IDS X64 Operating instructions


IDS X64 Quick Programming Guide 700-398-03A Issued August 2010
2

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010
3
LOCATION 0
Defaulting the Panel or Master User Code
[#] [INSTALLER CODE] [*] [0] [*] [VALUE] [*]
Value
Action
0
Will reset all locations to the factory default values.
(Master User Code 1234) and all keypad IDs will be defaulted.
1
Will default the master user code to 1234 - or 123456 if 6 digits are being used.
Master user code properties will also be defaulted.
2
Defaults ALL user codes and their properties.
3
Defaults ALL keypads
4
Remove Missing Devices
Any missing devices (keypads, for example), will have its address freed up, making its address
available for a new device when it is enrolled. This MUST be performed when replacing a faulty
device. (You must wait for 10 seconds.)

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010
4
LOCATIONS 1 - 8
Individual Zone Type Setup (Zones 1 –64)
[#] [INSTALLER CODE] [*] [LOCATION] [*] [ZONE NUMBER] [*] [ZONE TYPE] [*]
Location = 1 –8
Zone number = 1 –64
Value
Zone Type
00
DISABLED
A zone violation of a Disabled zone is ignored by the control panel and will not be indicated on the
keypad.
01
PRIMARY ENTRY / EXIT ZONE
Violations of an Entry/Exit zone are ignored during the exit delay period of the arming procedure.
Violating an Entry/Exit zone when armed will initiate the entry delay. If a valid User Code is not entered
before the entry delay period expires, an alarm condition will be registered. Failure to exit through an
Entry/Exit zone after arming will cause the panel to Stay Arm.
This zone may also function as an Entry/Exit zone that is COMMON to two partitions. In such a case,
should a user violate this zone and then disarm his partition, the OTHER partition will re-arm after the
entry delay.
02
FOLLOWER ZONE
A violation of a Follower zone is ignored during the Entry/Exit delay period (this allows the user to
enter/exit via the Follower zone). A Follower zone will behave as an Instant zone if the panel is armed
and an Entry/Exit zone is not violated prior to violation of the Follower zone.
03
PANIC / PRIORITY ZONE
Regardless of whether the panel is armed or not, a violation of a Priority zone will cause the control
panel to register a panic condition. This zone type CANNOT be bypassed.
04
INSTANT ZONE
When the panel is armed the violation of an Instant zone will cause the control panel to register an
alarm condition.
05
ARM / DISARM ZONE
The violation of an Arm/Disarm zone will cause the panel to toggle between (away) armed and
disarmed. It is typical to connect a momentary key-switch, or non-latching remote control unit to this
zone.
08
SECONDARY ENTRY / EXIT ZONE
The Secondary Entry delay will be activated if this zone is violated when the panel is armed.
10
FIRE ZONE
Violation of a Fire Zone will cause the siren to sound regardless of whether the panel is armed or not.
The siren will sound intermittently (one second on, one second off). For correct operation, a
programmable output programmed as a fire detector power output must be used to control power to
the fire detector.
11
TAMPER ZONE
Violation of this zone will be reported to the base station regardless of whether the panel is armed or
disarmed. If the panel is armed, the siren will be activated.
12
24 HOUR ALARM ZONE
This works the same as a Panic zone –with the exception that it is able to be bypassed.
13
WARNING ZONE
When the panel is armed, violation of a Warning zone will cause the siren to beep. The violation is
logged in the event log but it is not reported to the base station. Warning zones may be included and
will be counted when used as part of the cross-zone
14
PUSH TO ARM ZONE
Violation
of
a
Push
to
A
rm
zone
during
the
exit
delay
will immediately
arm
the
panel.
15
OUTDOOR INSTANT ZONE
When the panel is armed the violation of an Outdoor Instant zone will cause the panel to register an
alarm condition.

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010
5
LOCATION 10
Zone Shutdown Count (default = 5)
[#] [INSTALLER CODE] [*] [1] [0] [*] [ZONE SHUTDOWN COUNT] [*]
Zone shutdown count = 1 –15
LOCATION 11
Programmable Zone Loop Response Time (default = 2)
[#] [INSTALLER CODE] [*] [1] [1] [*] [ZONE LOOP RESPONSE TIME] [*]
Zone loop response time = 1 –255
LOCATION 12
Cross-zone Delay Time (default = 0030)
[#] [INSTALLER CODE] [*] [1] [2] [*] [MMSS] [*]
MMSS = 00m00s –59m59s
LOCATION 13
Cross-zone Count (default = 3)
[#] [INSTALLER CODE] [*] [1] [3] [*] [CROSS-ZONE COUNT] [*]
Cross zone count = 1 –15, with 0 to disable

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010
6
LOCATION 14
Global Options
[#] [INSTALLER CODE] [*] [1] [4] [*] [BITMAP] [*]
LED
On / Off
Action
1
ON
A user assigned to any partition may cancel the siren
OFF
Only a user assigned to the partition that triggered the siren may cancel the siren
2
ON
Enable keypad trouble beep
OFF
Disable keypad trouble beep
3
ON
Enable telephone line monitoring
OFF
Disable telephone line monitoring
4
ON
Enable keypad beep on successful reporting to the base station
OFF
Disable keypad beep on successful reporting to the base station
5
ON
Enable keypad Fire, Medical and Panic keys
OFF
Disable keypad Fire, Medical and Panic keys
6
ON
Enable the display of bypassed and stay zones when armed
OFF
Disable the display of bypassed and stay zones when armed
7
ON
Enable the siren delay
OFF
Disable the siren delay
8
ON
Enable box tamper monitoring
OFF
Disable box tamper monitoring
9
ON
Enable siren monitoring
OFF
Disable siren monitoring
10
ON
Enable bus-wired peripheral tamper monitoring*
OFF
Disable bus-wired peripheral tamper monitoring*
11
ON
Enable onboard dedicated panic –silent
OFF
Disable onboard dedicated panic–audible
12
ON
Enable low battery monitoring**
OFF
Disable low battery monitoring**
13
ON
Enable low battery cut-out**
OFF
Disable low battery cut-out**
Default values are shaded
*Option 9 in location 16 must be enabled for this to work.
** Option 12 needs to be enabled in order for option 13 to work.
LOCATION 15
AC Fail / Restore Reporting Delay (default = 0004)
[#] [INSTALLER CODE] [*] [1] [5] [*] [HHMM] [*]
HHMM = 00h01m –18h00m

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010
7
LOCATION 16
Trouble Display Enable
[#] [INSTALLER CODE] [*] [1] [6] [*] [BITMAP] [*]
LED
On /
Off
Action
1
ON
Enable
AC
fail
trouble
display
OFF
Disable
AC
fail
trouble
display
2
ON
Enable
reporting
communications
fail
trouble
display
OFF
Disable
reporting c
ommunications
fail
trouble
display
3
ON
Enable
tele
phone
line
monitoring
trouble
display
OFF
Disable
tele
phone monitoring
line
trouble
display
4
ON
Enable
siren
monitoring
trouble
display
OFF
Disable
siren
monitoring
trouble
display
5
ON
Enable
low
battery
monitoring
trouble
display
OFF
Disable
low
battery
monitoring
trouble
display
6
ON
Enable
Aux.
12V
monitoring
trouble
display
OFF
Disable
Aux.
12V
monitoring
trouble
display
7
ON
Enable
engineer's
reset
trouble
display
OFF
Disable
engineer’s
reset
trouble
display
8
ON
Enable
box
tamper
trouble
display
OFF
Disable
box
tamper
trouble
display
9
ON
Enable bus-wired peripheral tamper trouble display
OFF
Disable bus-wired peripheral tamper trouble display
10
ON
Enable
bus-wired peripheral fail
trouble
display
OFF
Disable
bus-wired peripheral fail
trouble
display
11
ON
Enable
bus-wired peripheral low power/ battery trouble
display
OFF
Disable bus-wired
peripheral low power/ battery trouble
display
12
ON
Enable EEPROM trouble display
OFF
Disable EEPROM trouble display
Default values are shaded
LOCATION 17
Siren Time Out Period (default = 0200)
[#] [INSTALLER CODE] [*] [1] [7] [*] [MMSS] [*]
MMSS = 00m01s –59m59s
LOCATION 18
Siren Delay (default = 0200)
[#] [INSTALLER CODE] [*] [1] [8] [*] [MMSS] [*]
MMSS = 00m01s –59m59s
LOCATION 20
Keypad Lockout Count (default = 4)
[#] [INSTALLER CODE] [*] [2] [0] [*] [KEYPAD LOCKOUT COUNT] [*]
Lockout count = 2 –16

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010
8
LOCATION 21
Keypad Lockout Time (default = 0030)
[#] [INSTALLER CODE] [*] [2] [1] [*] [MMSS] [*]
MMSS = 00m01s –59m59s
LOCATION 22
Keypad Sleep Delay (default = 0500)
[#] [INSTALLER CODE] [*] [2] [2] [*] [MMSS] [*]
MMSS = 00m01s –59m59s
LOCATION 23
User, Installer & Maintenance Code - Number of Digits (default = 4)
[#] [INSTALLER CODE] [*] [2] [3] [*] [NUMBER OF DIGITS] [*]
Number of digits = 4 or 6
LOCATION 24
Number of Account Code Digits (default = 4)
[#] [INSTALLER CODE] [*] [2] [4] [*] [NUMBER OF DIGITS] [*]
Number of digits = 4 or 6
LOCATION 25
Month to Start Daylight Saving (default = 1)
[#] [INSTALLER CODE] [*] [2] [5] [*] [MONTH] [*]
Month = 1 –12, with 0 to disable
LOCATION 26
Day of Week to Start Daylight Saving (default = 1)
[#] [INSTALLER CODE] [*] [2] [6] [*] [DAY] [*]
Day = 1 –7
LOCATION 27
Week of Month to Start Daylight Saving (default = 1)
[#] [INSTALLER CODE] [*] [2] [7] [*] [WEEK] [*]
Week = 1 –5
LOCATION 28
Month to End Daylight Saving (default = 1)
[#] [INSTALLER CODE] [*] [2] [8] [*] [MONTH] [*]
Month = 1 –12, with 0 to disable
LOCATION 29
Day of Week to End Daylight Saving (default = 1)
[#] [INSTALLER CODE] [*] [2] [9] [*] [DAY] [*]
Day = 1 –7

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010
9
LOCATION 30
Week of Month to End Daylight Saving (default = 1)
[#] [INSTALLER CODE] [*] [3] [0] [*] [WEEK] [*]
Week = 1 –5
LOCATION 31
Daylight Saving Time Offset (default = 60)
[#] [INSTALLER CODE] [*] [3] [1] [*] [DAYLIGHT SAVING TIME OFFSET] [*]
Daylight saving time = 0 –250
LOCATION 32
Auto Test Report Interval (default = 1)
[#] [INSTALLER CODE] [*] [3] [2] [*] [AUTO TEST REPORT INTERVAL] [*]
Auto test interval = 0 –15
LOCATION 33
Auto Test Time (default = 0010)
[#] [INSTALLER CODE] [*] [3] [3] [*] [HHMM] [*]
HHMM = 00h00m –23h59m
LOCATION 34
Download Code Default Disable (default = 0)
[#] [INSTALLER CODE] [*] [3] [4] [*] [DOWNLOAD CODE DEFAULT DISABLE] [*]
Download code default disable = 0 or 10
LOCATION 35
Hardware Default Switch Disable (default = 0)
[#] [INSTALLER CODE] [*] [3] [5] [*] [HARDWARE DEFAULT SWITCH DISABLE] [*]
Reset switch disable = 0 or 10
LOCATION 41
Telephone Number 1 Communications Format (default = 5)
[#] [INSTALLER CODE] [*] [4] [1] [*] [TELEPHONE NO. 1 COMMUNICATIONS FORMAT] [*]
Value
Format Name
Description
0
Ademco Express
Dual Tone HS, DTMF
1
FBI 4 x 2 ( With Parity)
1.8kHz TX, 2.3kHz HS, 40PPS
2
FBI 4 x 2 (No Parity)
1.8kHz TX, 2.3kHz HS, 20PPS
3
Silent Knight 4 x 2 Fast
1.9kHz TX, 1.4kHz, 20PPS
4
Silent Knight 4 x 2 Slow
1.9kHz TX, 1.4kHz, 20PPS
5
Contact ID
Dual Tone HS, DTMF
6
Reserved
7
SIA Reporting
1170Hz TX, Blind 20PPS
8
Reserved
Telephone No. 1 Communications Format = 0 –8

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010
10
LOCATION 42
Telephone Number 2 Communications Format (default = 5)
[#] [INSTALLER CODE] [*] [4] [2] [*] [TELEPHONE NO. 2 COMMUNICATIONS FORMAT] [*]
Telephone No.2 Communications Format = 0 –8
LOCATION 43
Telephone Number 3 Communications Format (default = 5)
[#] [INSTALLER CODE] [*] [4] [3] [*] [TELEPHONE NO. 3 COMMUNICATIONS FORMAT] [*]
Telephone No. 3 Communications Format = 0 –8
LOCATION 44
Telephone Number 4 Communications Format (default = 5)
[#] [INSTALLER CODE] [*] [4] [4] [*] [TELEPHONE NO. 4 COMMUNICATIONS FORMAT] [*]
Telephone No. 4 Communications Format = 0 –8
LOCATION 45
Communication Delay (default = 0020)
[#] [INSTALLER CODE] [*] [4] [5] [*] [MMSS] [*]
MMSS = 00m01s –59m59s
LOCATION 46
Reporting Communications Options
[#] [INSTALLER CODE] [*] [4] [6] [*] [BITMAP] [*]
LED
On / Off
Action
1
ON
Tone Dialling Enabled
OFF
Pulse Dialling Enabled
2
ON
Join the telephone numbers together
OFF
Keep two separate telephone numbers
3
ON
Enable Dual Reporting
OFF
Disable Dual Reporting
Default values are shaded
LOCATION 47
Number of Dial Attempts (default = 6)
[#] [INSTALLER CODE] [*] [4] [7] [*] [NUMBER OF DIAL ATTEMPTS] [*]
Number of dial attempts = 1 –9, with 0 to disable

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010
11
LOCATION 48
Download Options
[#] [INSTALLER CODE] [*] [4] [8] [*] [BITMAP] [*]
LED
On / Off
Action
1
ON
Enable Fax Defeat
OFF
Disable Fax Defeat
2
ON
Enable Forced Answer
OFF
Disable Forced Answer
3
ON
Enable Auto Pickup
OFF
Disable Auto Pickup
4
ON
Enable Call-back
OFF
Disable Call-back
Default values are shaded
LOCATION 49
Number of Rings to Answer (default = 15)
[#] [INSTALLER CODE] [*] [4] [9] [*] [NUMBER OF RINGS TO ANSWER] [*]
Number of rings to answer = 1 –15
LOCATION 50
Call-back Telephone Number
[#] [INSTALLER CODE] [*] [5] [0] [*] [CALL-BACK NUMBER] [*]
Call-back number = a maximum of 24-digits
LOCATION 51
Telephone Number 1
[#] [INSTALLER CODE] [*] [5] [1] [*] [TELEPHONE NUMBER 1] [*]
Phone number 1 = a maximum of 24-digits
LOCATION 52
Telephone Number 2
[#] [INSTALLER CODE] [*] [5] [2] [*] [TELEPHONE NUMBER 2] [*]
Phone number 2 = a maximum of 24-digits
LOCATION 53
Telephone Number 3
[#] [INSTALLER CODE] [*] [5] [3] [*] [TELEPHONE NUMBER 3] [*]
Phone number 3 = a maximum of 24-digits
LOCATION 54
Telephone Number 4
[#] [INSTALLER CODE] [*] [5] [4] [*] [TELEPHONE NUMBER 1] [*]
Phone number 4 = a maximum of 24-digits

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010
12
LOCATIONS 61-68
Primary Account Codes (Partitions 1- 8)
[#] [INSTALLER CODE] [*] [LOCATION] [*] [PRIMARY ACCOUNT CODE] [*]
Location = 61 –68
LOCATIONS 71-78
Secondary Account Codes (Partitions 1- 8)
[#] [INSTALLER CODE] [*] [LOCATION] [*] [SECONDARY ACCOUNT CODE] [*]
Location = 71 –78
LOCATIONS 101-164
Zone Type Properties (Zones 1 –64)
[#] [INSTALLER CODE] [*] [LOCATION] [*] [BITMAP] [*]
Location = 101 –164
LED
ON / OFF
Zone Properties
LED
ON / OFF
Zone Properties
1
ON
Tamper by Zone Enabled
9
ON
Stay Profile 1
OFF
Tamper by Zone Disabled
OFF
2
ON
Cross-zone Enabled
10
ON
Stay Profile 2
OFF
Cross-zone Disabled
OFF
3
ON
Shutdown Zone Enabled
11
ON
Stay Profile 3
OFF
Shutdown Zone Disabled
OFF
4
ON
Silent Zone Enabled
12
ON
Stay Profile 4
OFF
Silent Zone Disabled
OFF
5
ON
Chime Zone Enabled
13
ON
Buzz Profile 1
OFF
Chime Zone Disabled
OFF
6
14
ON
Buzz Profile 2
OFF
7
15
ON
Buzz Profile 3
OFF
8
16
ON
Buzz Profile 4
OFF
Default values are shaded
LOCATION 171
No Movement Auto Arm Time Out (default = 00)
[#] [INSTALLER CODE] [*] [1] [7] [1] [*] [PARTITION NUMBER] [*] [AUTO ARM TIME OUT] [*]
Partition number = 1 –8
Auto arm time out = 01 –23, with 00 to disable
LOCATION 172
No Movement Auto Arm Start (default = 0000)
[#] [INSTALLER CODE] [*] [1] [7] [2] [*] [PARTITION NUMBER] [*] [HHMM] [*]
Partition number = 1 –8
HHMM = 00h00m –23h59m,

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010
13
LOCATION 173
No Movement Auto Arm End (default = 2400)
[#] [INSTALLER CODE] [*] [1] [7] [3] [*] [PARTITION NUMBER] [*] [HHMM] [*]
Partition number = 1 –8
HHMM = 00h00m –23h59m
LOCATION 174
No Movement Medical Alarm (default = 00)
[#] [INSTALLER CODE] [*] [1] [7] [4] [*] [PARTITION NUMBER] [*] [ALARM TIME OUT] [*]
Partition number = 1 –8
Alarm arm time out = 01 –23, with 00 to disable
LOCATION 175
No Movement Medical Alarm Start (default = 0100)
[#] [INSTALLER CODE] [*] [1] [7] [5] [*] [PARTITION NUMBER] [*] [HHMM] [*]
Partition number = 1 –8
HHMM = 00h00m –23h59m
LOCATION 176
No Movement Alarm End (default = 0100)
[#] [INSTALLER CODE] [*] [1] [7] [6] [*] [PARTITION NUMBER] [*] [HHMM] [*]
Partition number = 1 –8
HHMM = 00h00m –23h59m
LOCATION 180
Auto Arm Time (default = 2400)
[#] [INSTALLER CODE] [*] [1] [8] [0] [*] [PARTITION NUMBER] [*] [HHMM] [*]
Partition number = 1 –8
HHMM = 00h00m –23h59m, with 24h00m to disable
LOCATIONS 181 - 188
Auto Arm/Disarm Days (default = all OFF)
[#] [INSTALLER CODE] [*] [LOCATION] [*] [BITMAP] [*]
Location = 181 - 188
LED
ARM Days of the Week
LED
DISARM Days of the Week
1
Monday
9
Monday
2
Tuesday
10
Tuesday
3
Wednesday
11
Wednesday
4
Thursday
12
Thursday
5
Friday
13
Friday
6
Saturday
14
Saturday
7
Sunday
15
Sunday
All OFF
(Arm Day Disabled)
All OFF
(Disarm Day Disabled)

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010
14
LOCATION 189
Auto Disarm Time (default = 2400)
[#] [INSTALLER CODE] [*] [1] [8] [9] [*] [PARTITION NUMBER] [*] [HHMM] [*]
Partition number = 1 –8
HHMM = 00h00m –23h59m, with 24h00m to disable
LOCATION 190
Auto Arm Delay (default = 0200 i.e. 2 minutes)
[#] [INSTALLER CODE] [*] [1] [9] [0] [*] [PARTITION NUMBER] [*] [MMSS] [*]
Partition number = 1 –8
MMSS = 00m01s –59m59s
LOCATION 197
Installers Code (default = 9999)
[#] [INSTALLER CODE] [*] [1] [9] [7] [*] [NEW INSTALLER CODE] [*]
LOCATION 198
Download Code (default = 9999)
[#] [INSTALLER CODE] [*] [1] [9] [8] [*] [NEW DOWNLOAD CODE] [*]
LOCATION 199
Maintenance Code (default = 8888)
[#] [INSTALLER CODE] [*] [1] [9] [9] [*] [NEW MAINTENACE CODE] [*]
LOCATIONS 201 - 208
Partition Zone Allocation
[#] [INSTALLER CODE] [*] [LOCATION] [*] [BITMAP] [*]
Location = 201 –208
Page
1
2
3
4
LED Indicator
READY
ARMED
AWAY
POWER
Zones
1
9
2
10
3
11
4
12
5
13
6
14
7
15
8
16
17
25
18
26
19
27
20
28
21
29
22
30
23
31
24
32
33
41
34
42
35
43
36
44
37
45
38
46
39
47
40
48
49
57
50
58
51
59
52
60
53
61
54
62
55
63
56
64
LOCATIONS 211 - 218
Partition Arm Options (Partitions 1 –8)
[#] [INSTALLER CODE] [*] [LOCATION] [*] [BITMAP] [*]
Location = 211 –218

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010
15
LED
On / Off
Action
1
ON
Enable Instant Arm
OFF
Disable Instant Arm
2
ON
Enable Instant Key-switch Arm
OFF
Disable Instant Key-switch Arm
3
ON
Enable Quick Arm Key
OFF
Disable Quick Arm Key
4
ON
Enable Quick Stay Arm Key
OFF
Disable Quick Stay Arm Key
5
ON
Enable Auto Stay Arm if No Exit Zone is Triggered*
OFF
Panel Away Arms Regardless of Zone Triggered*
6
ON
Enable Auto Stay Arm if No Exit Zone is Triggered When Arming with a Key-
switch*
OFF
Disable Auto Stay Arm if No Exit Zone is Triggered When Arming with a
Key-switch *
7
ON
Enable Forced Arm
OFF
Disable Forced Arm
8
ON
Enable Zone Bypassing
OFF
Disable Zone Bypassing
9
ON
Enable Arm with Zones in the Entry Route Violated
OFF
Disable Arm with Zones in the Entry Route Violated
10
ON
Enable Siren Toot on Arm
OFF
Disable Siren Toot on Arm
11
ON
Enable Siren Toot on Disarm
OFF
Disable Siren Toot on Disarm
12
ON
Enable the Entry Beep
OFF
Disable the Entry Beep
13
ON
Enable the Exit Beep
OFF
Disable the Exit Beep
14
ON
Enable Engineer's Reset
OFF
Disable Engineer's Reset
15
ON
Enable Auto Disarm
OFF
Disable Auto Disarm
Default values are shaded
* For option 5 or 6 to work, option 2 needs to be disabled.
LOCATIONS 221 - 228
Extra Partition Options (Partitions 1 - 8)
[#] [INSTALLER CODE] [*] [LOCATION] [*] [BITMAP] [*]
Location = 221 –228

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010
16
LED
On/ Off
Action
1
ON
Enable Automatic Re-enabling of Shutdown Zones at the Time of the Dialler test
OFF
Disable Automatic Re-enabling of Shutdown Zones at the Time of the Dialler test
2
ON
Enable Bypassing of Common Zones
OFF
Disable Bypassing of Common Zones
3
ON
Enable Delay Before Communications
OFF
Disable Delay Before Communications
4
ON
Enable Keypad Lockout
OFF
Disable Keypad Lockout
5
ON
Enable Silent Keypad Panic
OFF
Disable Silent Keypad Panic
Default values are shaded
LOCATION 230
Exit Delay Period (default = 0030 i.e. 30 seconds)
[#] [INSTALLER CODE] [*] [2] [3] [0] [*] [PARTITION NUMBER] [*] [MMSS] [*]
Partition number = 1 –8
MMSS = 00m00s –59m59s
LOCATION 231
Primary Entry Delay Period (default = 0030 i.e. 30 seconds)
[#] [INSTALLER CODE] [*] [2] [3] [1] [*] [PARTITION NUMBER] [*] [MMSS] [*]
Partition number = 1 –8
MMSS = 00m00s –59m59s
LOCATION 232
Secondary Entry Delay Period (default = 0030 i.e. 30 seconds)
[#] [INSTALLER CODE] [*] [2] [3] [2] [*] [PARTITION NUMBER] [*] [MMSS] [*]
Partition number = 1 –8
MMSS = 00m00s –59m59s
LOCATION 240
Keypad Partition (default = Partition 1)
[#] [INSTALLER CODE] [*] [2] [4] [0] [*] [KEYPAD NUMBER] [*] [PARTITION NUMBER] [*]
Keypad number = 1 –8
Partition number = 1 –8
LOCATION 241
Keypad Display Start Zone (default = Zone 1)
[#] [INSTALLER CODE] [*] [2] [4] [1] [*] [KEYPAD NUMBER] [*] [START ZONE] [*]
Keypad number = 1 –8
Start zone = 01 –64

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010
17
LOCATION 242
Keypad Zone Number (default = 0, i.e. Disabled)
[#] [INSTALLER CODE] [*] [2] [4] [2] [*] [KEYPAD NUMBER] [*] [ZONE NUMBER] [*]
Keypad number = 1 –8
Start zone = 01 –64
LOCATION 243
View Keypad ID
[#] [INSTALLER CODE] [*] [2] [4] [3] [*]
LOCATIONS 251 - 258
Keypad Options
[#] [INSTALLER CODE] [*] [LOCATION] [*] [BITMAP] [*]
Location = 251 –258
LED
On / Off
Action
1
ON
The keypad will timeout back to its default partition after it has been used to
view another partition
OFF
The keypad will not timeout and will continue to show current partition
information
2
ON
Keypad sleep mode enabled
OFF
Keypad sleep mode disabled
3
ON
Enable Global Keypad Status
OFF
Disable Global Keypad Status
Default values are shaded
LOCATION 300
Global Reporting Code 1
[#] [INSTALLER CODE] [*] [3] [0] [0] [*] [SUB-LOCATION] [*] [REPORTING CODE] [*]
Sub-location = 1 –8
Sub-location 1 is AC Fail
Sub-location 2 is AC Restore
Sub-location 3 is Low Battery Monitor Fail
Sub-location 4 is Low Battery Monitor Restore
Sub-location 5 is Auto Test
Sub-location 6 is Download
Sub-location 7 is Siren Monitor Fail
Sub-location 8 is Aux 12V Monitor Fail
Reporting code = 01 –FF, with 00 to disable
LOCATION 301
Global Reporting Code 2
[#] [INSTALLER CODE] [*] [3] [0] [1] [*] [SUB-LOCATION] [*] [REPORTING CODE] [*]
Sub-location = 1 –8
Sub-location 1 is Reserved
Sub-location 2 is Bus-wired Peripheral Tamper

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010
18
Sub-location 3 is Bus-wired Peripheral Fail
Sub-location 4 is Box Tamper
Sub-location 5 is Dedicated Panic
Sub-location 6 is Reserved
Sub-location 7 is Telephone Line Tamper
Sub-location 8 is Telephone Line Restore
Reporting code = 01 –FF, with 00 to disable
LOCATION 303
Global Reporting Code 4
[#] [INSTALLER CODE] [*] [3] [0] [3] [*] [SUB-LOCATION] [*] [REPORTING CODE] [*]
Sub-location = 1 –8
Sub-location 1 is Wired Zone Expander Low Power Supply Monitoring
Sub-location 2 is Wired Zone Expander Low Power Supply Restore
Sub-location 3 is Reserved
Sub-location 4 is Reserved
Sub-location 5 is Reserved
Sub-location 6 is Reserved
Sub-location 7 is Reserved
Sub-location 8 is Reserved
Reporting code = 01 –FF, with 00 to disable
LOCATIONS 304 - 307
Zone Alarm Reporting Code
[#] [INSTALLER CODE] [*] [LOCATION] [*] [ZONE NUMBER] [*] [REPORTING CODE] [*]
Location = 304 –307
Zone Number = 01 –64
Reporting code = 01 –FF, with 00 to disable
LOCATIONS 308 - 311
Zone Alarm Restoral Reporting Code
[#] [INSTALLER CODE] [*] [LOCATION] [*] [ZONE NUMBER] [*] [REPORTING CODE] [*]
Location = 308 –311
Zone Number = 01 –64
Reporting code = 01 –FF, with 00 to disable
LOCATIONS 312 - 315
Zone Tamper Reporting Code
[#] [INSTALLER CODE] [*] [LOCATION] [*] [ZONE NUMBER] [*] [REPORTING CODE] [*]
Location = 312 –315
Zone Number = 01 –64
Reporting code = 01 –FF, with 00 to disable
LOCATIONS 316 - 319
Zone Tamper Restore Reporting Code
[#] [INSTALLER CODE] [*] [LOCATION] [*] [ZONE NUMBER] [*] [REPORTING CODE] [*]
Location = 316 –319
Zone Number = 01 –64

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010
19
Reporting code = 01 –FF, with 00 to disable
LOCATIONS 320 - 323
Zone Bypass Reporting Code
[#] [INSTALLER CODE] [*] [LOCATION] [*] [ZONE NUMBER] [*] [REPORTING CODE] [*]
Location = 320 –323
Zone Number = 01 –64
Reporting code = 01 –FF, with 00 to disable
LOCATIONS 324 - 327
Zone Force Arm Reporting Code
[#] [INSTALLER CODE] [*] [LOCATION] [*] [ZONE NUMBER] [*] [REPORTING CODE] [*]
Location = 324 –327
Zone Number = 01 –64
Reporting code = 01 –FF, with 00 to disable
LOCATIONS 328 - 331
Zone Swinger Shutdown Reporting Code
[#] [INSTALLER CODE] [*] [LOCATION] [*] [ZONE NUMBER] [*] [REPORTING CODE] [*]
Location = 328 –331
Zone Number = 01 –64
Reporting code = 01 –FF, with 00 to disable
LOCATIONS 332 - 335
Zone Swinger Shutdown Restore Reporting Code
[#] [INSTALLER CODE] [*] [LOCATION] [*] [ZONE NUMBER] [*] [REPORTING CODE] [*]
Location = 3332 –335
Zone Number = 01 –64
Reporting code = 01 –FF, with 00 to disable
LOCATION 336
Duress Reporting Code
[#] [INSTALLER CODE] [*] [3] [3] [6] [*] [PARTITION] [*] [REPORTING CODE] [*]
Partition = 1 –8
Reporting code = 01 –FF, with 00 to disable
LOCATION 337
Keypad Panic Reporting Code
[#] [INSTALLER CODE] [*] [3] [3] [7] [*] [PARTITION] [*] [REPORTING CODE] [*]
Partition = 1 –8
Reporting code = 01 –FF, with 00 to disable
LOCATION 338
Keypad Fire Reporting Code
[#] [INSTALLER CODE] [*] [3] [3] [8] [*] [PARTITION] [*] [REPORTING CODE] [*]
Partition = 1 –8

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010
20
Reporting code = 01 –FF, with 00 to disable
LOCATION 339
Keypad Medical Reporting Code
[#] [INSTALLER CODE] [*] [3] [3] [9] [*] [PARTITION] [*] [REPORTING CODE] [*]
Partition = 1 –8
Reporting code = 01 –FF, with 00 to disable
LOCATION 340
Keypad Lockout Reporting Code
[#] [INSTALLER CODE] [*] [3] [4] [0] [*] [PARTITION] [*] [REPORTING CODE] [*]
Partition = 1 –8
Reporting code = 01 –FF, with 00 to disable
LOCATIONS 342 - 349
Close Reporting Code
[#] [INSTALLER CODE] [*] [LOCATION] [*] [USER] [*] [REPORTING CODE] [*]
Location = 342 –349
User = 01 –128
Reporting code = 01 –FF, with 00 to disable
LOCATIONS 350 - 357
Stay Close Reporting Code
[#] [INSTALLER CODE] [*] [LOCATION] [*] [USER] [*] [REPORTING CODE] [*]
Location = 350 –357
User = 01 –128
Reporting code = 01 –FF, with 00 to disable
LOCATIONS 358 - 365
Open Reporting Code
[#] [INSTALLER CODE] [*] [LOCATION] [*] [USER] [*] [REPORTING CODE] [*]
Location = 358 –365
User = 01 –128
Reporting code = 01 –FF, with 00 to disable
LOCATIONS 366 - 373
Siren Cancel Reporting Code
[#] [INSTALLER CODE] [*] [LOCATION] [*] [USER] [*] [REPORTING CODE] [*]
Location = 366 –373
User = 01 –128
Reporting code = 01 –FF, with 00 to disable