Congratulations on your purchase of a Hydrofarm Climate Controller. This device will help you
keep temperature and/or humidity at the desired levels for optimum plant growth. Please read
the following instructions carefully before using your controller.
INSTALLATION
Your Controller mounts to any surface or wall with ordinary wood or sheet metal screws (not
provided). Choose a location which is representative of the environmental conditions you want
to control. Usually a middle point in the growing area is a good spot.When you mount the unit,
mount it upright as shown in the illustration. Make sure the mounting screws you use go firmly
into the mounting surface. Long screws are recommended.
OPERATION
Your controller is designed to control temperature (Temperature Controller only) and/or humid-
ity (Deluxe Climate Controller). Following the instructions on page 2, connect the desired items
to the appropriate outlets.
NOTE: Setting humidity to 80% or higher may cause your exhaust fan to run
constantly. Setting your temperature/humidity to a lower mark than your exhaust
equipment will cause your exhaust system to operate constantly. In this situation
a larger fan or air conditioning unit may be needed. Consult your local Hydrofarm
retailer for recommendations.
© 2005 Hydrofarm Inc. Petaluma CA
CONTROLLER INSTRUCTIONS
CONTROLLER INSTRUCTIONS
controller instructions
controller instructions
1. POWER CORD
Plug into normal 120V outlet.Your controller is rated to oper-
ate up to 10 amps of equipment. (10 amps is recommended
maximum load for the 15 amp rated controller.) Make sure the
circuit is rated for 15 amps or more and does not have other
high wattage equipment on the same circuit.
2. CONTROL OUTLETS
Both of these outlets will be activated by either a rise in tem-
perature or humidity above the settings on the dials. Usually
exhaust, intake, and/or circulation fans are used to control
these environmental factors by increasing air flow. Air con-
ditioners or dehumidifiers could also be used. Do not exceed
recommended maximum of 10 amps.
3. CIRCULATION OUTLET
This outlet is ON whenever the control unit is plugged in.This
outlet would be used for oscillating fans (constant air circu-
lation), ionizers, air cleaners or other devices that would be
operated continuously.
4. INTERMITTENT EQUIPMENT OUTLET
This outlet is where your CO2system should be plugged
directly in if you want it to shut off upon activation by your
temperature or humidity rise. This will prevent wasting CO2
while your exhaust fans are on.
When using a Hydrofarm CO2system, plug the timer upside
down into the intermittent equipment outlet and recalculate
your flowmeter setting following these steps:
1. Calculate the cubic feet of your growing area.
(Length x Width x Height = Cubic Feet)
2. Multiply Cubic Feet x .0012 to equal the amount
of CO2per hour for flow meter setting.
3. Set the flowmeter.
This is a higher setting than the CO2instructions calculate
because the CO2system timer allows for slow CO2build
up. With the Deluxe Climate Controller in use, the CO2
enhancement will be constant unless stopped by tempera-
ture or humidity rise. The garden will need to be replen-
ished rapidly for optimum growth, thus the higher setting.
CO2 TIMER SETTING
To stop CO2flow during dark cycle, the CO2timer should be
reset to go on and off with the lights. Manual timers may peri-
odically need to be adjusted to compensate for the “off” time
when your fans are on. Digital timers with a battery back-up
will hold the correct time even though the power is shut off
to the timer when the fans are on. A digital timer upgrade is
available from your Hydrofarm dealer.
THERMOSTAT CALIBRATION
Place a thermometer next to the controller. Allow it to stabi-
lize for an hour.Turn the temperature control knob slowly to
match the thermometer setting. Using a small screwdriver,
gently turn the calibration screw (in the hole below the
temperature control knob) until a click is heard. This screw
is typically tight from the factory, so use caution with firm
pressure when turning. It is now calibrated. The humidity
controller is factory calibrated and won't need adjustment.
©2005 Hydrofarm Inc.
rev. 4/05
OTHER FINE PRODUCTS FROM HYDROFARM
- Hydrofarm High Intensity Grow Lights
- Light Track™ Systems
- Hydrofarm CO2Systems
GUARANTEE
All our controls are guaranteed to the original owner for one year from the date
of purchase. Save your receipt/invoice — a copy is required for all warranty work.
Misuse, abuse, or failure to follow instructions are not covered. If you have a
problem, recheck your system to isolate the problem. If this doesn’t remedy the
situation, call the place of purchase to get a Return Authorization for the faulty
part. Send only that part. Unauthorized returns will not be accepted.
ON
OFF
20
30
4 0
50
60
70
80
Daystar™Reflector
Light Track™

Other Hydrofarm Controllers manuals

Hydrofarm Active Aqua Grow Flow User manual

Hydrofarm

Hydrofarm Active Aqua Grow Flow User manual

Hydrofarm Autopilot PX2 User manual

Hydrofarm

Hydrofarm Autopilot PX2 User manual

Hydrofarm APCETHD User manual

Hydrofarm

Hydrofarm APCETHD User manual

Hydrofarm Xtrasun LT1 User manual

Hydrofarm

Hydrofarm Xtrasun LT1 User manual

Hydrofarm Active Aqua Grow Flow User manual

Hydrofarm

Hydrofarm Active Aqua Grow Flow User manual

Hydrofarm autopilot APC8400 User manual

Hydrofarm

Hydrofarm autopilot APC8400 User manual

Hydrofarm autopilot APCETHA User manual

Hydrofarm

Hydrofarm autopilot APCETHA User manual

Hydrofarm Autopilot PX2 User manual

Hydrofarm

Hydrofarm Autopilot PX2 User manual

Hydrofarm autopilot ANALOG CO2 CONTROLLER User manual

Hydrofarm

Hydrofarm autopilot ANALOG CO2 CONTROLLER User manual

Hydrofarm Autopilot PX1 User manual

Hydrofarm

Hydrofarm Autopilot PX1 User manual

Hydrofarm Autopilot APCL4DX User manual

Hydrofarm

Hydrofarm Autopilot APCL4DX User manual

Hydrofarm Autopilot APC8200 User manual

Hydrofarm

Hydrofarm Autopilot APC8200 User manual

Hydrofarm Autopilot APC8200 User manual

Hydrofarm

Hydrofarm Autopilot APC8200 User manual

Hydrofarm Autopilot PX2 User manual

Hydrofarm

Hydrofarm Autopilot PX2 User manual

Hydrofarm Autopilot APCTART User manual

Hydrofarm

Hydrofarm Autopilot APCTART User manual

Popular Controllers manuals by other brands

Nitto Kohki delvo DLV45C Series user manual

Nitto Kohki

Nitto Kohki delvo DLV45C Series user manual

AWELCO THOR 750 manual

AWELCO

AWELCO THOR 750 manual

SLV 470810 Quick installation guide

SLV

SLV 470810 Quick installation guide

Savant LCB-DMX1 Deployment guide

Savant

Savant LCB-DMX1 Deployment guide

Elan Z-600 owner's manual

Elan

Elan Z-600 owner's manual

Dontek AQUATEK instruction manual

Dontek

Dontek AQUATEK instruction manual

Oldham MX 43 user manual

Oldham

Oldham MX 43 user manual

ST STEVAL-A6983NV1 Getting started

ST

ST STEVAL-A6983NV1 Getting started

Extron electronics MLC 206 Backlight Replacement Guide

Extron electronics

Extron electronics MLC 206 Backlight Replacement Guide

Festo VPPM-6TA-L-1-F-0L10H Assembly instructions

Festo

Festo VPPM-6TA-L-1-F-0L10H Assembly instructions

SOMFY animeo IB+ 9001614 installation guide

SOMFY

SOMFY animeo IB+ 9001614 installation guide

Skov DOL 278AT user manual

Skov

Skov DOL 278AT user manual

BIFFI ALGAS-QA Series Instruction and operation manual

BIFFI

BIFFI ALGAS-QA Series Instruction and operation manual

Omron YSC-8361 instruction manual

Omron

Omron YSC-8361 instruction manual

Geco GH11NB user manual

Geco

Geco GH11NB user manual

Honeywell Home TheraPro HR90 owner's guide

Honeywell Home

Honeywell Home TheraPro HR90 owner's guide

ESP Safety UPES-50D operating manual

ESP Safety

ESP Safety UPES-50D operating manual

Inocybe Opendaylight user guide

Inocybe

Inocybe Opendaylight user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.