iNels Elko AirSF-100S User manual

1 / 3
ON
1 2 3
+
-
AirSF-100S
02-32/2019 Rev.: 2
4
2
5
3
1
6
ELKO EP, s.r.o.
Palackého 493
769 01 Holešov, Všetuly
Czech Republic
Tel.: +420 573 514 211
e-mail: [email protected]
www.elkoep.com
Characteristics
Description
EN
Flood detector
Made in Czech Republic
• The ood detector is used to detect water leakage - the activation occurs the mo-
ment the ooding of the contacts located on the underside of the detector occurs.
• Provides a quick solution to learn about unwanted ooding in your bathroom or
kitchen that you can react too immediately.
• With a wireless Sigfox communication network the device can be immediately put
in the desired location and run immediately.
• Flood detection is signalled by vibration, optical and acoustic signalling. In the case
of water detection, data is sent to the server, ...
• Data is sent to the server from which it can be subsequently displayed as a smart-
phone, application, or Cloud notication.
• Anti-sabotage: If access to the device is unauthorized, a message is immediately
sent to the server.
• Power supply: 1x CR123A battery.
1. Vibrating motor
2. Battery
3. DIP switch
4. Hooter
5. Antenna
6. Probes pads
Underside view
Cloud app assignment
It is done in your Smartphone application. Enter the relevant information on the product
cover into the application.
General instrucions
The front of the
detector
Seal
Function
The detector is designed to detect the presence of water in flooded areas such as cel-
lars, bathrooms, warehouses, etc. It is suitable for dealing with potentially recurring
situations such as bath overflow, washing machine, dishwasher, boiler, blockages or foul
waste, and floods due to groundwater, river or other emergencies.
Detector states
• Alarm - when the scanning contact is connected, the detector sends the data message
and starts the set alarm. The signalling type can be set by the DIP switch. Signalling
stops after 3 minutes even if the reason for the alarm has not been removed. In case of
positive detection, the audible alarm is restored after 5 minutes.
• Terminate the alarm after a few seconds after the flood has dropped (disconnect the
connection contacts).
• The data status report is sent at twelve-hour intervals (can be edited by a message
from the server). In case of detection 2 seconds after connection of sensing contacts.
Commissioning
• Remove the protective tape from the sensor contacts.
• To activate the detector, place a conductive object (such as the included paper clips) on
the sensing contacts. Hold for 20 seconds. The detector triggers a light and beep and
sends an initial message.
• CAUTION: The ood detector detects only the presence of liquid that has reached the
sensor. Liquid may be present in other areas.
• Always be aware of potential dangers, develop safety awareness, and take precautions
to avoid dangers whenever and wherever needed. The detector can reduce the likeli-
hood of catastrophe but cannot guarantee 100% safety.
Important Notice
Internet of Things (IoT)
• The IOT wireless communications category describes the Low Power Wide Area
(LPWA). This technology is designed to provide full-range coverage both inside and
outside buildings, energy-saving and low-cost operation of individual devices. The
Sigfox network is available to use this standard.
Sigfox network information
• The network supports bidirectional communication but with a limited number of feed-
backs. It uses the free frequency band divided by Radio Frequency Zones (RCZ).
• RCZ1 (868 MHz) Europe, Oman, South Africa
• RCZ2 (902 MHz) North America
• RCZ3 (923 MHz) Japan
• RCZ4 (920 MHz) South America, Australia, New Zealand, Singapore, Taiwan
• Sigfox has more coverage across countries, so it is better suited for long distance moni-
toring.
• For more information on this technology, please visit www.sigfox.com.
Caution for proper operation:
• Products are installed according to the wiring diagram given for each product.
• For proper device functionality, it is necessary to have sucient coverage of the se-
lected network at the installation site.
• At the same time, the device must be registered in the network. Successful device reg-
istration on a given network requires a charge for trac.
• Each network oers dierent tari options - it always depends on the number of mes-
sages you want to send from your device. Information on these taris can be found in
the current version of the ELKO EP pricelist.

2 / 3
7
1
+
-
5
+
-
6
+
-
2
ON
1 2 3
4
+
-
3
UPLINK
Byte 0 123
Bit7654321 0
NOTIFICATION
Reserved for future use
„Flood:
1 - alarm
0 - OK“
HEARTBEAT
START Version FW Subversion
FW
Version FW
Sigfox
Subversion
FW Sigfox
Replacement of a battery
1. Use a screwdriver to open the detector.
2. Remove the battery.
4. Use a metal object (such as a screwdriver) to connect the battery holders (to reset the
device). Caution - Do not touch other parts of the device with a metal object!
5. Insert the battery and check the correct location (when the battery is inserted, the
detector functionality message will be sent to the application).
6. Replace the seal, attach the front cover - make sure the correct location. Screw in,
tighten the screws to maintain IP protection.
7. Commissioning: To activate the detector, place a conductive object (such as the in-
cluded paper clips) on the sensing contacts. Hold for 20 seconds. The detector triggers
a light and beep and sends an initial message.
Notice:
Only use batteries designed for this product correctly inserted in the device! Immediately replace
weak batteries with new ones. Do not use new and used batteries together. If necessary, clean the
battery and contacts prior to using. Avoid battery shorts! Do not dispose of batteries in water or
re. Do not dismantle batteries, do not try to charge them and protect them from extreme heating
- danger of leakage! Upon contact with acid, immediately rinse the aected area with a stream of
water and seek medical attention. Keep batteries out of the reach of children. If it is suspected that
the battery has been swallowed or somehow placed inside the body, consult a doctor immediately.
Give the doctor information about the type of battery (from battery case, device or its manual, etc.)
to determine the chemical composition of the battery. Batteries must be recycled or returned to an
appropriate location (e.g. collection container) in accordance with local legal provisions.
Signal settings
1. Use a screwdriver to open the detector.
2. Set the DIP as required (all DIP switch positions are on by default).
- Position 1: turn o optical signal
- Position 2: turn o mechanical signal
- Position 3: turn o sound signal
6. Replace the seal, attach the front cover - make sure the correct location. Screw in,
tighten the screws to maintain IP protection.
Safe handling
Placement recommendations
Place the activated detector on a flat, non-conductive surface where flooding is likely.
The detector requires no maintenance and is intended for indoor use.
If a ood is detected, your immediate attention and action is required.
It is essential to identify the source of the ood and take appropriate action.
What to do when flood is detected
When handling a device unboxed it is important to avoid contact with
liquids. avoid unnecessary contact with the components of the device. Do
not touch the metal objects inside the unit.

3 / 3
AirSF-100S
5-10 kΩ
2-5 kΩ
2-15 kΩ
15-25 kΩ
0.5-2 kΩ
~0.03 kΩ
~2.2 kΩ
~5 kΩ
~5 kΩ
~18 kΩ
~1 k Ω
~1 k Ω
~1 k Ω
~1 k Ω
~1 k Ω
~2.2 kΩ
~2.2 kΩ
~2.2 kΩ
~18 kΩ
Technical parameters
Warning
Read the operating instructions before installing the device and putting it into opera-
tion. Instruction manual is designated for mounting and also for user of the device. It is
always a part of its packing. Installation and connection can be carried out only by a per-
son with adequate professional qualication upon understanding this instruction man-
ual and functions of the device, and while observing all valid regulations. Trouble-free
function of the device also depends on transportation, storing and handling. In case you
notice any sign of damage, deformation, malfunction or missing part, do not install this
device and return it to its seller. It is necessary to treat this product and its parts as elec-
tronic waste after its lifetime is terminated. Before starting installation, make sure that all
wires, connected parts or terminals are de-energized. While mounting and servicing ob-
serve safety regulations, norms, directives and professional, and export regulations for
working with electrical devices. Do not touch parts of the device that are energized – life
threat. To ensure the transmission of the radio signal, make sure that the devices in the
building where the installation is installed are correctly located. Unless otherwise stated,
the devices are not intended for installation in outdoor and damp areas, they must not
be installed in metal switchboards or in plastic cabinets with metal doors - this prevents
transmission of the radio frequency signal. iNELS Air is not recommended for control-
ling life-saving instruments or for controlling hazardous devices such as pumps, heaters
without thermostat, lifts, hoists, etc. - radio frequency transmission may be overshad-
owed by obstruction, interference, transmitter battery may be discharged etc., thereby
disabling the remote control.
Power supply
Battery power:
Battery life by frequency *:
1x 10 minutes
1x 60 minutes
1x 12 hours
1x 24 hours
Setting
Alarm Detection:
Battery status view:
DIP switch:
Acoustic signal:
Detection
Sensor:
Detection principle:
Response Time:
Measurement accuracy:
Sensitivity:
Indication
LED:
Communication
Protocol:
Transmitter frequency:
Range in open space:
Transmission power (max.):
Other parameters
Working temperature:
Storage temperature:
Operation position:
Mounting:
Protection degree:
Dimension:
Weight:
1x CR123A battery
0.3 year
1.5 years
4.5 years
5 years
message to the server,
vibration, optical and audible alarm
message to the server
Position 3: turn o sound signal
Position 2: turn o mechanical signal
Position 1: turn o optical signal
greater than 45 dB / 1m
contacts for ooding
contact between the sensor sensed liquid
2 s after connecting the scanning contacts
99.8 %
in the range 0.03 - 20 kΩ
broadcast, alarm
Sigfox
RCZ1 868 MHz
Approx. 50 km**
25 mW / 14 dBm
0…+50°C (Pay attention
to the operating temperature of batteries)
-20…+60°C
capture contacts for ooding downwards
loose
IP62
Ø 89 x 23 mm
92 g
Liquids suitable for detection
Type of liquid
Drinking water
Well water
River water
Rain water
Waste water
Seawater
Salt water
Natural / hard water
Chlorinated water
Condensed water
Milk
Milk serum
Fruit juices
Vegetable Juices
Broths
Wine
Beer
Coee
Soap toam
Inadmissible liquids
Conductivity of liquids
* Values are calculated under ideal conditions, without triggering an energy-intensive
alarm (vibration, light and sound signal)
** Depending on network coverage
• Demineralised water
• Deionised water
• Bourbon
• Gasoline
• Oil
• Liquid gases
• Para n
• Ethylene glycol
• Paints
• High alcohol-content liquids
Resistivity [Ωcm]*
* Resistivity characterizes the local conductivity or resistive properties of materials which
conduct electric current.
The company ELKO EP, as the manufacturer, is entitled to make technical modications to the
product, in the technical specication and product manual, without prior notication.
Other iNels Security Sensor manuals

iNels
iNels RFSF-1B User manual

iNels
iNels RFMD-100 User manual

iNels
iNels RFWD-100 User manual

iNels
iNels RFMD-100 User manual

iNels
iNels RFMD-100 User manual

iNels
iNels RFSF-1B User manual

iNels
iNels RFSF-100 User manual

iNels
iNels Elko AirSF-100L User manual

iNels
iNels DMD3-1 User manual

iNels
iNels RF KEY-40 User manual