Ettan IPGphor 3 Instrument User Manual11-0034-58 Edition AB v
Contents
1 Ettan IPGphor 3 Isoelectric Focusing System function and
description
1.1 Unpacking ............................................................................................................9
1.2 System components .......................................................................................9
1.3 Specifications ...................................................................................................17
1.4 Associated documentation ........................................................................18
2 Instrument set up
2.1 Placing the instrument .................................................................................19
2.2 Power connection ..........................................................................................19
2.3 Serial port connector for a computer connection ..........................20
3 Operating instructions
3.1 Power up .............................................................................................................21
3.1.1 Ettan IPGphor 3 control panel......................................................................21
3.2 Using the Ettan IPGphor Cup Loading Manifold ..............................23
3.2.1 Rehydrating Immobiline DryStrip in the Rehydration Tray.............23
3.2.2 Positioning the manifold on the Ettan IPGphor 3.................................23
3.2.3 Positioning the IPG strips in the manifold................................................23
3.2.4 Sample cups.........................................................................................................24
3.2.5 Electrode paper wicks......................................................................................24
3.2.6 Positioning the electrodes..............................................................................24
3.2.7 Loading samples into the sample cups...................................................24
3.3 Using fixed-length Ettan IPGphor 3 strip holders ............................25
3.3.1 Preparing the strip holder(s)..........................................................................25
3.3.2 Optional: Sample rehydration under voltage........................................27
3.3.3 Optional: Applying electrode pads prior to IEF......................................28
3.3.4 Optional: Applying sample after rehydration........................................28
3.3.5 Positioning the strip holders..........................................................................29
3.3.6 Closing the safety lid.........................................................................................30
3.4 Running a pre-programmed protocol from the PC ........................32
3.4.1 Ettan IPGphor 3 Control Software...............................................................32
3.4.2 Starting the Ettan IPGphor 3 Control Software.....................................33
3.5 Creating, editing, and running protocol programs from the
Ettan IPGphor 3 control panel ..................................................................37
3.5.1 Protocol parameters.........................................................................................37
3.5.2 Editing protocol parameters..........................................................................38
3.5.3 Starting isoelectric focusing from the Ettan IPGphor 3 control
panel........................................................................................................................44
3.5.4 Pausing or stopping a protocol....................................................................48
3.5.5 Printing a log of instrument conditions....................................................48