manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Honeywell
  6. •
  7. Security System
  8. •
  9. Honeywell NOTIFIER PAN1-PLUS-EN3 User manual

Honeywell NOTIFIER PAN1-PLUS-EN3 User manual

Other Honeywell Security System manuals

Honeywell Domonial User manual

Honeywell

Honeywell Domonial User manual

Honeywell ADEMCO VISTA-10P User manual

Honeywell

Honeywell ADEMCO VISTA-10P User manual

Honeywell Galaxy 2 Series User manual

Honeywell

Honeywell Galaxy 2 Series User manual

Honeywell Ademco VISTA-20P User manual

Honeywell

Honeywell Ademco VISTA-20P User manual

Honeywell PID-95P Guide

Honeywell

Honeywell PID-95P Guide

Honeywell INTELLIGUARD 9000 User manual

Honeywell

Honeywell INTELLIGUARD 9000 User manual

Honeywell LYNX Touch Security System User manual

Honeywell

Honeywell LYNX Touch Security System User manual

Honeywell LYNX Touch Security System User manual

Honeywell

Honeywell LYNX Touch Security System User manual

Honeywell 013002 User manual

Honeywell

Honeywell 013002 User manual

Honeywell ESSER TAM User manual

Honeywell

Honeywell ESSER TAM User manual

Honeywell Galaxy Dimension User manual

Honeywell

Honeywell Galaxy Dimension User manual

Honeywell FG8MS User manual

Honeywell

Honeywell FG8MS User manual

Honeywell LYNX Touch Security System User manual

Honeywell

Honeywell LYNX Touch Security System User manual

Honeywell VISTA-32FBPT User manual

Honeywell

Honeywell VISTA-32FBPT User manual

Honeywell FBII OMNI 600 User manual

Honeywell

Honeywell FBII OMNI 600 User manual

Honeywell ADEMCO LYNXRIEN-EA User manual

Honeywell

Honeywell ADEMCO LYNXRIEN-EA User manual

Honeywell VISTA 15P - Ademco 6 Zone Control Panel Operating instructions

Honeywell

Honeywell VISTA 15P - Ademco 6 Zone Control Panel Operating instructions

Honeywell ADEMCO VISTA-40 User manual

Honeywell

Honeywell ADEMCO VISTA-40 User manual

Honeywell 2202 User manual

Honeywell

Honeywell 2202 User manual

Honeywell 6272CV User manual

Honeywell

Honeywell 6272CV User manual

Honeywell Gamewell-FCI E3 Series User manual

Honeywell

Honeywell Gamewell-FCI E3 Series User manual

Honeywell Gamewell-FCI Velociti MS-7AF User manual

Honeywell

Honeywell Gamewell-FCI Velociti MS-7AF User manual

Honeywell Lynx Plus Series Assembly instructions

Honeywell

Honeywell Lynx Plus Series Assembly instructions

Honeywell Fire-Lite Alarms ANN-80 Series Technical manual

Honeywell

Honeywell Fire-Lite Alarms ANN-80 Series Technical manual

Popular Security System manuals by other brands

Polon-Alfa 4000 Installation and maintenance manual

Polon-Alfa

Polon-Alfa 4000 Installation and maintenance manual

Nexcom NViS 14162 Series user manual

Nexcom

Nexcom NViS 14162 Series user manual

Eminent EM8670 Quick install

Eminent

Eminent EM8670 Quick install

urmet domus alpha 1060 INSTALLATION AND USE BOOKLET

urmet domus

urmet domus alpha 1060 INSTALLATION AND USE BOOKLET

SmartPool YardGuard YG03 manual

SmartPool

SmartPool YardGuard YG03 manual

DSC PC5964 Mounting instructions

DSC

DSC PC5964 Mounting instructions

Secure USAB-1 operating instructions

Secure

Secure USAB-1 operating instructions

B&B 480 SERIES Operation & maintenance manual

B&B

B&B 480 SERIES Operation & maintenance manual

ADEMCO VISTA-20P Series Installation and setup guide

ADEMCO

ADEMCO VISTA-20P Series Installation and setup guide

Inner Range Concept 2000 user manual

Inner Range

Inner Range Concept 2000 user manual

Johnson Controls PENN Connected PC10 Install and Commissioning Guide

Johnson Controls

Johnson Controls PENN Connected PC10 Install and Commissioning Guide

Aeotec Siren Gen5 quick start guide

Aeotec

Aeotec Siren Gen5 quick start guide

Swann SW-P-MC2 Specifications

Swann

Swann SW-P-MC2 Specifications

Ecolink Siren+Chime user manual

Ecolink

Ecolink Siren+Chime user manual

EDM Solution 6+6 Wireless-AE installation manual

EDM

EDM Solution 6+6 Wireless-AE installation manual

Siren LED GSM operating manual

Siren

Siren LED GSM operating manual

Detection Systems 7090i Installation and programming manual

Detection Systems

Detection Systems 7090i Installation and programming manual

FRIEDLAND MA10 Installation and operating instructions

FRIEDLAND

FRIEDLAND MA10 Installation and operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Installation and user Manual
Fire alarm devices - Acoustic alarm device
PAN1-PLUS-EN3
General features:
The panel PAN1-PLUS-EN3 is a device conceived for acoustic signaling of fires.
All materials utilized to produce it comply to fire system requirements and the housing is built with fireproof
materials.
The alarm device has to be installed by qualified personnel only, respecting all installation norms and
adequate distances and highness to get the best optical and acoustic performances.
TECHNICAL DATA
Max Current absorption
50mA @Vdc=24V
Nominal Voltage supply
24Vdc (from 20Vdc to 30Vdc)
Max Power absorption
1.2W
Max current absorption for sound
20mA +/-5mA
Main sound frequency (average)
Sound 1 983 Hz
Main sound pattern
Sound 1 Pulsed at 1.2 Hz
Max level SPL @1 m
See Diagram 1
Available Patterns
4 available patterns: 1 modulated, 1 pulsed, 1 bitonal,1
continuous
Operating temperature
From -10 °C to +55°C
Command from the control panel
Polarity inversion
Enclosure protection degree
IP21C (Type A, for indoor use)
Size (WxHxD)
307 x 117 x 55 mm
Weight
508 gr
Standards
EN54-3:2001 + A1:2002 + A2:2006
S-312.1-PAN1P-EN3-ENG Rev. A.2 06/2019
PAN1-PLUS-EN3
Acoustic alarm device
Diagram 1 (Sound power distribution):
PAN1
-PLUS-EN3
horizontal degrees
DIP 5ON 6OFF 97dB
PAN1
-PLUS-EN3
vertical degrees
DIP 5ON 6OFF 97dB
DIP 3ON 4ON
DIP 3ON 4OFF
DIP 3OFF 4ON
DIP 3OFF 4OFF
DIP 3ON 4ON
DIP 3ON 4OFF
DIP 3OFF 4ON
DIP 3OFF 4OFF
S1 S2 S3 S4 S1 S2 S3 S4
min dB(A)
@1m
min dB(A)
@1m min dB(A) @1m min dB(A) @1m min dB(A) @1m min dB(A)
@1m
min dB(A)
@1m min dB(A) @1m
15 90 94 92 90 15 85 96 87 83
45 93 96 98 94 45 96 97 99 96
75
92
97
93
91
75
101
100
104
101
105 92 97 93 91 105 96 98 100 97
135 93 96 95 93 135 103 100 105 102
165 96 95 99 96 165 93 95 95 94
PAN1
-PLUS-EN3
horizontal degrees
DIP 5OFF 6OFF 101dB
PAN1
-PLUS-EN3
vertical degrees
DIP 5OFF 6OFF 101dB
DIP 3ON 4ON DIP 3ON 4OFF
DIP 3OFF 4ON DIP 3OFF 4OFF DIP 3ON 4ON DIP 3ON 4OFF DIP 3OFF 4ON DIP 3OFF 4OFF
S1
S2
S3
S4
S1
S2
S3
S4
min dB(A) @1m
min dB(A)
@1m min dB(A) @1m min dB(A) @1m
min dB(A)
@1m min dB(A) @1m min dB(A) @1m min dB(A) @1m
15
94
98
98
96
15
90
100
92
88
45 99 100 101 99 45 102 101 102 102
75 97 101 97 97 75 107 104 108 107
105 97 100 97 97 105 102 101 102 102
135
99
100
99
98
135
108
104
109
108
165 101 99 102 101 165 100 98 99 99
PAN1
-PLUS-EN3
horizontal degrees
DIP 5OFF 6ON 94dB
PAN1
-PLUS-EN3
vertical degrees
DIP 5OFF 6ON 94dB
DIP 3ON 4ON
DIP 3ON 4OFF
DIP 3OFF 4ON
DIP 3OFF 4OFF
DIP 3ON 4ON
DIP 3ON 4OFF
DIP 3OFF 4ON
DIP 3OFF 4OFF
S1 S2 S3 S4 S1 S2 S3 S4
min dB(A) @1m min dB(A)
@1m min dB(A) @1m min dB(A) @1m min dB(A)
@1m min dB(A) @1m min dB(A) @1m min dB(A) @1m
15 88 91 89 87 15 82 93 84 78
45 89 92 93 90 45 92 93 95 93
75
88
93
90
88
75
97
97
100
98
105 87 94 88 87 105 93 95 95 93
135 90 92 92 90 135 99 97 100 99
165 91 92 94 92 165 88 92 91 89
Sound S2 – DIP - 5 OFF 6 OFF
UP
DOWN
104dB
RIGHT
LEFT
97dBA
Fixing Holes
Torx
Screws
Pict. 1
Pict. Pict.2
Installation:
Connection
Connect the main output with “polarity inversion” to positive (A+) and negative (A-) terminals (see. Pict.1)
with a certified wire. Moreover, insert the end-of-line R resistor between the “A+” terminal and the “A-”
terminal. The value of the end-of-line R resistor depends on the kind of main installed, and it is indicated in
the main installation manual.
Terminal SYNC (Synchronism): if required, connect together the terminal SYNC of the devices to
synchronize them.
Terminals B+ B- (Buzzer Mute): if required, applying 24Vcc between B+ and B- or short-circuiting B- with A-,
the buzzer is silenced.
Selection of backlight mode
DIP switch 1-2
Description
OFF – OFF (Default) Backlight blinking at 0.6 Hz
ON - OFF Backlight OFF
OFF -ON Backlight OFF
ON - ON Backlight ON
Selection of sound pattern and power
DIP switch 3-4
Description
OFF - OFF (Default) 983Hz pulsed at 1.2 Hz
ON - OFF Sweep from 1200 Hz to 500 Hz at 1.2Hz
OFF -ON 983-750 Hz alternate at 1.2Hz
ON- ON 983Hz continuous
Sound level
DIP switch 5-6
MAX Sound Level at 1 m
OFF-OFF (Default)
101 dB
ON - OFF 97 dB
OFF -ON 94 dB
ON - ON Sound disabled (NOT COMPLIANT TO EN54-3)
Wall fixing:
Fix the device on the wall through the 4 holes on its base (see Pict. 2).
Use an adapter to connect all cables in case of a system with external tubes.
The device must be placed with the long side parallel to the floor, and the acoustic speaker on the bottom.
SYNCRONISM
R
POSITIVE IN STANDBY
CONNECT THE MAIN
OUTPUT WITH POLARITY
INVERSION
NEGATIVE IN STANDBY
MUTE BUZZER
In case of any modification of one or more of the above topics, the certification will be not valid.
Dop available on web site www.notifier.it
Warranty: All Notifier products have 1 year of guarantee.
1293
Notifier s.r.l. Via A: Grandi, 22, 20097 S. Donato Milanese (MI) Italy
18
DoP 1293 - CPR – 0602
EN54-3
PAN1-PLUS-EN3
FIRE ALARM DEVICES – ACOUSTIC ALARM DEVICE
Intended for use in fire detection and fire alarm systems in and around buildings
TYPE A: for indoor use
Other technical data: see supplier’s technical dossier.
Essential characteristics
Performance
Performance under fire conditions
Pass
Operational reliability Pass
Durability of operational reliability and response delay, temperature
resistance
Pass
Durability of operational reliability, humidity resistance
Pass
Durability of operational reliability, shock and vibration resistance
Pass
Durability of operational reliability, corrosion resistance Pass
Durability of operational reliability, electrical stability
Pass
Durability of operational reliability, resistance to ingress
Pass
ATTENTION:
Please note that all installation indications here above must be carefully respected to prevent the device from loosing
its standard compliance.
Numero Assistenza Tecnica: 039-9301410