manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Green Brook
  6. •
  7. Timer
  8. •
  9. Green Brook T105A Manual

Green Brook T105A Manual

Please read the instructions fully before
attempting installation.
IMPORTANT
This unit should be installed to current
IET wiring regulations if in doubt
consult a ualified electrician.
• Timer must not be mounted on a
flammable surface.
• Ensure that the timer does not come into
contact with any combustible materials
such as towels or bedding.
• Ensure at least a 300mm air space is
allowed around the timer.
• Prepare cable ends for connection to
terminals.
• Remove the 2 screws holding the
timeswitch cover to the backplate.
Remove cover leaving the timeswitch
hanging loose by its connection wires
to the backplate. DO NOT INTERFERE
WITH THESE FI ED CONNECTIONS.
Installation / Operating
Instructions for 7 Day
Electronic Socket Box Timer
- T105A
INSTALLATION
WIRING
2. Press Y to enter function setup. (Note:
if another button is not pressed within 10
seconds the display will revert to the
normal screen).
3. Use the + or - button to scroll to the clock
icon (flashing) and press Y to enter the
current time setting mode (hours
flashing).
4. If you keep the + or - buttons pressed for
more than 3 seconds, the display will
enter fast scroll mode.
5. Use the + or - button to adjust the hours
and press Y to confirm, minutes will flash.
6. Use the + or - button to adjust the
minutes and press Y to confirm, day will
flash.
7. Use the + or - button to adjust the day
and press N to exit.
1. When the timer is powered up set
current time & day. If no display is
showing leave on charge for 30 mins &
display should then show, If not gently
press the reset button.
1. There are 24 N/ FF programmes
available.
2. Press the Y button twice to enter the
programming setting mode.(Note: if
another button is not pressed within 10
seconds the display will revert to the
normal screen).
3. Default is programme 01 N, this can be
changed if required by pressing + or -
button to scroll through the 24 N/ FF
programmes as required, pressing the Y
will confirm the programme.
4. Press the Y button to confirm programme
01 N, hours will flash.
5. Use the + or - button to adjust the hours
and press Y to confirm, minutes will flash.
6. Use the + or - button to adjust the
minutes and press Y to confirm, days will
flash.
7. Apart from individual days of the week,
the following day combinations of
multiple day blocks can be selected by
pressing the + or - buttons.
• Monday to Sunday
• Monday to Friday
• Saturday to Sunday
• Monday to Saturday
• Monday + Wednesday + Friday
• Tuesday + Thursday + Saturday
• Monday + Tuesday + Wednesday
• Thursday + Friday + Saturday
8. Select day or day block as required and
press the Y button to confirm.
9. Press the + button, this will select the
programme 01 FF, press Y to confirm.
10.Follow 4 to 7 above to set the 01 FF
programme (day or day block must be
the same as programme N).
11.If no more programmes are required,
press the N button to exit.
12.If more programmes are required follow
3 above.
13.To cancel a programme once set, press
and hold the N button for more than 3
seconds when the desired programme
number is flashing i.e. to cancel
programme 01 N, press the Y button
twice and hold the N button down for
more than 3 seconds to delete. Pressing
the + button again will select 01 FF.
14.Repeat 13 to delete 01 FF. This
procedure can be repeated to delete
any of the 24 programmes.
CURRENT TIME AND
DAY SETTING
PROGRAMMING THE
SWITCHING TIMES
16AMP(2)
• Connect all earth wires to earthing point
in wall box.
• ffer up the backplate to the wall box
and connect the wiring as shown in
diagram below.
• When the wiring is complete screw the
backplate to the fitted wall box using
3.5mm screws.
• Push the timeswitch back in to its seating
on the backplate, taking care that all the
wires are tucked in. Fit the cover and
tighten the two screws.
IMPORTANT:
Ensure all Terminal screws are fully tightened.
T105A-C In July 21.qxp_Layout 1 24/11/2021 15:04 Page 1
MANUAL OVERRIDE
SUMMER TIME SETTING
TECHNICAL INFORMATION
RESET
TIMER COUNTDOWN
FUNCTION
READING YOUR
PROGRAMMED TIMES
1. Timer has a 100 hour countdown feature
i.e. the timer can be set to any period
from 1 minute to 100 hours and will
countdown in the N state and turn FF
at the end of the countdown period.
2. Press the Y button then use the + or -
button to select the “down” icon on the
right hand side of the display, press Y
again to enter the countdown mode.
3. Use the + or - button to adjust the hours
and press Y to confirm. minutes will flash.
4. Use the + or - button to adjust the
minutes and press Y to confirm and
complete the countdown time setting.
5. Press the N button to start the
countdown.
6. utput switched to N during the
countdown period.
7. Press the N button to pause the
countdown (output switched to FF)
8. To resume countdown simply press the N
button again.
9. Press and hold the N button for more
than 3 seconds to exit the countdown
function.
CE INFORMATION
ACTI N TYPE: IB
P LLUTI N SITUATI N: N RMAL
CLASS 2 INSULATI N:
:MICR -DISC NNECTI N LIVE
P LE NLY
1. When in normal clock mode, pressing
the N button will scroll through the
following switching options.
• ALWAYS N - timer is permanently N.
• PR G - timer is in programme N
mode, will switch off at the next
programme FF time.
• ALWAYS FF - timer is permanently FF.
• PR G - timer is in programme FF
mode, will switch on at the next
programme N time.
1. Press the Y button, then use the + or -
buttons to scroll through to “summer”
(flashing).
2. Press the Y button again to access the
summer time setting.
3. Press the + or - button to change
between summer on or off.
4. Press Y to confirm summer setting, time
will advance 1 hour.
5. A “SUMMER” icon will appear in the
display.
6. Use the same procedure to remove the
“SUMMER” icon when reverting to GMT
in the winter.
6. Timer will now operate in the random
mode.
7. To cancel random feature use the
procedure above to remove the
“RAND M” icon from the display.
Pressing the reset button R with a pencil or
similar will reset all programmed times and
set time of day to zero.
1. Press Y button twice to enter programme
mode.
2. Press the + or - buttons to scroll through
the 24 N/ FF programmes to check
settings.
3. Press the N button to exit and revert to
clock mode.
Switching Capacity: 230V AC,16A resistive,
2A Inductive
Ambient Temperature: -10°C to + 55°C
Battery Back Up: 150 hours
Memory Location: 24
Shortest Switching Time: 1 minute
Wattage: 3000W
Conforms To: BS EN 60730-1,
BS EN 60730-2-7
RANDOM SETTING
The random setting allows the timer to
switch N and FF with a random delay of
between 2 and 32 minutes. This function will
only
operate if one or more programmes have
been programmed into the timer.
1. Press the Y button, then use the + or -
buttons to scroll through to “RAND M”
(flashing).
2. Press the Y button again to access the
random setting.
3. Pressing the + or - buttons will toggle the
random icon on and off.
4. Press the Y button to confirm random
function.
5. A “RAND M” function icon will appear
in the display.
Issue no: 706351
WEST ROAD . HARLOW
ESSE . CM20 2BG . UK
info@greenbrook.co.uk
www.greenbrook.co.uk
GUARANTEE
Your GreenBrook 7 Day Electronic Timer
is guaranteed for 1 year from
the date of purchase.
This is in addition to your statutory rights.
PLEASE KEEP THESE INSTRUCTIONS
SAFE FOR FUTURE REFERENCE
IMPORTANT:
1. When you have completed the
programme settings ensure you set the
correct operating mode as shown in
manual override.
2. Do not leave uncharged for more than 6
months.
NOTE:
Product & Packaging Disposal
When disposing of this item and its packaging
please follow local regulations and use an
appropriate waste disposal centre.
See GreenBrook website for further details.
T105A-C In July 21.qxp_Layout 1 24/11/2021 15:04 Page 2

Other Green Brook Timer manuals

Green Brook T105-C Operating instructions

Green Brook

Green Brook T105-C Operating instructions

Green Brook T80-C User manual

Green Brook

Green Brook T80-C User manual

Green Brook T40S-C Manual

Green Brook

Green Brook T40S-C Manual

Green Brook KingShield T102-C User manual

Green Brook

Green Brook KingShield T102-C User manual

Green Brook T612-C User manual

Green Brook

Green Brook T612-C User manual

Green Brook KingShield T106A-C Manual

Green Brook

Green Brook KingShield T106A-C Manual

Green Brook TLS Manual

Green Brook

Green Brook TLS Manual

Green Brook T105-C Operating instructions

Green Brook

Green Brook T105-C Operating instructions

Green Brook T105A-C Installation and user guide

Green Brook

Green Brook T105A-C Installation and user guide

Green Brook T109 Manual

Green Brook

Green Brook T109 Manual

Green Brook T106A-C Manual

Green Brook

Green Brook T106A-C Manual

Green Brook T17B Manual

Green Brook

Green Brook T17B Manual

Green Brook T40S Manual

Green Brook

Green Brook T40S Manual

Green Brook T108A-C Manual

Green Brook

Green Brook T108A-C Manual

Green Brook T108A Manual

Green Brook

Green Brook T108A Manual

Green Brook T612-C Installation manual

Green Brook

Green Brook T612-C Installation manual

Green Brook T40S-C User manual

Green Brook

Green Brook T40S-C User manual

Green Brook T612-C Manual

Green Brook

Green Brook T612-C Manual

Popular Timer manuals by other brands

Swegon CACZ-1-05 Instruction

Swegon

Swegon CACZ-1-05 Instruction

RainPoint ITV101P user manual

RainPoint

RainPoint ITV101P user manual

Tork DGS180 manual

Tork

Tork DGS180 manual

VDH ALFA 804-ADS user manual

VDH

VDH ALFA 804-ADS user manual

Sygonix 2589190 operating instructions

Sygonix

Sygonix 2589190 operating instructions

Valex 1959904 Instruction manual and safety instructions

Valex

Valex 1959904 Instruction manual and safety instructions

LEGRAND Mallia 2810 91 quick start guide

LEGRAND

LEGRAND Mallia 2810 91 quick start guide

Emos One Touch Digital Tap Timer Pro manual

Emos

Emos One Touch Digital Tap Timer Pro manual

West Bend 40005X instruction manual

West Bend

West Bend 40005X instruction manual

Hanhart PRISMA 200 Guarantee Slip Instructions tor Use

Hanhart

Hanhart PRISMA 200 Guarantee Slip Instructions tor Use

VWR 61161-340 instruction manual

VWR

VWR 61161-340 instruction manual

Lumina DUO quick start guide

Lumina

Lumina DUO quick start guide

Click CLKTS02 operating instructions

Click

Click CLKTS02 operating instructions

Safety Technology International LT-1 quick start guide

Safety Technology International

Safety Technology International LT-1 quick start guide

Intermatic CT2000 Series quick start guide

Intermatic

Intermatic CT2000 Series quick start guide

Hozelock 2214 quick start guide

Hozelock

Hozelock 2214 quick start guide

Europa components ET167DYD operating instructions

Europa components

Europa components ET167DYD operating instructions

DS Produkte 08538 instructions

DS Produkte

DS Produkte 08538 instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.