H53.0.02.6C-13 page 1 of 4
Operating Manual For Hygro-/Thermometer
GFTH200
Application range:
Quick-response measurement of atmospheric humidity, temperature and dew point temperature (resp. wet bulb temperature) in
EDP rooms, museums, churches, administrative and residential buildings, storage rooms, green houses, pools, production rooms,
for cooling technology and air conditioning as well as for building engineers and for the evaluation of damage to buildings etc.
Specification:
Measuring range: temperature: -25,0°C ... +70,0°C resp. -13,0 ... +158,0°F
humidity: 0,0 ... 100,0 %RH (recommended range for application: 11 to 90 %RH)
dew point temperature: -40,0 ... +70,0 °C resp. -40,0 ... +158,0°F (GFTH200 standard)
wet bulb temperature: -27,0 ... +70,0 °C resp. -16,6 ... +158,0°F (only for option: GFTH200 / FK)
Resolution: temperature: 0,1°C or 0,1°F (selectable)
humidity: 0,1 %RH
dew point temperature: 0,1°C or 0,1°F
wet bulb temperature: 0,1°C or 0,1°F
Accuracy: (±1 digit) temperature (internal): ± 0,5% of m. v. ± 0,1°C (same as Pt1000 1/3 DIN)
(at nominal temperature = 25°C) temperature (external): ± 0,1°C (device) ± probe accuracy
humidity: ± 2,5% RH (range: 11 to 90 %RH)
Measuring probe: temperature: Pt1000
humidity: capacitive polymer humidity sensor
Response time: T90 = 10 sec.
Terminal for external probe
:for connection on any Pt1000 probe with 3.5 mm mono plug.
(measuring range: -25.0 ... +70.0°C)
Offset- and scale: digital offset and scale adjustment
Display: approx. 13 mm high, 3½-digit LCD-display
Operation elements: 3 keys for ON/OFF, min-/max-value display, hold
Slide switch for selection of measuring range
Nominal temperature: 25°C
Operating conditions: electronics: -25 to 70°C; 0 to 80 %RH (non-condensing)
sensors: -25 to 70°C; 0 to 100 %RH.
Power supply: 9V battery type JEC 6F22 (in scope of supply)
Power consumption: approx. 100µA at 1 measuring / s (mode FAST)
(for standard type) approx. 55µA at 1 measuring / 2s
approx. 20µA at 1 measuring / 10s
approx. 9µA at 1 measuring / 60s
Low battery warning: "BAT" automatically displayed if battery is low
Auto off function: when the Auto Off Function is activated, the device switches
automatically off, if keypad is not attended for a longer time
(selectable 1..120min).
Min-/Max-value memory: Min and max measured values are stored for all 3 measuring ranges.
Hold key:
Housing: impact resistant ABS-housing: approx.106 x 67 x 30 mm (HxWxD), in addition, sensor head
protruding vertically, length 35 mm, diameter 14 mm, overall length 141 mm.
Weight: approx. 135g incl. battery
EMC: The device corresponds to the essential protection ratings established in the Regulations of the
Council for the Approximation of Legislation for the member countries regarding electromagnetic
compatibility (2004/108/EG).
Additional fault: <1%
GREISINGER electronic GmbH
WEEE-Reg.-Nr. DE93889386