Haws 1920FR Guide

06/22 Model 1920FR Page 1 of 7
1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424
E-mail: haws@hawsco.com website: www.hawsco.com
No. 0510000491 (6)
Model 1920FR
DrinkingFountain
INSTALLATION, OPERATION
&
MAINTENANCE INSTRUCTIONS
LIMITED WARRANTY
HAWS warrants that all of its products are guaranteed against defective material or poor workmanship for
a period of one year from the date of shipment. The foregoing notwithstanding, HAWS warrants certain
specificproductsor components thereof for an adjusted period.A listof these excepted products and
components and a description of their respective warranty terms may be found here:
www.hawsco.com/warranty. HAWS’liability under this warranty shall be discharged by furnishing without
charge F.O.B. HAWS factory any goods, or part thereof, which shall appear to the Company upon
inspection to be of defective material or not of first-class workmanship,provided that a claim is made in
writing to Companywithin a reasonable period after receiptof the product. Where claims for defects are
made, the defective part or parts shall be delivered to the Company, prepaid,for inspection. HAWS shall
not be liable forthe cost of repairs, alterations or replacements,or the labor required to implement them,or
for any expense connected therewith made by the owner or owner’s agents, except upon written authorit y
from HAWS. HAWS shall not be liable for any damages caused by defective materials or poor
workmanship,exceptforreplacements,as provided above.Buyeragrees that HAWShas made no other
warranties either express or implied in addition to those above stated, exceptthat of title with respect to
any of the products or equipmentsold hereunder and that HAWSshall not be liable for general, special,
incidental, or consequential damages claimed to arise under the contract of sale.
Equipment manufactured by HAWSis warranted to function if installation and maintenance instructions
provided are adhered to.The units also must be used for the purpose for which they were intended. Any
HAWS emergency equipment is intended to supplement first-aid treatment. Due to widely varying
conditions, HAWScannot guarantee that the use of this emergency equipmentwill preventserious injury
or the aggravation of existing orprior injuries.
EXCEPT AS EXPRESSLY STATED HEREIN, HAWS HEREBY DISCLAIMS ALL WARRANTIES,
WHETHER EXPRESS OR IMPLIED, ARISING BY LAW OR OTHERWISE, INCLUDING WITHOUT
LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE. THIS WARRANTY MAY NOT BE MODIFIED OREXTENDED WITHOUTTHE
WRITTEN CONSENT OF HAWS. REMEDIES AND REPLACEMENTS STATED HEREIN ARE
EXCLUSIVE. IN NO EVENT SHALL HAWS BE LIABLE FOR ANY SPECIAL, PUNITIVE,
CONSEQUENTIAL OR INCIDENTAL DAMAGES TO ANY PERSON INCLUDING BUT NOT LIMITED TO
DAMAGES FOR LOSS OF USE OR PROFITS, SUBSTITUTE PRODUCTS OR COSTS, PROPERTY
DAMAGE, OR OTHER MONETARY LOSS.
NOTE TO INSTALLER: Please leave this information with the Maintenance Department.
SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS
MODEL PLEASE CALL:
TECHNICAL SUPPORT: 1-800-766-5612
FOR CUSTOMER SERVICE: 1-888-640-4297

06/22 Model 1920FR Page 2 of 7
REQUIRED TOOLS: Tubing cutter, 3/32” and 5/32” hex key set, adjustable wrench or
socket.
LOCATION OF UNIT: The Model 1920FR bottle filler water dispenser can be installed in
various applications. Possible installations include indoor over an existing single or dual
drinking fountain, outdoors over an existing single or dual fountain, or as a stand-alone wall-
mounted bottle filler. When installing this unit, local, state or federal codes should be adhered
to.
SUPPLY LINE: The minimum recommended line size is 3/8"O.D. copper or plastic tubing
with 30-90 psi (2-6 ATM) pressure. Where sediment or mineral content is a problem, an inlet
filter is recommended.
PLUMBING CONNECTIONS: Inlet is 3/8“O.D. push-in type fitting.
MAINTENANCE: Referto6521FR operation and maintenance sheet formore information.
INSTALLATIONPROCEDURE
GENERALNOTES:
1. For all plastic push-in type fitting connections, only connect NSF-61 copper or
plastic tubing. Stainless steel orglass tubing is not recommended. The
followingassembly instructions must be followedto ensure a watertight
connection:
a. Cut tubingsquare and clean.
b. Markfrom end of tube the length of insertion (See table below).
c. Push tube into the fitting until it bottoms out.
d. Toremove, depress collet and pull tubing out.
TubeSizes
O.D.
Tolerance
Insertion Depth
3/8”
±.005”
3/4”
BOTTLERFILLER BRACKET:
If installing the bottler filler in new construction, use Model 6700 Mounting Plate. Follow the
installation instructions supplied with the 6700 formounting dimensions. ReferencePage 5-7 of
this documentfor 1920FR button height when mounted over differentHaws drinking fountains.
(Note: Mounting Hardware is only supplied with the 6700 Series Mounting Plates and not the
Bottle Filler Water Dispensers).
If installing as a retrofit in old construction, it is recommended to use Model 6700 Mounting Plate
behind the finished wall. If that is not possible, it is recommendedto install wood stud cross-
braces behind the wall and mount the 1920FR directly to the wood support. If that is not
possible, Model 6700R Retrofit Plate may be used. Follow the installation instructions supplied
with the 6700R. (Note: Mounting Hardwareis only supplied with the 6700 Series Mounting
Plates and not the Bottle Filler Water Dispensers).
If installing as a stand-alone bottle filler, use the mounting hole location diagram on Page 5 and
bolt the 1920FR securely to the wall. (Note: Mounting Hardware is not supplied with the Bottle
Filler Water Dispensers).

06/22 Model 1920FR Page 3 of 7
WATER LINE:
Referto 6521FR Manual forwater line connection instructions. Referto 6518FR Manual for
water line connection instruction in pedestal installation. NOTE: The 1920FR is shipped with
laminar flow screens in the dispensing nozzle. In cold temperatures remove laminar screens to
prevent water from freezing and clogging the supply line.
TROUBLESHOOTING1920FR
PROBLEM
REPAIR CHECKLIST
Insufficient bubbler flow.
1a.
Check that inlet screwdriver stop valve is wide
open (customer supplied). Turn
counterclockwise.
b.
Verify minimum 30 psi flowing supply pressure.
c.
Adjust valve to increase flow. See6518FR/
6521FR Valve Manual.
d.
Clean screens (inside nozzle body). Unscrew
nozzle insert and very gently activate water
supply to pop out qty. 3screens (be careful not to
lose screens). Remove any debris clogging the
screen openings and place back into nozzle body.
Reassemble nozzle insert.
For more information about Haws products, see our website: www.hawsco.com
© 2022 Haws®Corporation –All Rights Reserved
HAWS® and other trademarks used in these materials are the exclusive property of Haws Corporation.

PARTS BREAKDOWN
APPROVED
DRAWN
PART NUMBER
SCALE: SHEET OF
REVISION
DRAWING TYPE: SIZE: A
BYECN NO.
PAGE
DATE
DATE
ECN:
REVISED PER
CHKD
Haws Corporation - All Rights Reserved
HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation.
C
R
MODEL(S)
1455 KLEPPE LANE
SPARKS, NEVADA 89431
(775) 359-4712 FAX (775) 359-7424
E-MAIL: HAWS@HAWSCO.COM
WEBSITE: WWW.HAWSCO.COM
ITEM DESCRIPTION
THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS
MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.
WHEN ORDERING PARTS PLEASE SPECIFY MODEL NUMBER.
PART NO.
MJ
06/08/16
6
0510000491
1920FR
1:14
11
FV
07/08/22
5081
JS
4 OF 7
PARTS BREAKDOWN
5799
2022
FV
1
1PUSH BUTTON ASSEMBLY 5881PBA

APPROVED:
DRAWN:
PART NUMBER
SCALE: SHEET OF
REVISION
DRAWING TYPE: SIZE: A
BY:ECN NO.
PAGE
DATE:
DATE:
ECN:
REVISED PER
CHK'D.:
Haws Corporation - All Rights Reserved. HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation.
CR
MODEL(S)
1455 KLEPPE LANE
SPARKS, NEVADA 89431
(775) 359-4712 FAX (775) 359-7424
E-MAIL: HAWS@HAWSCO.COM
WEBSITE: WWW.HAWSCO.COM
THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS
MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.
DS
05/25/16
6
0510000491.D
1920FR
N/A
13
FV
07/08/22
5081
JS
5 of 7
INSTALLATION
5799
2022
FV
1920FR MOUNTING HOLE LOCATIONS
NOTES:
1THIS BOTTLE FILLER REQUIRES THE USE OF MODEL 6521FR
FREEZE RESISTANT VALVE ASSEMBLY (SOLD SEPERATELY
2VALVE ASSEMBLY MUST BE INSTALLED IN A WARM AREA. PROVISIONS
SHOULD BE MADE TO ALLOW ACCESS TO THE ACCESS PANEL.
3. SEE SEPERATE INSTALLATION DRAWINGS FOR FOUNTAINS, MOUNTING PLATES,
4. WHEN INSTALLING THIS UNIT, LOCAL, STATE OR FEDERAL CODES SHOULD
BE ADHERED TO. FOR INSTALLATION HEIGHTS OTHER THAN SHOWN,
DIMENSIONS MARKED (*) MUST BE ADJUSTED ACCORDINGLY.
BACKPANELS, AND DRIP TRAY. HOLD ROUGH-IN DIMENSIONS
±
1/8" (3.2mm).
OR AS PART OF PRODUCT BUNDLES).

APPROVED:
DRAWN:
PART NUMBER
SCALE: SHEET OF
REVISION
DRAWING TYPE: SIZE: A
BY:ECN NO.
PAGE
DATE:
DATE:
ECN:
REVISED PER
CHK'D.:
Haws Corporation - All Rights Reserved. HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation.
CR
MODEL(S)
1455 KLEPPE LANE
SPARKS, NEVADA 89431
(775) 359-4712 FAX (775) 359-7424
E-MAIL: HAWS@HAWSCO.COM
WEBSITE: WWW.HAWSCO.COM
THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS
MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.
MJ
02/13/17
6
0510000491.D
1920FR
N/A
23
FV
07/08/22
5081
JS
6 of 7
INSTALLATION
5799
2022
FV
NOTES:
SEE SHEET 1
6521 VALVE ASSEMBLY
ACCESS PANEL
6521FR FREEZE RESISTANT
VALVE ASSEMBLY
(NOT SUPPLIED)
FOR BOTTLE FILLER
CONNECT AIR LINE TO BOTTLE
FILLER PUSH BUTTTON, TRIM TO FIT.
7/8" OD INSULATING TUBING (MUST COVER
ENTIRE SUPPLY TUBING, FROM THE
NOZZLE TO MODEL 6521FR ASSEMBLY)
TRIM TO FIT.
3/8" OD POLYPROPYLENE TUBING
(CONNECT TO NOZZLE WITH
SUPPLIED PUSH-IN ELBOW,
1-1/4" IPS
WASTE (NOT
SUPPLIED)
1/2" IPS SUPPLY
(NOT SUPPLIED)
(47-5/8")
(1210mm)
BUTTON
HEIGHT
27"
686mm
FOR ADA
COMPLIANCE
BP15
BACK PANEL
(NOT SUPPLIED)
6469
DRIP
TRAY
(NOT
SUPPLIED)
438mm
17-1/4"
34-1/2"
876mm
37-1/2"
952mm
39-1/2"
1003mm
(4")
(102mm)
DEPTH
OF BOX
INSTALLATION SHOWN ABOVE HAWS MODEL 1109FR
BP3
BACK PANEL
(NOT
SUPPLIED)
6700 MOUNTING PLATE
(BEHIND FINISH WALL)
- OR -
6700R RETROFIT PLATE
(ON TOP OF FINISH WALL)
BOTH SOLD SEPARATELY
DRINKING
FOUNTAIN
SHOWN FOR
REF. ONLY
(NOT SUPPLIED)
6521FR FREEZE RESISTANT
VALVE ASSEMBLY
( NOT SUPPLIED)
FOR DRINKING FOUNTAIN
21
2
1920FR
TRIM TO FIT.
(7")
(178mm)

APPROVED:
DRAWN:
PART NUMBER
SCALE: SHEET OF
REVISION
DRAWING TYPE: SIZE: A
BY:ECN NO.
PAGE
DATE:
DATE:
ECN:
REVISED PER
CHK'D.:
Haws Corporation - All Rights Reserved. HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation.
CR
MODEL(S)
1455 KLEPPE LANE
SPARKS, NEVADA 89431
(775) 359-4712 FAX (775) 359-7424
E-MAIL: HAWS@HAWSCO.COM
WEBSITE: WWW.HAWSCO.COM
THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS
MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.
MJ
02/13/17
6
0510000491.D
1920FR
N/A
33
FV
07/08/22
5081
JS
7 of 7
INSTALLATION
5799
2022
FV
INSTALLATION SHOWN ABOVE HAWS MODEL 1119FR
27"
686mm
34-1/2"
876mm
37-1/2"
952mm
39-1/2"
1003mm
1920FR
17-1/4"
438mm
NOZZLE WITH SUPPLIED
TUBING (CONNECT TO
3/8" OD POLYPROPYLENE
7/8" OD INSULATING TUBING (MUST
COVER ENTIRE SUPPLY TUBING,
FROM THE NOZZLE TO MODEL
6521 ASSEMBLY, TRIM TO FIT.
CONNECT AIR LINE TO BOTTLE
FILLER PUSH BUTTTON, TRIM TO FIT.
PUSH-IN ELBOW, TRIM TO FIT.
1/2" IPS SUPPLY
(NOT SUPPLIED)
1-1/4" IPS
WASTE (NOT
SUPPLIED)
6521 VALVE ASSEMBLY
ACCESS PANEL
NOTES:
SEE SHEET 1
2
6700 MOUNTING PLATE
(BEHIND FINISH WALL)
- OR -
6700R RETROFIT PLATE
(ON TOP OF FINISH WALL)
BOTH SOLD SEPARATELY
DRINKING
FOUNTAINS
SHOWN FOR
REF. ONLY
(NOT SUPPLIED)
DUAL
BACK PANEL
(NOT SUPPLIED)
(47-5/8")
(1210mm)
BUTTON
HEIGHT
FOR ADA
COMPLIANCE
BP32
BACK PANEL
(NOT SUPPLIED)
6469
DRIP
TRAY
(NOT
SUPPLIED)
6521FR FREEZE RESISTANT
VALVE ASSEMBLY
(NOT SUPPLIED)
FOR BOTTLE FILLER
21
6521FR
FREEZE RESISTANT
VALVE ASSEMBLY
( NOT SUPPLIED)
FOR DRINKING FOUNTAIN
(4")
(102mm)
DEPTH
OF BOX
(7")
(178mm)
Table of contents
Other Haws Outdoor Fountain manuals
Popular Outdoor Fountain manuals by other brands

Jeco
Jeco FCL028 quick start guide

Campania International
Campania International Longmeadow Assembly instructions

CLIMAQUA
CLIMAQUA SPUTNIK instructions

Oase
Oase Aquaswim 900 operating instructions

Xbrand
Xbrand GE2512FTGR instruction manual

Most Dependable Fountains
Most Dependable Fountains 545 SM Operation manual

Bernini
Bernini TRAPANI owner's manual

Campania International
Campania International Mini Element with Zen Frog Fountain FT-253 Assembly instructions

Elkay
Elkay Space-ette FLEXI-GUARD FDD Installation, care & use manual

Campania
Campania Chatsworth FT-141 quick start guide

Britex
Britex DIWR installation guide

Campania International
Campania International GFRCFT-1106 Assembly instructions