Technical Data
Functioning Principle
This Avensys mixing valve is a single lever
mixer with ceramic cartridge. Lifting the lever
opens water flow. Turning to the left in-
creases temperature and to the right de-
creases temperature. Shutting off the single
lever mixer is possible in any temperature
position.
Hot water limitation is possible by installing
the attached temperature limiter.
This product is supplied with connectors to fit
ø15mm pipework. Connection should be hot
left, cold right as viewed from the operating
position. The product is preassembled.
Plumbing Systems
This single lever mixer is suitable for
installation with:
•Gravity-fed plumbing systems with an
open vented hot water cylinder
•Cold water storage cistern
•Mains pressure unvented and instantan-
eous thermal hot water storage systems
•Multi-point gas water heaters
•Combination boilers with a modulating hot
water output
To maintain sufficient hot water output
ensure the combination boiler temperature
setting is on high.
Supply Pipework
Ensure the supply pipework is thoroughly
flushed before installing the mixing valve.
GROHE recommends installing isolating
valves upstream of the mixing valve for
servicing purposes.
New Water Regulations
This GROHE-product should be installed to
comply with the New Water Regulations
covering backflow prevention. It must also
be installed in accordance with local bye-law
requirements.
Specification
•Exposed single lever shower mixer,
concealed or exposed supplies
•Flow pressure
- Low pressure 0.1 - 1 bar
- High pressure 1 - 5 bar
Greater than 5 bar, fit pressure reducing
valve
•Avoid major pressure differences between
hot and cold water supply
- If the pressure difference between hot
and cold water supply is higher than
1 bar install attached green flow limiter
(7 l/min) in the cold water connection
elbow
•Max. operating pressure 10 bar
•Max. test pressure 16 bar
•Mixed water flow rate without downstream
resistance:
•Temperature
- Max. (hot water inlet) 80 °C
- Recommended (for economy) 60 °C
- Max. outlet temperature can be pre-set
using the adjustable temperature limiter.
•Water connection hot - LH
cold - RH
•Non reversible cartridge
Pressure 0.1 0.2 0.3 0.4 0.5 0.6 bar
Flow rate 10.2 14.4 17.7 20.4 22.8 25 l/min