Na 15 minuten inacviteit wordt de verbinding met de draadloze
weegbalken verbroken omdat de W-1 in de slaapstand gaat. Druk op de
aan/uit-knop en ga naar het weegscherm om opnieuw verbinding te maken.
Verbinding maken met een EID-reader
De EID-reader maakt verbinding met de W-1 via Bluetooth®.
1. Schakel de EID Reader in.
2. Schakel de W-1 in.
3. Selecteer de
W-1 op Instellingen > Apparatuuraansluingen > EID
Reader.
Belangrijk: U kunt ook verbinding maken met uw W-1 door een Blue-
tooth®-verbinding vanaf uw lezer te iniëren. Om deze aansluing te voltooien,
kan het wachtwoord “0000” vereist zijn.
Bekijk de Gebruikershandleiding van de EID-reader voor meer informae over het
koppelen van de reader.

20
Gebruikershandleiding Gallagher W-1 Weegschaal
Nederlands
Om de sessie naar wens
in te stellen: Selecteer de
knop Opes links onderin
uw scherm. Hier kunt u de
weegstand, selecteeropes
en sessienaam instellen.
“Sessie-opes” (p 21) voor
meer informae.
Gegevensapparaat
Apparaten van derden, zoals printers, kunnen worden gekoppeld om
gewichtsinformae te ontvangen. Een gegevensapparaat kan worden verbonden
via Bluetooth® of wifi.
1. Zet het gegevensapparaat aan.
2. Zet de TW-1 aan.
3. Selecteer op de W-1 Instellingen > Apparatuuraansluingen >
Gegevensapparaat.
EEN SESSIE STARTEN
Als u informae over een dier verzamelt, wordt deze in een sessie vastgelegd. Elk
evenement (zoals wegen) voegt een record aan de huidige sessie toe.
Opmerking: Wij bevelen aan om voor een acviteit op een nieuwe dag of voor een
nieuwe groep dieren een nieuwe sessie te openen. Een dier kan niet vaker dan één
keer in dezelfde sessie verschijnen.
Een nieuwe sessie starten:
1. Selecteer in het scherm Home Nieuw . en druk op OK. Het scherm
Nieuwe Sessie wordt getoond.
Belangrijk: Voorafgaand aan het wegen moet 0.0 worden weergegeven. Als
dat niet het geval is, drukt u op .
2. Laat het dier op het plaorm lopen.
3. Indien gewenst kunt u het visuele tagnummer van het dier opslaan of het
elektronische oormerk scannen.
4. Bij wegen in AUTO - Automasche gewichtsvergrendeling vergrendelt
de weegschaal het gewicht en houdt dit op het scherm totdat het dier het
plaorm verlaat.
Bij wegen in MAN - Handmage gewichtsvergrendeling moet u eerst op
Weeg drukken. Als het gewicht stabiel wordt, vergrendelt het.
5. Laat het dier van het plaorm stappen.
Other manuals for W-1
1
Table of contents
Languages:
Other Gallagher Scale manuals

Gallagher
Gallagher SmartScale 600 User manual

Gallagher
Gallagher TW-1 User manual

Gallagher
Gallagher W-1 User manual

Gallagher
Gallagher DS5000 User manual

Gallagher
Gallagher SmartScale 700 User manual

Gallagher
Gallagher W-0 User manual

Gallagher
Gallagher W210 User manual

Gallagher
Gallagher DAIRY SCALE XDS5000 User guide

Gallagher
Gallagher SmartScale 300 User manual

Gallagher
Gallagher TWR-1 User manual