AB1701EN_SA Rev. 03 / 12.2022 5/72
20.1 Centrifugation with preselected time..........................................................................................................23
20.2 Continuous operation.................................................................................................................................24
20.3 Short-time centrifugation............................................................................................................................24
21 Change the settings during the centrifugation run.............................................................................................24
22 Integral RCF......................................................................................................................................................25
22.1 Query integral RCF....................................................................................................................................25
22.2 Activate or deactivate the integral RCF display..........................................................................................25
23 Emergency Stop................................................................................................................................................25
24 Cycle counter ....................................................................................................................................................26
24.1 After starting the first centrifugation run, enter the maximum permitted number of rotor cycles
or deactivate the cycle counter ..................................................................................................................26
24.2 Reset cycle counter to "0" and enter the maximum permitted number of rotor cycles ...............................27
24.3 Activating or deactivating the cycle counter...............................................................................................28
25 Activating/deactivating the "Dual time mode" function" .....................................................................................28
26 Activating or deactivating start-up and run-down times.....................................................................................29
27 Acoustic signal ..................................................................................................................................................29
28 Displayed centrifugation data after switch-on....................................................................................................30
29 Set temperature unit (only for centrifuge with refrigeration)...............................................................................30
30 Setting program locks........................................................................................................................................31
31 PIN (Personal Identification Number)................................................................................................................31
31.1 Setting or changing the PIN.......................................................................................................................32
31.2 Procedure in the event that PIN is lost.......................................................................................................32
32 Centrifuge address............................................................................................................................................32
33 Query the operating hours, centrifugation runs and cycle counter ....................................................................33
34 Query the system information............................................................................................................................33
35 Immediate display of centrifugation data after switch-on...................................................................................33
36 Cooling (only in centrifuges with cooling)..........................................................................................................34
36.1 Standby-cooling .........................................................................................................................................34
36.2 Precooling of the rotor................................................................................................................................34
36.3 Time-controlled cooling..............................................................................................................................34
36.4 Prevent cooling being switched on during run-out .....................................................................................35
36.5 Temperature monitoring.............................................................................................................................35
37 Heating (only on centrifuges with heating/cooling option) .................................................................................36
38 Relative centrifugal force (RCF)........................................................................................................................36
39 Centrifugation of materials or mixtures of materials with a density higher than 1.2 kg/dm3...............................37
40 Rotor recognition...............................................................................................................................................37
41 Emergency release ...........................................................................................................................................37
42 Maintenance and servicing................................................................................................................................38
42.1 Centrifuge (housing, lid and centrifuging chamber)....................................................................................38
42.1.1 Surface cleaning and care ..................................................................................................................38
42.1.2 Surface disinfection.............................................................................................................................38
42.1.3 Removal of radioactive contaminants.................................................................................................38
42.2 Rotors and Attachments.............................................................................................................................39
42.2.1 Cleaning and care...............................................................................................................................39
42.2.2 Disinfection .........................................................................................................................................39