INSTRUCTIONS
5
HOW TO CUSTOMIZE SETTINGS
UP - Press buon to increase seng
DOWN - Press buon to decrease seng
ENTER/RESET - Press buon, hold for 3 seconds to restart mer or to adjust the seng. The mer will
always start in the “ON” cycle.
TEMPERATURE DISPLAY - Press and hold both the UP and DOWN buon for 3 seconds to change
display. C for Celsius and F for Fahrenheit.
DAYTIME SETTING - To set the Day temperature press the TEMP DAYTIME SETTING, dAY__F will be
displayed. To change sengs press the UP and DOWN buons. Press ENTER to accept new seng.
NIGHT SETTING - To set the Night temperature press TEMP NIGHT SETTING buon, Nit__F will be
displayed. To change sengs press the UP and DOWN buons. Press ENTER to accept new seng.
TEMP DEADBAND – Press this buon to change the Temp deadband. To set the deadband, press
TEMP DEAD BAND. d.b_ _ _F will be displayed. To change sengs, press the UP and DOWN buons.
Press ENTER to accept new seng.
HUMIDITY SETTING - There is a day humidity seng and a night humidity seng.
• To set the daytime humidity, press the HUMIDITY SETTING button. day_rH will be displayed.
Press the UP or DOWN button to change daytime humidity setting. Press ENTER to accept new
setting.
• To set the nighttime humidity, press the HUMIDITY SETTING button a second time nit_rH will be
displayed. Press the UP or DOWN button to change the nighttime humidity setting. Press ENTER
to accept new setting.
HUMIDITY MODE – Use this buon to select humidify or dehumidify. Press Humidity mode and the
display will read the current seng, either humidify (rH Incr) or dehumidify (rH dEcr). Press the UP
and DOWN buons to change the seng. Press ENTER to accept new seng.
HUMIDITY DEADBAND - Pressing HUMIDITY DEAD BAND will display the current seng. Press the
UP or DOWN buons to change the seng. Press ENTER to accept new seng.
CO2ON TIME - To change the mer sengs, press the UP or DOWN buon to change hours seng
(le 2 digits) then press ENTER to change to the minutes (center 2 digits), use UP or DOWN to change,
then press ENTER to advance to the seconds seng (right 2 digits). Pressing ENTER a nal me accepts
the new sengs.
CO2OFF TIME - Repeat the procedure above to change the CO2 OFF mer sengs.
TEMP/HUMIDITY LOCK - Use this funcon to interlock (COnnEct) or split (SPLit) humidity and
temperature. Press Temp/humidity lock buon to display the seng. Press the UP and DOWN buons
to change the seng. Press ENTER to accept new seng.
1. Select connect (COnnEct) if using venlang fans only for cooling and removing humidity. The
fan will turn on when the sensor detects a rise above the seng in either the humidity or
temperature.
2. Select split (SPLit) if using a venlang fan or AC unit as a cooling device and a dehumidier to
remove humidity. Each device is controlled independently. The cooling device will turn on when
the temperature rises above the seng and the dehumidier will turn on when the humidity rises
above the seng.