Safety instructions:
This device has been designed and tested in accordance to the safety regulations for electronic devices.
However, its trouble-free operation and reliability cannot be guaranteed unless the standard safety measures and special safety
advises given in this manual will be adhered to when using it.
1. Trouble-free operation and reliability of the device can only be guaranteed if it is not subjected to any other climatic
If the device is transported from a cold to a warm environment condensation may result in a failure of the function. In such a
case make sure the device temperature has adjusted to the ambient temperature before trying a new start-up.
2. If there is a risk whatsoever involved in running it, the device has to be switched off immediately and to be marked
accordingly to avoid re-starting.
Operator safety may be a risk if:
there is visible damage to the device
the device is not working as specified
the device has been stored under unsuitable conditions
In case of doubt, please return device to manufacturer for repair or maintenance.
3. Warning: Do not use these product as safety or emergency stop devices, or in any other application where failure of the
product could result in personal injury or material damage.
Failure to comply with these instructions could result in death or serious injury and material damage.
Choice of Measuring Unit:
The measuring unit can be chosen by means of the slide switch at the right side of the instrument.
°C => slide switch up: The instrument shows the current temperature
% RH => slide switch down: The instrument shows the current humidity
System Messages:
In case of measuring range overruns, etc. according error messages are displayed:
Er. 1 = measuring range has been exceeded
Er. 2 = meas. values have fallen below perm. range
Er. 7 = System fault - the device has detected a system fault
Other Operational Functions:
a)
instrument can still be operated for a short period of time.
The battery has to be taken out, when storing device above 50°C.
It is recommended to take the battery out, when storing device for a longer period of time.
b) The humidity and temperature sensor are located in the protruding sensor head. Make sure that the openings are not soiled.
In case of soiling do not try to remove the dirt. Improper use may damage the sensors. Prevent any mechanical impact on
the device as this may also lead to a destruction of the sensors (supporting material glass or ceramics)!
Please note: In the sensor area there is ESD-sensitive. Never touch or hold sensor head!
c) In order to guarantee accurate measurements the device has to be adjusted to ambient temperature.
If necessary wait for the temperature of the device to adjust to the ambient temperature.
If this is not possible, please proceed as follows:
Move device around while holding it at an arm's length (fanning), to speed up the exchange of air and the temperature
adjustment process. As soon as the display value is steady, readings can be made. This procedure shall be used for
temperature and for humidity measurements.
d) If you hold the device during measurements your body heat as well as your breath will change the temperature and the
humidity. In order to minimise these factors, hold the device at as great a distance from the sensor as possible. Also try to
prevent your breath coming into contact with the sensor. For optimum measuring results put down device and read display
from a certain distance as soon as a constant measuring value is displayed.
Always take into account that any humidity measurements in an open space cannot be made to an accuracy of more than
0.1% due to factors such as movement in the air, temperature changes etc.
e) A calibration at the users site is not possible. To ensure highest accuracies it should be returned to the manufacturer every
12 months (when used in clean air) for checking or, if necessary: recalibration.
If desired a calibration certificate can be made (according to ISO 9000). Price upon request.
f) Probe tube and case are not 100% proof. If there are pressure differences between probe tube and case, there may be
made wrong measurings.
For measurings in channels with over/under pressure or strong air flow we recommend our measure instruments GMH3330
or GMH3350 with humidity probe TFS0100 or TFS0100E.