Hydrofarm Autopilot APC8200 User manual

APC8200
USER MANUAL
DIGITAL CO2CONTROLLER

APC8200 - USER MANUAL
OVERVIEW
Thank you for purchasing the Autopilot APC8200 Digital CO
2
Controller! Our products are packaged
and shipped with the utmost care. In the unlikely event that your item is incorrect, incomplete, or
unsasfactory, please contact us and we will resolve the issue.
PACKAGE CONTENTS
CO
2
Controller Unit
CO
2
Sensor with photocell
15’ Data cable
User Manual
Screws
WARNINGS
• To ensure safe operation, please read this manual carefully before installation and follow the
instructions.
• Store this manual in a secure place for future reference.
• WARNING: CHOKING HAZARD - Accessories contain small parts.
FEATURES AT A GLANCE
• CO
2
controller; Tracer (Data logger)
• Built-in Day/Night sensor
• Chart with variable time Zoom Levels
• 2-Channel Low Drift NDIR Sensor
• “Hold Home” function
OPERATING INSTRUCTIONS
Inial Setup: When rst unboxing, plug the piggyback into the power socket. If successfully connected,
3 things will happen while boong up:
1. Alarm will beep once.
2. Chart display will show the current soware version & “Warm Up”.
3. Main display will show a countdown from 10.
CO2GENERATOR
or REGULATOR
2

Once the countdown is complete, your product is ready to use. No addional setup or calibraon is
needed.
CO2, Set Center, Set Zone Readings
The device has three built-in main parameters: ambient carbon dioxide (7), Set Center value (6), and
Set Zone value (5). They are constantly displayed on screen.
TREND CHART ZOOM
Below is a table showing the available Zoom Levels for all CO
2
parameters, as well as the duraon of
each division for corresponding Zoom Levels:
The DOWN buon will toggle the available Zoom Levels for each parameter. Note that in addion to
the Zoom Levels for each parameter, there is an opon that will automacally cycle between the Zoom
Levels. This can be achieved by pressing DOWN unl icon (8) appears at the boom le of the chart.
1
9
2
3
4
5
7
8
6
1. CO2Chart
2. Max Reading of Chart
3. Min Reading of Chart
4. Audible Alarm On/O
5. CO2Zone value
(deadband seng)
6. CO2Center value
(Ideal CO2 level)
7. CO2Reading
8. Zoom Level of Time –
indicates the chart’s
mespan
9. Target Zone Indicator
Zoom Level (Time Span) (8) Time Per Division
1m (minute) 5sec /div
1h (hour) 5m/div
1d (day) 2h/div
1w (week) 0.5d/div
Auto Cycle Zoom Cycle
LCD DISPLAY
3

MAX/MIN
At the top right corner of the display, there are two numerical indicators: Max (2) and Min (3). As the
Zoom Level is changed, the Max and Min values will reect the maximum and minimum values on the
chart of the selected parameter. At startup, the unit will automacally display values for 1d (day) value.
AUTO DETECT DAY/NIGHT
The built-in photocell sensor can automacally detect whether it is Day or Night. It can override the
CO
2
control and shut o the CO
2
generator or regulator by turning o the output power during the
night. Conversely, if the Photo-Cell detects light and the CO
2
level is low, the device will start the CO
2
generator by turning on output power.
CO2OUTPUT CONTROL
Output power is on when the CO
2
concentraon is below Set Center+(1/2) Set zone, and o when
CO
2
concentraon is over Set Center-(1/2) Set zone. For example, if the Set Center is 1200 ppm, and
the Set zone is 400ppm, the output power will shut o when CO
2
over 1200+(1/2)*(400)=1400 ppm,
and power on when CO
2
below 1200-(1/2)*(400)=1000 ppm. In other words, if you want a ±100 ppm
deadband you should enter 200ppm here. That means the unit will allow a 100 ppm swing above or
below your Set Center CO
2
Seng.
HOLD HOME
To revert to start-up sengs at any point, hold ENTER for 3 seconds unl you hear audible beep. The
device will then revert to Home Seng, as if the power was reset, displaying “Back Home done.” Note
that this is not the same as Restore to factory sengs.
To clear all stored data in the chart you must Restore to factory sengs. To use Restore mode select
the Advanced Seng funcon and hold ENTER for 3 seconds unl an audible beep sounds.
Below is a table showing what main menu selecon is made by pressing MENU mulple mes as well
as their funcons. Note that the device will display “Done,” followed by the conrmed selecon if
selected correctly.
4

MAIN MENU FUNCTIONS
The Main Menu funcons can be toggled
through by selecng the MENU buon. If the
main menu is not selected, the menu LED will
remain o, leaving the UP buons to toggle
Zoom Levels, respecvely.
uS1 Set Center (Custom CO2 ppm seng)
uS2 Set Zone (Deadband)
uS3 Home (for General Plant)
uS4 Re-Calibrate
uS5 Advance Seng
Pressing MENU once will bring up the menu LED,
with ashing before the current choice.
To select the funcon, press ENTER when menu
selecon LED is ashing. Note that aer 1 minute
if nothing is pressed, the Main Menu LED will shut
o and the device will revert to the normal state.
POWER
DAY TIME
CO2OUTPUT
S1 Set Center
S2 Set Zone
(Deadband)
S3 Home
(for General Plant)
S4 Re-Calibrate
S5 Advance Setting
HOLD HOME 1 DAY
1 WEEK 1 HR
1 MIN
MENU
ENTER
LED DISPLAY
FUNCTION DIRECTIONS
S1 Set Center
By default , the Set Center value is 1200 ppm for general plant, Once Set
Center is selected (by pressing ENTER), use either UP or DOWN to toggle the
center value. Press ENTER one more me to conrm.
S2 Set Zone
(Deadband)
This funcon allows the user to set the Zone (Deadband). Once selected, Use
UP and DOWN to toggle to the set zone value. Press ENTER to conrm. Note
that the default value of set zone is 400 ppm. See CO2OUTPUT CONTROL for
seng a custom deadband.
S3 Home
(For General Plant)
This funcon for Home plant (General plant), Once selected, the Set Center
value is xed 1200 ppm, and Set Zone value is xed 400 ppm.
S4 Re-Calibrate
Use this funcon to calibrate your device with outside atmospheric CO2level
~ 400 ppm. Select this mode, hold ENTER for 3 seconds unl a beep and the
chart will read “Calibrang”, then place the device outside for 20 minutes. To
escape, press MENU. Make sure the device is far from a source of CO2, not
in direct sunlight, and not exposed to water. Step away from the unit during
calibraon.
S5 Advance Seng
This funcon toggles between 3 things when selected: This funcon toggles
between 3 things when selected:
• Audible Alarm On/Off
• Altitude Setting
• Restore Factory Setting
Restore Factory Seng will reset the device to factory sengs and erase all
stored data in the chart. To use Restore mode, hold ENTER for 3 seconds unl
an audible beep.
5

SPECIFICATIONS
Typical test condions, unless otherwise specied: Ambient Temp =73+/-3°F, RH=50%-70%,
Altude=0~100 meter
DISCLAIMERS
This device is not intended for workplace hazard CO
2
monitoring, nor intended as a denive monitor
for human or animal health instuons, life sustenance, or any medical-related situaon.
Hydrofarm and the manufacturer assume no responsibility for any damage or loss suered by the user
or any third party arising through the use of this product or its malfuncon.
Hydrofarm reserves the right to change the specicaons without noce.
MEASUREMENT SPECIFICATION
Operang Temperature 32°F to 122°F (0°C to 50°C)
Storage Temperature -4°F to 140°F (-20°C to 60°C)
Operang & Storage RH 0-95%, non-condensing
CO2Measurement
Accuracy at 0~3000 ppm ±50 ppm or ±5% of reading, whichever is greater
Accuracy over 3000 ppm ±7%
Repeatability 20 ppm at 400 ppm (standard dev. of 10 readings in 1 minute)
Measurement Range 0-5000 ppm
Display Resoluon 1 ppm (0-1000); 5 ppm (1000-2000); 10 ppm (>2000)
Temp Dependence ±0.2% of reading per °C or ±2ppm per °C, whichever is greater,
referenced to 25°C
Pressure Dependence 0.13% of reading per mmHg (corrected by user’s altude input)
Response Time <2 min for 63% of step change or <4.6 min for 90% step change
Warm-up Time <30 sec
Power input AC 100 ~ 240 VAC
Dimension Sensor Unit: 153x33x27mm (6.0"x1.3"x1.1")
Control Unit: 195x145x44mm (7.7"x5.7"x1.7")
Weight 700 g (24.7 oz)
6

NOTES
7

Hydrofarm.com
LIMITED WARRANTY
Hydrofarm warrants the APC8200 to be free from defects in materials and workmanship. The warranty
term is for 3 years beginning on the date of purchase. Misuse, abuse, or failure to follow instrucons is
not covered under this warranty. Hydrofarm’s warranty liability extends only to the replacement cost
of the product. Hydrofarm will not be liable for any consequenal, indirect, or incidental damages of
any kind, including lost revenues, lost prots, or other losses in connecon with the product. Some
states do not allow limitaon on how long an implied warranty lasts or the exclusion of incidental or
consequenal damages, so the above limitaons or exclusions may not apply to you. Hydrofarm will,
at our discreon, repair or replace the APC8200 covered under this warranty if it is returned to the
original place of purchase. To request warranty service, please return the APC8200, with original sales
receipt and original packaging, to your place of purchase. The purchase date is based on your original
sales receipt.
APC8200 Instrucons revised - February 16, 2017 11:34 AM
WARRANTY
Like us on Facebook, follow us on Twier,
and check out Hydrofarmtv on YouTube and Instagram!
Get Connected with the Hydrofarm Community:
precise climate control
precise climate control
Other manuals for Autopilot APC8200
1
Table of contents
Other Hydrofarm Controllers manuals

Hydrofarm
Hydrofarm Xtrasun LT1 User manual

Hydrofarm
Hydrofarm Autopilot PX1 User manual

Hydrofarm
Hydrofarm Autopilot PX2 User manual

Hydrofarm
Hydrofarm autopilot ANALOG CO2 CONTROLLER User manual

Hydrofarm
Hydrofarm Deluxe CLIMATE User manual

Hydrofarm
Hydrofarm Active Aqua Grow Flow User manual

Hydrofarm
Hydrofarm Active Aqua Grow Flow User manual

Hydrofarm
Hydrofarm Autopilot APC8200 User manual

Hydrofarm
Hydrofarm Autopilot APCL4DX User manual

Hydrofarm
Hydrofarm Autopilot PX2 User manual