Interface ITL Specifications

7418 East Helm Drive • Scosdale, Arizona 85260 • 480.948.5555 • www.interfaceforce.com
Operator Instrucons ISTL Tension Link v1.2 12-01-2017
Page 1 of 2
OPERATOR INSTRUCTIONS
FOR MODEL ITL TENSION
LINK LOAD CELL
Model ITL

7418 East Helm Drive • Scosdale, Arizona 85260 • 480.948.5555 • www.interfaceforce.com
Operator Instrucons ISTL Tension Link v1.2 12-01-2017
Page 2 of 2
TABLE OF CONTENTS
1. OPERATING INSTRUCTIONS
1.1 Introducon.......................................................................................................................1
1.2 Markings CE......................................................................................................................1
1.3 ElectromagnecCompability(EMC)................................................................................1
1.4 InstallaonandOperaon.................................................................................................1
1.5 Calibraon..........................................................................................................................3
1.6 Warnings / Hazards............................................................................................................3
1.7 InspeconandRepair........................................................................................................4
2. WARRANTY
2.1 Warranty............................................................................................................................ 5

7418 East Helm Drive • Scosdale, Arizona 85260 • 480.948.5555 • www.interfaceforce.com
Operator Instrucons ISTL Tension Link v1.2 12-01-2017
Page 1 of 5
1.1 Introducon
ThisinstruconmanualreferstotheInterfacemodelITLtensionlinktelemetryopons.Beforeinstallingor
operanganyInterfacetensionlink,thisandanyreferencedocumentsshouldbereadandunderstood.
IncompliancewiththeMachineryDirecve,Interfacetensionlinkloadcellswillbesuppliedwiththefollowing
documents:InstruconManualandCalibraonCercate.
1.2 Markings CE
Eachtensionlinkwillbemarkedwithanindividualserialnumber,CElabelandtheSWL(safeworkingload)of
the tension link.
1.3 ElectromagnecCompability(EMC)
The electromagnec compability of the load cell device can only be assessed in conjuncon with the enre
installaon, including its control systems. The machine builder who installs this partly completed machinery
into a machine is responsible for compliance with the EMC direcve.
1.4 InstallaonandOperaon
Toensuresafeandtrouble-freeinstallaonofthetensionlinkmeasuringdevice,thetensionlinkmustbe
properlytransportedandstored,professionallyinstalledandplacedinoperaon.
Unpacking
Beforeremovingthetensionlink,inspectthepackagingforsignsofdamageandimmediatelyinformthe
supplierifanydamageisfound.Unpackthetensionlinkcarefully,takingspecialcarewithcablesandbe
awaretothepossibilityofdamaginglow-rangedevicesbymishandling.Ensurethatcalibraonandinstrucon
informaonisnotinadvertentlydiscarded.
ChecksPriortoInstallaon
• Checkthatthetensionlinkhasbeensuitablyselectedfortheenvironmentitisbeingplacedinto.Any
adversetemperature,corrosiveorpotenallyexplosiveenvironmentsmayaecttheoperaonallifeand
thesafetyoftheproduct.
OPERATING INSTRUCTIONS
Installaon
Tensionlinkloadcellsarenormallyclassiedasportabledevices,andsothecorrectinstallaoniscricalto
ensuringproductlifecycle.Toavoiddamageorlossofaccuracyduringinstallaon,thefollowingpointsshould
befollowed.
• ThedireconoftheloadappliedtoalinkshouldbelinearasshowninFigure1.

7418 East Helm Drive • Scosdale, Arizona 85260 • 480.948.5555 • www.interfaceforce.com
Operator Instrucons ISTL Tension Link v1.2 12-01-2017
Page 2 of 5
Figure 1 Figure 2
• Ensurethetensionlinkloadcelldoesnotexperiencetorqueorbendingforcesduringoperaon.
• ThetensionlinkloadcellshouldonlybeloadedintensionusingtheØCholesasshowninFigure1.See
Figure2fortwocommonexamplesofinstallaons.
• ForopmalperformanceaghttolerancewiththeØCloadingholesisrecommended.
Electrical Checks
Thecorrectconneconofatensionlinktoaninstrumentiscricaltoachievingandmaintainingthe
performanceandreliabilityoftheloadcell.
• Tensionlinkcablingmustbekeptawayfromhighpowercablesandequipment,highoutputRFequipment
andinducveloadsandgenerators.
TensionLinkOutput
Whensengupyourtensionlinkthefollowingpointsshouldbeacknowledged:
• Thezeroloadoutputgivenonthecalibraoncercateistheoutputofthetensionlinkwhennoloadis
applied.Thisincludestheremovaloftheloadcausedbyanyliingaccessories.
• Theloadonaninstalledloadlinkwillcompriseoftheweightofyourassembly(includingsheaves,blocks,
shackles,ropes,hooksetc.)andtheacveload(loadlied).Therefore,theoutputwithnoacveloadwill
begreaterthanthezerooutputindicatedonthecalibraoncercate.
ChecksAerInstallaon
• Withthetensionlinkinstalled,checktomakesurethatthedisplayedoutputisnotnegave,asthismay
indicateeitherafaultoracompressiveforceisbeingappliedtothetensionlink.(SeeFigure1onprevious
page).

7418 East Helm Drive • Scosdale, Arizona 85260 • 480.948.5555 • www.interfaceforce.com
Operator Instrucons ISTL Tension Link v1.2 12-01-2017
Page 3 of 5
1.6 Warnings / Hazards
Tensionlinksarehighlystresseddevicesandcommonlyhavesafetyfactorsbetweenthreeandvemes
theratedcapacityunderstaccondions.Fagueapplicaonsandenvironmentalfactorscancontributeto
reducingthismargin.Theusershoulddeterminemediaeectsontheexposedtensionlinkmaterials.Wherea
corrosiveenvironmentispresent,tensionlinkscanoenbemanufacturedfromcorrosionresistantmaterials
or,alternavely,isolaonbarrierscanbeemployedbetweenthecorrosiveenvironmentandthetensionlink.
• Whenapplyingloadtothetensionlink,theoutputshouldincreaseintheposivedirecon.Usethe
calibraoncercateforreferenceastotheoutputobservedatcertainloads.
1.5 Calibraon
AllInterfacetensionlinkloadcellsarecalibratedintraceabletestmachinestobestsimulatenormalloading
condions.
Ourgoalistomatchtheloadingcondionsthatwouldbeexperiencedinservicebutitisnotpossibletototally
simulatetheon-sitestructureforeverytensionlinkmanufactured.Itisforthisreasonthatforopmum
systemaccuracy,acalibraoninthenalassemblyisrecommended.On-sitecalibraonshouldbeperformed
withtheinstrumentthatisbeingusedwiththistensionlinkloadcell.
Thefollowingpointsshouldbefollowedtoavoidpotenallyhazardoussituaons:
• Donotweldneartoinstalledtensionlinks,asleakagecurrentsmaydestroythetensionlink'selectric
circuits.
• Tensionlinksaresealedunitswhichmustnotbedismantled.Damagedtensionlinksshouldbereturnedto
Interfaceforrepairandre-calibraon.
• Theaccuracyofthesystemisdependentuponcorrectinstallaonofthetensionlink.
• Tensionlinkloadcellsmustnotbesubjectedtoshockloads,suchasusingahammertoforceanassembly
together(ngclevispinsintothemounngholes).
• Thetensionlinkloadcellshouldneverbeplacedinapotenalexplosiveenvironmentunlesstheproductis
suitablycered(ATEXorIECEx).
1.7 InspeconandRepair
Repair
InterfacereccomendsthatallpreparedandserviceoftensionlinkloadcellsbeperformedbyInterface.

7418 East Helm Drive • Scosdale, Arizona 85260 • 480.948.5555 • www.interfaceforce.com
Operator Instrucons ISTL Tension Link v1.2 12-01-2017
Page 4 of 5
Inspecon
AllInterfacetensionlinkloadcellsshouldbesubjecttoperiodicinspecon,whichshouldinclude,butisnot
exclusivetothefollowingchecks:
• Compleonofthesafetychecksaerinstallaon.
• Checkoutputatzeroload(shiinzerooset).Verifyagainstcalibraoncercate.
• Inspecttoseeifthetensionlinkhasbeendamaged/wornorchemicallyaacked(fromacorrosive
environmentorlubricantsetc.).
Loadmeasuringlinksaredesignedformanydiverseliingandweighingapplicaons.
hp://www.interfaceforce.com
IF IN DOUBT ABOUT ANY ASPECT OF THE SELECTION,
INSTALLATION OR USE OF A TENSION LINK,
CONTACT INTERFACE FOR ADVICE BEFORE INSTALLING
CE Approvals
EuropeanDirecve 2006/42/EC
BS-ENISO13849-1:2015
BS-ENISO13849-2:2015
WARRANTY
WARRANTY
AlltensionlinkloadcellproductsformInterfaceForceInc.,('Interface')arewarrantedagainstdefecve
materialandworkmanshipforaperiodof(1)oneyearfromthedateofpurchase.
Ifthe'Interface'productyoupurchaseappearstohaveadefectinmaterialorworkmanshiporfailsduring
normalusewithintheperiod,pleasecontactyourDistributor,whowillassistyouinresolvingtheproblem.Ifit
isnecessarytoreturntheproductto'Interface'pleaseincludeanotestangname,company,address,phone
numberandadetaileddescriponoftheproblem.Also,pleaseindicateifitisawarrantyrepair.
Thesenderisresponsibleforshippingcharges,freightinsuranceandproperpackagingtopreventbreakagein
transit.

7418 East Helm Drive • Scosdale, Arizona 85260 • 480.948.5555 • www.interfaceforce.com
Operator Instrucons ISTL Tension Link v1.2 12-01-2017
Page 5 of 5
'Interface'warrantydoesnotapplytodefectsresulngfromaconofthebuyersuchasmishandling,improper
interfacing,operaonoutsideofdesignlimits,improperrepairorunauthorizedmodicaon.
Nootherwarranesareexpressedorimplied.'Interface'specicallydisclaimsanyimpliedwarranesof
merchantabilityortnessforaspecicpurpose.Theremediesoutlinedabovearethebuyer'sonlyremedies.
'Interface'willnotbeliablefordirect,indirect,special,incidentalorconsequenaldamageswhetherbasedon
thecontract,tortorotherlegaltheory.
Anycorrecvemaintenancerequiredaerthewarrantyperiodshouldbeperformedby'Interface'approved
personnelonly.
Table of contents
Other Interface Measuring Instrument manuals

Interface
Interface 9840-400 User manual

Interface
Interface BlueDAQ BX8 User manual

Interface
Interface DMA2 Manual

Interface
Interface GOLD STANDARD User manual

Interface
Interface 9860 User manual

Interface
Interface INF1 User manual

Interface
Interface 9825 Instruction Manual

Interface
Interface INF1 Instruction Manual

Interface
Interface 9860 User manual

Interface
Interface 9325-NU User manual