Logix Series Quick Start Guide
150
Stainless Steel Control Valve
2
Progra mming Your Control
General Program Reference Guide
To Change a Value:
• Use or to select value to change.
• Then press until value blinks.
• The use or to scroll through value
options.
• Then press to enter value.
NOTE: A locked value ( ) cannot be changed until it is
unlocked.
To Star t Manual Regeneration:
• Press for regeneration today .
• Hold for 5 seconds for immediate regeneration.
During a Regeneration:
• Press or or to view current cy cle
time remaining.
• Press AND to advance cy cles.
• Hold AND for 5 seco nds to cancel
regeneration.
To Program Individual Cy cle T imes:
Note: Only required to override current settings.
• Hold AND for 5 seco nds.
• Then use or to scroll through cycles.
C1= Backwash
C2 = Regenerant Draw
C3 = Slow Rinse
C5 = Fast Rinse
C8 = Regenerant Refill
• Then press until value blinks.
• Then use or to scroll.
• Then press to enter value.
Setting the 7-Day Clock (742 and 742F only)
• Set the Days Override to "0".
• W ith arrow on “Regen Time/Day, press until
arrow flashes under desired day of week.
• Then use or until black bar is displayed
indicating regeneration that day.
• Press to advance to next day.
To Reset the Valve Type:
NOTE: All values are reset to factory defaults.
• Hold AND for 5 seco nds.
• When “HO” is displayed, hold for 5 seconds.
• Then press or to change valve type.
• Then press to enter displayed valve type.
SET
UP
DOWN
REGEN
LOCKED VALUE
Time& Day
RegenTime & Day
Salt
SU MO TU WE TH FR SA DAYS
LBS
PM
MIN
KG
x100
x2
P
H
C
Capacity
Hardness
Control:
Syst em Type:
Use Page:
762
Time/Day
Regeneration Time/Day
Salt Amount
Capacity
Hardness
4-Cycle
Conditioner
3
742
Time/Day
Regeneration Time/Day
Salt Amount
Capacity
4-Cycle
Conditioner
4
762F
Time/Day
Capacity
Backwash Time/Day
Backwash Length
3-Cycle
Filter
5
742F
Time/Day
Backwash Time/Day
Backwash Length
3-Cycle
Filter
6
Regeneration StartMetered Clock or Remote Signal Metered Clock or Remote Signal
Identify your control
by matching the
display text to the
guide
150 Quick Start
3
Grains/gal:3
to
200
SU MO TU WE TH FR SA DAYS
SU MO TU WE TH FR SA DAYS
SU MO TU WE TH FR SA DAYS
SU MO TU WE TH FR SA DAYS
SU MO TU WE TH FR SA DAYS
SU MO TU WE TH FR SA DAYS
SU MO TU WE TH FR SA DAYS
Lbs/ft3
SU MO TU WE TH FR SA DAYS
KG
Time/Day
Salt Amount
SU MO TU WE TH FR SA DAYS
Capacity
Hardness
Time/Day
Regeneration Time/Day
Salt Amount
SU MO TU WE TH FR SA DAYS
Capacity
Hardness
1. Valve Type
 Select 150 for 4-Cycle Single tank conditioner
or
 Select 2150 for 4-Cycle Twin-Alternating conditioner
2. Resin Volume
Select correct resin volume Cubic feet: 3.00
to
17.00
3. Time of Day (12 hr.)
Set to actual time of day
Note: Setting includes PM indicator.
4. Day of Week
Set to actual day of the week
5. Time of Regeneration
Set to desired time of regeneration
Note: Time of Regeneration is ignored for Twin-alternating.
6. Days Override
Leave at 0 to disable
or
Set to desired days override
7. Salt Dosage
Set to desired dosage
lbs per cubic feet of resin
8. Capacity
Estimated exchange capacity
calculated by Logix control
Use to OVERRIDE calculated
capacity
9. Hardness
Set to actual water hardness
Screen Buttons to Description Range
Press
0
to
99
Lbs/f
t3
: 3
to
18
Kilograins:1
to
9999
Programmming is complete
or
press
then
or
press
then
or
press
press
then
or
press
press
then
or
press
press
then
or
press
press
then
or
press
press
then
or
press
press
then
press
or
press
press
then
to override
Service Display
Toggles between Capacity Remaining
(gallons or m ) and Flow Rate (g/m
or L/m)
150 Demand 762 4-Cycle Conditioner
PM
Max. Days
Between Regen:
In Service LED is On
In Service
3
Grams/Liter: 30
to
2000
grams/Liter: 50
to
290
Kilograms:0.1
to
999.9
Liters:75
to
500
Time/Day
Salt Amount
Capacity
Hardness
Time/Day
Salt Amount
Capacity
Hardness
Time/Day
Salt Amount
Capacity
Hardness
Time/Day
Salt Amount
Capacity
Hardness
Time/Day
Salt Amount
Capacity
Hardness
Time/Day
Salt Amount
Capacity
Hardness
Time/Day
Salt Amount
Capacity
Hardness
Time/Day
Salt Amount
Capacity
Hardness
Regeneration Time/Day
Regeneration Time/Day
Regeneration Time/Day
Regeneration Time/Day
Regeneration Time/Day
Regeneration Time/Day
Regeneration Time/Day
Regeneration Time/Day
Regeneration Time/Day
4
SU MO TU WE TH FR SA DAYS
SU MO TU WE TH FR SA DAYS
SU MO TU WE TH FR SA DAYS
SU MO TU WE TH FR SA DAYS
SU MO TU WE TH FR SA DAYS
SU MO TU WE TH FR SA DAYS
SU MO TU WE TH FR SA DAYS
KG
SU MO TU WE TH FR SA DAYS
2. Resin Volume
Select correct resin volume Cubic feet: 3.00
to
17.00
3. Time of Day (12 hr.)
Set to actual time of day
Note: Setting includes PM indicator.
4. Day of Week
Set to actual day of the week
5. Time of Regeneration
Set to desired time of regeneration
6. Days Between Regeneration
Set to desired days between
regeneration
or
Set at 0 to program as a 7-day
timer
7. Salt Dosage
Set to desired dosage
8. Estimated Exchange Capacity (view only)
Based on resin volume and
salt setting
Screen Buttons to Description Range
Press
Days:0
to
99
Lbs/ft3:3
to
18
Programmming is complete
or
press
then
or
press
then
or
press
press
then
or
press
press
then
or
press
press
then
or
press
press
then
or
press
press
then
press
Service Display
Displays actual day of the week
and time of day
PM
PM
150 Time Clock 742 4-Cycle Conditioner
1. Valve Type
 Select 150 for 4-Cycle Single tank conditioner
or
 Select 2150 for 4-Cycle Twin-Alternating conditioner
Time/Day
Salt Amount
SU MO TU WE TH FR SA DAYS
Capacity
In Service LED is On
In Service
Grams/Liter: 50
to
290
Liters:75
to
500
Time/Day
Salt Amount
Capacity
Time/Day
Salt Amount
Capacity
Time/Day
Salt Amount
Capacity
Time/Day
Salt Amount
Capacity
Time/Day
Salt Amount
Capacity
Time/Day
Salt Amount
Capacity
Time/Day
Salt Amount
Capacity
Lbs/ft3
Time/Day
Salt Amount
Capacity
Regeneration Time/Day
Regeneration Time/Day
Regeneration Time/Day
Regeneration Time/Day
Regeneration Time/Day
Regeneration Time/Day
Regeneration Time/Day
Regeneration Time/Day
Regeneration Time/Day
5
SU MO TU WE TH FR SA DAYS
SU MO TU WE TH FR SA DAYS
SU MO TU WE TH FR SA DAYS
SU MO TU WE TH FR SA DAYS
SU MO TU WE TH FR SA DAYS
Time/Day
SU MO TU WE TH FR SA DAYS
Capacity
SU MO TU WE TH FR SA DAYS
SU MO TU WE TH FR SA DAYS
2. Program Type
Select "F"
3. Time of Day (12 hr.)
Set to actual time of day
Note: Setting includes PM indicator.
4. Day of Week
Set to actual day of the week
5. Time of Backwash
Set to desired time of backwash
Note: Time of Backwash is ignored for Twin-alternating.
6. Days Override
Leave at 0 to disable
or
Set to desired days override
7. Backwash Length (minutes)
Set to desired backwash length
8. Capacity (gallons)
Set to desired capacity in
Screen Buttons to Description Range
Press
0
to
99
Minutes:1
to
250
Gallons:1
x 100
to
9999
Programmming is complete
or
press
then
press
or
press
press
then
or
press
press
then
or
press
press
then
or
press
press
then
or
press
press
then
or
press
press
then
PM
Backwash Time/Day
Backwash Length
MIN
X100
150 Demand 762F - 3-Cycle Filter
1. Valve Type
 Select 153 for 3-Cycle Single tank filter
or
 Select 2153 for 3-Cycle Twin-Alternating filter
Max. Days
Between Regen:
m3:1
to
999.9
Time/Day
Capacity
Backwash Time/Day
Backwash Length
Time/Day
Capacity
Backwash Time/Day
Backwash Length
Time/Day
Capacity
Backwash Time/Day
Backwash Length
Time/Day
Capacity
Backwash Time/Day
Backwash Length
Time/Day
Capacity
Backwash Time/Day
Backwash Length
Time/Day
Capacity
Backwash Time/Day
Backwash Length
Time/Day
Capacity
Backwash Time/Day
Backwash Length
SU MO TU WE TH FR SA DAYS
Service Display
In Service
Time/Day
Capacity
Backwash Time/Day
Backwash Length
Toggles between Capacity Remaining
(gallons or m ) and Flow Rate (g/m
or L/m)
In Service LED is On
3
6
Time/Day
SU MO TU WE TH FR SA DAYS
SU MO TU WE TH FR SA DAYS
SU MO TU WE TH FR SA DAYS
SU MO TU WE TH FR SA DAYS
SU MO TU WE TH FR SA DAYS
SU MO TU WE TH FR SA DAYS
SU MO TU WE TH FR SA DAYS
SU MO TU WE TH FR SA DAYS
2. Program Type
Select "F"
3. Time of Day (12 hr.)
Set to actual time of day
Note: Setting includes PM indicator.
4. Day of Week
Set to actual day of the week
5. Time of Backwash (12 hr)
Set to desired time of backwash
6. Days Between Regeneration
Set to desired days between
regeneration
or
Set to 0 to program as a 7-day
timer
7. Backwash Length (minutes)
Set to desired backwash length
Screen Buttons to Description Range
Press
Days:0
to
99
Minutes:1
to
250
Programmming is complete
or
press
then
press
or
press
press
then
or
press
press
then
or
press
press
then
or
press
press
then
or
press
press
then
Service Display
Displays actual day of week and
time of day.
PM
Backwash Time/Day
Backwash Length
MIN
PM
150 Time Clock 742F - 3-Cycle Filter
1. Valve Type
 Select 153 for 3-Cycle Single tank filter
or
 Select 2153 for 3-Cycle Twin-Alternating filter
In Service LED is On
Time/Day
Backwash Time/Day
Backwash Length
Time/Day
Backwash Time/Day
Backwash Length
Time/Day
Backwash Time/Day
Backwash Length
Time/Day
Backwash Time/Day
Backwash Length
Time/Day
Backwash Time/Day
Backwash Length
Time/Day
Backwash Time/Day
Backwash Length
Time/Day
Backwash Time/Day
Backwash Length
© Copyright 2007 General Electric Company
Printed in U.S.A. P/N 3017534 Rev. B

This manual suits for next models

1

Other GE Control Unit manuals

GE NX-1710E - Single Door Control Module Installation and operation manual

GE

GE NX-1710E - Single Door Control Module Installation and operation manual

GE b30 User manual

GE

GE b30 User manual

GE ATS7200 User manual

GE

GE ATS7200 User manual

GE EntelliGuard TU User manual

GE

GE EntelliGuard TU User manual

GE CompactPCI VMIACC-7055 Series User manual

GE

GE CompactPCI VMIACC-7055 Series User manual

GE IC3645SR4T405CT1 User manual

GE

GE IC3645SR4T405CT1 User manual

GE Evolution Series E9000 User manual

GE

GE Evolution Series E9000 User manual

GE VersaMax IC200ALG630 User manual

GE

GE VersaMax IC200ALG630 User manual

GE Masoneilan 41005 Series User manual

GE

GE Masoneilan 41005 Series User manual

GE WH18X28174 Configuration guide

GE

GE WH18X28174 Configuration guide

GE IC3645SR4W746N5 User manual

GE

GE IC3645SR4W746N5 User manual

GE WIU-4 User manual

GE

GE WIU-4 User manual

GE 12000 Parts list manual

GE

GE 12000 Parts list manual

GE IC695CMM002CA-EJ User manual

GE

GE IC695CMM002CA-EJ User manual

GE MM200 User manual

GE

GE MM200 User manual

GE Dialog User manual

GE

GE Dialog User manual

GE VersaSafe VersaPoint IC220SDL840 User manual

GE

GE VersaSafe VersaPoint IC220SDL840 User manual

GE ARITECH ATS7300 User manual

GE

GE ARITECH ATS7300 User manual

GE IC693CBL300 User manual

GE

GE IC693CBL300 User manual

GE CR194 User manual

GE

GE CR194 User manual

GE Baker Hughes 2900-40 Series User manual

GE

GE Baker Hughes 2900-40 Series User manual

GE NetworX Series User manual

GE

GE NetworX Series User manual

GE 21861 User manual

GE

GE 21861 User manual

GE EX2100 User manual

GE

GE EX2100 User manual

Popular Control Unit manuals by other brands

WAGO 750-632 manual

WAGO

WAGO 750-632 manual

Harvia Griffin Infra CG170I manual

Harvia

Harvia Griffin Infra CG170I manual

Baker Hughes Consolidated 4900 Series instruction manual

Baker Hughes

Baker Hughes Consolidated 4900 Series instruction manual

TLV MC-COSR-3 instruction manual

TLV

TLV MC-COSR-3 instruction manual

Pentair Keystone Figure 952 NPS 2 Disassembly instructions

Pentair

Pentair Keystone Figure 952 NPS 2 Disassembly instructions

Siemens SITRANS F M MAGFLO series operating manual

Siemens

Siemens SITRANS F M MAGFLO series operating manual

COMAIR Delta 52YF manual

COMAIR

COMAIR Delta 52YF manual

Field Controls CK-43 instruction manual

Field Controls

Field Controls CK-43 instruction manual

Savant Pro Host Quick reference guide

Savant

Savant Pro Host Quick reference guide

Karel PG100-CU Technical reference and user's guide

Karel

Karel PG100-CU Technical reference and user's guide

Ebyte E78-900M22S1A user manual

Ebyte

Ebyte E78-900M22S1A user manual

Interlogix TruPortal TP-ADD-2D Series quick reference

Interlogix

Interlogix TruPortal TP-ADD-2D Series quick reference

Volth ARGO HYTOS SD2P2X-B4 operating instructions

Volth

Volth ARGO HYTOS SD2P2X-B4 operating instructions

NimbeLink Skywire NL-SW-LTE-SRC7611 Networking guide

NimbeLink

NimbeLink Skywire NL-SW-LTE-SRC7611 Networking guide

Forney HA-0619 instruction manual

Forney

Forney HA-0619 instruction manual

Analytik Jena multi N/C 2100 operating manual

Analytik Jena

Analytik Jena multi N/C 2100 operating manual

Lenze EPM-H310 operating instructions

Lenze

Lenze EPM-H310 operating instructions

Vertiv NetSure7100 Series Installation and user manual

Vertiv

Vertiv NetSure7100 Series Installation and user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.