A.FU E CARRIER Pull out to replace
fuse (a special 2A B 646 20mm x
5mm, this is not an ordinary fuse)
B.LCD DI PLAY
C. to G BUTTON TO ET DAY, TIME
AND PROGRAMME AND RANDOM
H.PU H ON/OFF WITCH ALLOW
UNIT TO OPERATE A ORDINARY
LIGHT WITCH ACTIVATE EVEN
WHEN LID I HUT.
L.OVERRIDE WITCH
MAN = MANUAL MODE
AUTO = AUTOMATIC PROGRAMME
MODE
J. RE ET BUTTON
K.RED NEON FUNCTION
IIFF IINN DDOOUUBBTT,, IINNSSTTAALLLLAATTIIOONN
SSHHOOUULLDD BBEE MMAADDEE BBYY AA QQUUAALLIIFFIIEEDD
EELLEECCTTRRIICCIIAANN IINN AACCCCOORRDDAANNCCEE WWIITTHH
CCUURRRREENNTT WWIIRRIINNGG RREEGGUULLAATTIIOONNSS
Before attempting any installation work
turn off the electrical supply at the mains
switch, fuse box or consumer unit and
for additional safety remove the fuse.
GreenBrook security wall light switches
cannot be used with other electronic
products.
1.After installation, the internal back up
battery will need to be fully charged to
enable correct operation.
2.After the main supply is switched back
on, wait 5minutes and operate the
reset button and allow the internal
battery to charge for 45-60 minutes.
After this period follow the operating
instructions as normal.
3.DO NOT use in two-way systems with
dimmers or any other switch
containing electronic circuitry.
(common) terminal. Incorrect wiring
will often result in a blown fuse.
hould the switch remain in-operative
after correcting the error, replace the
fuse with the spare provided.
4.If the light operates correctly from one
switch in a two way circuit then the
wiring is incorrect. Re-check to find
error. Check that the wire connected to
the L2terminal of the two way switch
has been removed and reconnected to
the C (common) terminal.
5.If the digital display goes blank when
the other switch in a two way circuit
is operated, please refer to no. 4
above.
IF A PROBLEM ARI E OME TIME
AFTER IN TALLATION
If loss of time and programmes set
occurs after the replacement of either a
blown fuse, blown bulb or power failure -
Press the RE ET button and reset the
correct time and day and re-programme
the required on and off times.
Every effort has been made to ensure
that the guidance information on this
sheet will enable the installation of the
security light switch to be carried out
safely and correctly.
AALLWWAAYYSS RREEPPLLAACCEE WWIITTHH AA SSPPEECCIIAALL
22AAMMPP BBSS664466 FFUUSSEE.. ((TTHHIISS IISS NNOOTT AANN
OORRDDIINNAARRYY 22AAMMPP FFUUSSEE))
PPLLEEAAEE KKEEEEPP TTHHEEEE
IINNTTRRUUCCTTIIOONN AAFFEE FFOORR FFUUTTUURREE
RREEFFEERREENNCCEE
4. uitable for tungsten filament bulbs
40W to 400W maximum and most low
energy (CFL) 11W and above. Not
suitable for low voltage lighting.
5.Not suitable in 3-way circuits.
NNOOTTEE
If using a metal backbox this should be
earthed.
YELLOW & GREEN EARTH MU T REMAIN
CONNECTED TO METAL BACK BOX
Before installing your ecurity Wall Light
witch in a two way circuit, it is first
necessary to determine which method of
wiring has been used in your home.
The primary reason for doing this is to
make sure that the switch is wired in
such a way that has a permanent live
feed at all times in order to power the
electronic timer.
1.TURN OFF THE MAIN UPPLY
2.Loosen the two switch plates from
the wall.
3.Do NOT disconnect any wires at this
stage.
4. tudy the existing wiring arrangement;
compare to the ‘before’ illustrations.
-If you find 3wires at each switch
(excluding the earth wire) see Diagram
3.-If you find 5wires at one switch and
5wires at the other (excluding the
earth wire) see Diagram 5.
After establishing the appropriate
wiring method, install the security light
switch as per the corresponding ‘after’
illustration.
ELECTRONIC WALL
SWITCH TIMER
INSTALLATION/OPERATING
INSTRUCTIONS
WIRING INSTRUCTIONS
WIRING INSTALLATION IN ONE
WAY SWITCHED CIRCUIT
WIRING INSTALLATION IN TWO
WAY SWITCHED CIRCUIT
Diagram 1- Before
Issue no: 701559
WEST ROAD . HARLOW
ESSE . CM20 2BG . UK
WWW.GREENBROOK.CO.UK
Diagram 2 - After
The position of the override switch H
does not affect the operation.With cover
plate up, the red neon K is still visible,
enabling you to check at a glance
whether the light switch is in AUTO
(programme mode), in which case the
Neon K will come ON if programme is
on and OFF if programme is off, or in
MANUAL mode when it will flash.To
access the controls mode when it will be
off. To access the controls again, grip the
cover plate with forefinger and thumb
either side and ease cover forward.
In the event of a light bulb “blowing” the
light switch will fail to operate. Always
disconnect power before replacing the
bulb by pulling the fuse carrier ’A’ until
the fuse is fully visible. It may be
necessary to replace the fuse if the
switch does not operate when the carrier
is pushed back into position following
bulb replacement. There is a slot in the
base of the carrier which allows the old
fuse to be pushed upwards and removed.
In order to ensure that the set
programmes do not overlap, it is
advisable to plan beforehand, using the
table below.
e.g. First programme will be set to come
on at 8.10pm until 11.06pm everyday.
1.If the digital display remains blank,
press the RE ET button. Also, check
that the light bulb has not blown.
2.If the light switch will not switch on
or off in a one way circuit, check that
the screws which fix the security light
switch to the wall box have not been
over tightened.
3.If the light will not switch on or off
from either switch in a two way circuit -
(If the above does not solve this
problem) the wiring may be incorrect,
and requires re-checking. Check that
the wire connected to the L2terminal
of the two way switch has been
removed and reconnected to the C
CHANGING A LIGHT BULB
PROGRAMME PLANNER
ON
TIME
OFF
TIME
MO
TU
WE
TH FR A U
e.g PROG 1
20.10
23.06
X
X
X
X X X X
PROG No 2
PROG No 3
PROG No 4
PROG No 5
PROG No 6
TROUBLESHOOTING
PROBLEMS & SOLUTIONS
TECHNICAL DATA
Rated Voltage: 230V, AC 50Hz
Load: Max 400W–Min 40W + most
Low Energy (CFL) 11W &
above
Integral 2amp fuse
A
B
C
D
E
H
L
J
G
F
K
MMOODDEELL NNUUMMBBEERR:: TT4400SS--CC