8.10 Smart Thermo heating
To increase the user's comfort, the surface of the treatment bed can be heated. The heating
control panel (see ill. 15 on page 11) enables the heating power to be set at 10 levels. To
quickly warm up the cold surface, the heating power is at maximum capacity for the duration of
the pre-heating time after starting. The heating parameters can be programmed and stored in
the memory according to your own preferences. Check the actual temperature before using the
bed and disconnect the power supply to the bed if you will not be using it for some time (e.g.
during the night).
8.10.1 Description of the control panel
The bed heating is controlled using the four "on", "off" and "+", "-" keys (see ill.15 on page 11).
The heating capacity setting is shown by the 10-part LED bar: Low capacity/low temperature:
green LEDs 1-4, medium capacity: yellow LEDs 5-7 and high capacity: red LEDs 8-10.
Do not use the Smart Thermo option in the following situations: on clients who have a
pacemaker, who are pregnant, who suffer from thrombosis or from pains whose cause
has not been identified. Only use the option on healthy people.
Never exceed the factory settings (pre-heating time: approx. 6 minutes, treatment power
level approx. 30%, 3 LEDs) when creating your own settings!
If the treatment is ended prematurely, the "Off" key on the control panel must be pressed
to switch off the Smart Thermo function and avoid heat accumulating.
We recommend removing the mains plug during long intervals between uses (e.g. during
the night).
Caution - risk of fire:
The bed must not be covered by objects such as blankets, towels, clothes etc. while the
heating is on, otherwise heat may accumulate and damage the bed.
8.10.2 Heating instructions
Press the "on" key (see ill.15 on page 11) to switch on the heating.
The programmed setting (see Programming) starts. The first step is heating automatically at the
highest power for the duration of the pre-heating time (factory setting = 6 min.).
When the pre-heating time has ended, the control system switches down to the treatment
setting (power = 30%) until the end of the operating time (factory setting = 60 min.). You can
press the "+" and "-" keys to end the pre-heating time and set the temperature in 10 levels.
Press the "Off" key to switch off the heating.
8.10.3 Initial settings
The bed is delivered with the following initial settings:
Total heating duration: 60 minutes (LED number 6)
Pre-heating time: 6 minutes (LEDs 1+2)
Continuous power: 30% (LEDs 1+2+3)
8.10.4 Programming
The values for the total operating time, the pre-heating time and the heating power can be
programmed.
You can access the programming mode by means of the following combination of keys:
Press and hold the "Off" key
Press and release the "On" key
When you then release the "Off" key you access the programming step: