GE CareScape V100 User manual

GE Healthcare
CARESCAPE™V100 Vital Signs Monitor
Service Manual
CARESCAPE V100 Vital Signs Monitor
English
2037106-001 B (paper)
© 2007, 2008 General Electric Company.
All Rights Reserved.


GE Healthcare
CARESCAPE™V100 Vital Signs Monitor
Service Manual
CARESCAPE V100 Vital Signs Monitor
English
2037106-001 B (paper)
© 2007, 2008 General Electric Company.
All Rights Reserved.

T-2 CARESCAPE V100 Vital Signs Monitor 2037106-001 B
17 September 2008
NOTE: The information in this manual also applies to CARESCAPE V100 Vital Signs Monitor software version RAA. There
are no user-apparent differences among these software versions. Due to continuing product innovation, specifications
in this manual are subject to change without notice.
NOTE: For technical documentation purposes, the abbreviation GE is used for the legal entity name, GE Medical
Systems Information Technologies.
Listed below are GE Medical Systems Information Technologies trademarks. All other trademarks contained herein are
the property of their respective owners.
Ohmeda Oximetry and other trademarks (OxyTip+, PIr, TruSat, TruSignal, TruTrak+) are the property of GE Medical
Systems Information Technologies, a division of General Electric Corporation. All other product and company names are
the property of their respective owners.
Alaris Turbo Temp and IVAC are trademarks of Cardinal Health, Inc.
CRITIKON, DINAMAP, SuperSTAT, and DURA-CUF and SOFT-CUF Blood Pressure Cuffs are trademarks of GE Medical
Systems Information Technologies.
Masimo SET, LNOP, and LNCS are trademarks of Masimo Corporation. Possession or purchase of this device does not
convey any express or implied license to use the device with replacement parts which would, alone, or in combination
with this device, fall within the scope of one or more of the patents relating to the device.
Nellcor, OxiMax, C-LOCK and SatSeconds are trademarks of Nellcor Puritan Bennett.

2037106-001B CARESCAPE V100 Vital Signs Monitor i
Contents
1Introduction . . . . . . . . . . . . . . . . . . . . . . 1-1
Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Manual Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Ordering Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Responsibility of the Manufacturer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4
References to Persons, Places, and Institutions . . . . . . . . . . . . . . . . . . . . . .1-4
Warnings, Cautions, and Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5
Product Specific Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5
Equipment Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
Service Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
Equipment ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
Intended Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10
General Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10
Related Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10
Service Policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10
Service Contracts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10
Assistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10
Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11
Packing Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11
Insurance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11
Service No Charge Rental . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12
Repair Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12
Disposal of Product Waste . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12
Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12
Patient Applied Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13
Packaging Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13
Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13

ii CARESCAPE V100 Vital Signs Monitor 2037106-001B
2Equipment Overview . . . . . . . . . . . . . . 2-1
Equipment Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Product Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
Basic Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Buttons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-4
Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Product Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
Theory of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-8
Overall Principles of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
SpO2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-9
Cuff Blood Pressure (NIBP) and Pulse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-9
DINAMAP SuperSTAT Algorithm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10
Systolic Search . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11
DINAMAP Classic and Auscultatory Reference Algorithm . . . . . . . . . . . 2-12
Systolic Search . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13
Reference Used to Determine NIBP Accuracy . . . . . . . . . . . . . . . . . . . . . . 2-13
CARESCAPE V100 Monitors With Intra-Arterial Reference
(DINAMAP SuperSTAT and Classic Technology) . . . . . . . . . . . . . . . . 2-14
CARESCAPE V100 Monitors With Auscultatory Reference
(DINAMAP Auscultatory Reference Technology) . . . . . . . . . . . . . . . . 2-14
Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-14
Host Communication Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-14
Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-14
Main Board PWA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-15
User Interface (UI) Board PWA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-15
SpO2 PWA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-16
Printer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-16
Pneumatics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-16
Optical Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-16

2037106-001B CARESCAPE V100 Vital Signs Monitor iii
3Installation . . . . . . . . . . . . . . . . . . . . . . . 3-1
Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Right-Side Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-3
Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-3
Powering the Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4
Power Sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4
Battery Charging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4
BATTERY OK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-5
Battery Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-5
E13 Battery Low . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-6
Unpacking and Preparation for Installation . . . . . . . . . . . . . . . . . . . . . . . . 3-6
Configuring Your V100 Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7
Operating Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-7
Clinical Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-7
Configuration Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-7
Advanced Configuration Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11
Service Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12
Host Communications Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-15
DB15 Connector Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-15
Connection Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-15
4Maintenance . . . . . . . . . . . . . . . . . . . . . 4-1
Preventative Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-3
Integrity of Hoses and Cuffs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-3
Visual Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
Cleaning the Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-4
Cuffs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-5
Temperature Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-6
SpO2 Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-6
Long-Term Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
Battery Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-7
Replacing the Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-8

iv CARESCAPE V100 Vital Signs Monitor 2037106-001B
Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-9
Parameter Level Functional Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
NIBP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-9
Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-9
Ohmeda, Nellcor, and Masimo SpO2 Technologies . . . . . . . . . . . . . . . . . 4-10
Calibration Procedures and Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10
Annual Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10
Parameter Test Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11
Pneumatic Leakage Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12
Pressure Transducer Verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12
Pressure Transducer Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13
Overpressure Verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13
Button Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14
LED Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14
External DC Verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14
NIBP Determination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14
NIBP Overpressure Verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15
Temperature (Perform if equipped with Temp module) . . . . . . . . . 4-15
SpO2 (Perform only if equipped with SpO2 module) . . . . . . . . . . . . 4-16
Printer Output Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-16
Safety Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-17
SpO2 Circuit Leakage Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-17
Temp Circuit Leakage Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-17
Test Results Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-18
5Troubleshooting . . . . . . . . . . . . . . . . . . 5-1
Alarm Code Interpretation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3
System Failures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-3
Alarm Conditions and Error Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-3
Error Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-3
Procedure to View and Print Error Code History Log: . . . . . . . . . . . . .5-3
Error Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-5
6Parts List, Drawings, and
Replacement . . . . . . . . . . . . . . . . . . . . . 6-1
Ordering Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3

2037106-001B CARESCAPE V100 Vital Signs Monitor v
Service Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3
Compatible Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-3
Field-Replaceable Units (FRUs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-8
FRU List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-8
FRU Photos . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-11
FRU Main Reference Guide Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-21
Assembly/Disassembly of FRUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-29
Monitor Disassembly Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-29
Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-29
Rear Case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-30
Printer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-31
SpO2 Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-32
Front Bezel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-32
Main Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-33
Display Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-33
ATechnical Specifications and Default
Settings . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3
Printer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-4
NIBP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-4
Ohmeda SpO2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-5
Nellcor SpO2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-7
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-7
Masimo SpO2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-9
Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-11
Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-12
Default Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-12
Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-12
NIBP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-12
Ohmeda SpO2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-13
Nellcor SpO2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-13
Masimo SpO2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-13
Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-13

vi CARESCAPE V100 Vital Signs Monitor 2037106-001B
BAppropriate Use of NIBP Simulators . B-1
Appropriate Use of NIBP Simulators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-3
NIBP Accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-3
Clinical vs. Simulator Readings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-3
What Do Simulator Manufacturers Say? . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-4
Why Use Simulators? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-5
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-5
CElectromagnetic Compatibility
(EMC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1
Electromagnetic Compatibility (EMC): CARESCAPE V100 Monitor . . . . . C-3
Guidance and Manufacturer’s Declaration – Electromagnetic
Emissions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-3
Guidance and Manufacturer’s Declaration – Electromagnetic
Immunity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-4
Recommended Separation Distances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-6
Compliant Cables and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-7

1Introduction

1-2 CARESCAPE V100 Vital Signs Monitor 2037106-001 B
For your notes

2037106-001 B CARESCAPE V100 Vital Signs Monitor 1-3
Introduction: Revision History
Revision History
Each page of this manual has a revision letter located at the bottom of the page.
This letter identifies the revision level of the entire manual. This may be important
if you have different manuals and you do not know which is the most current.
For the initial release, all pages have the revision letter A. For the second update,
all pages receive the revision letter B. The latest letter of the alphabet added to
the table below corresponds to the most current revision.
Manual Purpose
This manual supplies technical information for service representatives and
technical personnel so they can maintain the equipment to the assembly level.
Use it as a guide for maintenance and electrical repairs considered field
repairable. Where necessary the manual identifies additional sources of relevant
information and technical assistance. See the operator's manual for the
instructions necessary to operate the equipment safely in accordance with its
function and intended use.
Ordering Manuals
A paper copy of this manual will be provided upon request. Contact your local GE
representative and request the part number on the first page of the manual.
Safety Information
The information presented in this section is important for the safety of both the
patient and operator. This chapter describes how the terms Danger, Warning,
Caution, Important, and Note are used throughout the manual. In addition,
standard equipment symbols are defined.
Revision Comment
ARelease of new manual
BUpdated CE marking information.

1-4 CARESCAPE V100 Vital Signs Monitor 2037106-001 B
Introduction: Safety Information
Responsibility of the Manufacturer
GE is responsible for the effects on safety, reliability, and performance only if:
assembly operations, extensions, readjustments, modifications, or repairs
are carried out by persons authorized by GE;
the electrical installation of the relevant room complies with the
requirements of appropriate regulations; and
the monitor is used in accordance with the instructions of use.
General
This device is intended for use under the direct supervision of a licensed health
care practitioner.
This device is not intended for home use. Federal law restricts this device to be
sold by or on the order of a physician.
Contact GE for information before connecting any devices to the equipment that
are not recommended in this manual.
Parts and accessories used must meet the requirements of the applicable IEC/
EN 60601 series safety standards, and/or the system configuration must meet
the requirements of the IEC 60601-1-1 medical electrical systems standard.
Periodically, and whenever the integrity of the device is in doubt, test all
functions.
The use of ACCESSORY equipment not complying with the equivalent safety
requirements of this equipment may lead to a reduced level of safety of the
resulting system. Consideration relating to the choice shall include:
use of the accessory in the PATIENT VICINITY; and
evidence that the safety certification of the ACCESSORY has been performed
in accordance to the appropriate IEC 60601-1 and/or IEC 60601-1-1
harmonized national standard.
If the installation of the equipment, in the USA, will use 240V rather than 120V,
the source must be a center-tapped, 240V, single-phase circuit.
References to Persons, Places, and Institutions
References to persons, places, and institutions used within this manual are solely
intended to facilitate user comprehension of the V100 Monitor’s use and
functions. Extreme care has been taken to use fictitious names and related
information in the examples and illustrations provided herein. Any similarity of
this data to persons either living or dead and to either current or previously
existing medical institutions should be regarded as coincidental.

2037106-001 B CARESCAPE V100 Vital Signs Monitor 1-5
Introduction: Safety Information
Warnings, Cautions, and Notes
The terms danger, warning, and caution are used throughout this manual to
point out hazards and to designate a degree or level or seriousness. Familiarize
yourself with their definitions and significance. Hazard is defined as a source of
potential injury to a person.
WARNING indicates a potential hazard or unsafe practice which, if not avoided,
could result in death or serious injury.
CAUTION indicates a potential hazard or unsafe practice which, if not avoided,
could result in minor personal injury or product/property damage.
NOTE provides application tips or other useful information to assure that you get
the most from your equipment.
Product Specific Hazards
WARNINGS
Do not use the CARESCAPE V100 Vital Signs Monitor in the
presence of magnetic resonance imaging (MRI) devices. There
have been reports of sensors causing patient burns when
operating in an MRI environment.
Do not use the Monitor in the presence of flammable anesthetics.
The use of approved accessories will provide protection from
burns during HF surgery. To help prevent unintended current
return paths with the use of high frequency (HF) surgical
equipment, ensure that the HF surgical neutral electrode is
properly connected.
To avoid personal injury, do not perform any servicing unless
qualified to do so.
These Monitors should not be used on patients who are
connected to cardiopulmonary bypass machines.
If powering the Monitor from an external power adapter or
converter, use only GE Medical Systems Information
Technologies-approved power adapters and converters.
The Monitor does not include any user-replaceable fuses. Refer
servicing to qualified service personnel.
To reduce the risk of electric shock, do not remove the cover or
the back. Refer servicing to a qualified service person.
If the accuracy of any determination reading is questionable,
first check the patient’s vital signs by alternate means and
then check the V100 Monitor for proper functioning.
Use of portable phones or other radio frequency (RF) emitting
equipment near the system may cause unexpected or adverse
operation.

1-6 CARESCAPE V100 Vital Signs Monitor 2037106-001 B
Introduction: Safety Information
WARNINGS
The equipment or system should not be used adjacent to, or
stacked with, other equipment. If adjacent or stacked use is
necessary, the equipment or system should be tested to verify
normal operation in the configuration in which it is being used.
The use of accessories, transducers and cables other than
those specified may result in increased emissions or decreased
immunity performance of the equipment or system.
CAUTIONS
Do not use replacement batteries other than the type supplied
with the Monitor. Replacement batteries are available from GE
Medical Systems - Accessories and Supplies.
The V100 Monitor is designed to conform to Electromagnetic
Compatibility (EMC) standard IEC 60601-1-2 and will operate
accurately in conjunction with other medical equipment which
also meets this requirement. To avoid interference problems
affecting the Monitor, do not use the Monitor in the presence of
equipment which does not conform to these specifications.
Place the V100 Monitor on a rigid, secure surface. Monitor must
only be used with mounting hardware, poles, and stands
recommended by GE Medical Systems Information
Technologies.
The weight of the accessory basket contents should not exceed
5 lb (2.7kg).
Arrange the external AC/DC power converter, air hoses, and all
cables carefully so they do not constitute a hazard.
Verify calibration of NIBP parameter (temperature and pulse
oximeter do not require calibration). Ensure that the display is
functioning properly before operating the V100 Monitor.
Do not immerse the Monitor in water. If the Monitor is splashed
with water or becomes wet, wipe it immediately with a dry cloth.
Do not gas sterilize or autoclave.
Caution should be taken to not set ALARM LIMITS to extreme
values, as this can render the ALARM SYSTEM useless.
The V100 Monitor, when used with GE Medical Systems
Information Technologies-approved applied parts and
accessories, is protected against defibrillator damage.
NOTE: The electromagnetic compatibility profile of the V100 Monitor may
change if accessories other than those specified for use with the V100
Monitor are used.

2037106-001 B CARESCAPE V100 Vital Signs Monitor 1-7
Introduction: Equipment Symbols
Equipment Symbols
The following symbols are associated with the V100 Vital Signs Monitor.
NOTE: The model of the monitor determines which symbols appear on it.
Attention, consult accompanying documents
Silence
Alarms
+ / - Increase / decrease adjustable settings
Menu
Inflate/Stop
Cycle
History
Print
On/Off
External communications port connector
Battery Power
Charging
External DC power input
Class II equipment according to IEC 60536
Defibrillator-proof type BF equipment

1-8 CARESCAPE V100 Vital Signs Monitor 2037106-001 B
Introduction: Equipment Symbols
Manufacturer: This symbol is accompanied by the name and the
address of the manufacturer.
Manufacturing Date: This symbol is accompanied by the date of the
manufacturing.
European authorized representative.
Packaging label depicting the transportation and storage
atmospheric pressure range of 500 to 1060 hPa.
WASTE OF ELECTRICAL AND ELECTRONIC EQUIPMENT
(WEEE): This symbol indicates that the waste of
electrical and electronic equipment must not be
disposed as unsorted municipal waste and must be
collected separately. Please contact an authorized
representative of the manufacturer for information
concerning the decommissioning of your equipment.
The CARESCAPE V100 Vital Signs Monitor is protected
against vertically falling drops of water and conforms
with the IEC 529 standard at level of IPX1. Vertically
falling drops shall have no harmful effects to the Monitor.
IPX1

2037106-001 B CARESCAPE V100 Vital Signs Monitor 1-9
Introduction: Service Requirements
Service Requirements
Follow the service requirements listed below.
Refer equipment servicing to GE Medical Systems Information Technologies
authorized service personnel only.
Any unauthorized attempt to repair equipment under warranty voids that
warranty.
It is the user’s responsibility to report the need for service to GE Medical
Systems Information Technologies or to one of GE’s authorized agents.
Failure on the part of the responsible individual, hospital or institution using
this equipment to implement a satisfactory maintenance schedule may
cause undue equipment failure and possible health hazards.
Regular maintenance, irrespective of usage, is essential to ensure that the
equipment will always be functional when required.
Equipment ID
The following graphic illustrates the components of the monitor’s serial number.
Intended Audience
This manual is intended for service representatives and technical personnel who
maintain, troubleshoot, or repair this equipment.
GEMS IT Global Serial Number Format
13- Digit
# # # # # # # # # # # # #
3-character product code
Year
Fiscal week
Sequential serial number (up to 9999)
Manufacturing site
Misc. : Prototype, refurbish, etc.

1-10 CARESCAPE V100 Vital Signs Monitor 2037106-001 B
Introduction: Service Policy
Intended Use
General Use
The V100 Monitor is intended to monitor one patient at a time in a clinical
setting.
Federal law (U.S.A.) restricts this device to sale by or on the order of a
physician.
To ensure patient safety, use only parts and accessories manufactured or
recommended by GE Medical Systems Information Technologies. Parts and
accessories used shall meet the requirements of EN60601.1.1.
Disposable devices are intended for single use only. They should not be
reused.
Periodically, and whenever the integrity of the monitor is in doubt, test all
functions.
Related Manuals
Service Policy
The warranty for this product is enclosed with the product in the shipper carton.
All repairs on products under warranty must be performed or approved by
Product Service personnel. Unauthorized repairs will void the warranty. Only
qualified electronics service personnel should repair products not covered by
warranty.
Service Contracts
Extended warranties can be purchased on most products. Contact your Sales
Representative for details and pricing.
Assistance
If the product fails to function properly, or if assistance, service or spare parts
are required, contact Customer Support. Before contacting Customer Support, it
is helpful to attempt to duplicate the problem and to check all accessories to
ensure that they are not the cause of the problem. If you are unable to resolve
the problem after checking these items, contact GE Medical Systems Information
Technologies. Prior to calling, please be prepared to provide:
product name, model number, and serial number
a complete description of the problem
Manual Title
2036991-001 CARESCAPE V100 Vital Signs Monitor Operator’s Manual
Other manuals for CareScape V100
1
Table of contents
Other GE Monitor manuals

GE
GE IC755CS06RD Series User manual

GE
GE PACSystems ICRXIDIXNE19LCTA User manual

GE
GE 1926A-1AN User manual

GE
GE TMO2D User manual

GE
GE Kelman Minitrans User manual

GE
GE CARESCAPE User manual

GE
GE Dinamap PRO Series User manual

GE
GE Responder 2000 User manual

GE
GE Bently Nevada 3300/03 User manual

GE
GE HandHeld Display (HHD) User manual

GE
GE Bently Nevada 3300/25 User manual

GE
GE Corometrics 250cx Series User manual

GE
GE UVis-920 User manual

GE
GE B40 User manual

GE
GE Bently Nevada 1900/27 User manual

GE
GE Dash 3000 User manual

GE
GE Dash 3000 User manual

GE
GE QuickPanel+ IC755CxS06RDx User manual

GE
GE HDTV Monitor User manual

GE
GE Aritech ATS1100 User manual