Page 4
UNSWITCHED
BLK/ORG (120/277V)
WHT/BLK
COMMON
WHITE
VIOLET
VIOLET
SWITCHED OR
UNSWITCHED LINE
*LAMP
*AC / EMERGENCY
BLACK
WHITE BLUE
BLUE
YELLOW
YELLOW
BLUE
BLUE/WHT
RED/WHT
RED
YELLOW
UNIT
CONNECTOR
TBTS
COMMON
A.C.
Ballast EMERGENCY
BALLAST
2LRSB_CEC
TWO LAMP RAPID START BALLAST
WHT/BLK
WHT/RED
RED/BLK (+)
ATTENTION: DO NOT MATE CONNECTOR UNTIL INSTALLATION IS
COMPLETE AND AC POWER IS SUPPLIED.
TEST ACCESSORY LEADS- REFER TO INSTALLATION
INSTRUCTIONS FOR PROPER POLARITY WIRING.
LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS,
LAMPS OPERATION SECTION FOR VARIOUS OPTIONS
USE EITHER WHT/BLK LEAD FOR WIRING THE COMMON. REFER TO AC
INPUT WIRING ON ILLUSTRATION 3 OF INSTALLATION MANUAL.
YEL/BLK
MATE UNIT CONNECTOR AFTER INSTALLATION IS
COMPLETE AND AC POWER IS SUPPLIED
*LAMP
RED
RED
TYPICAL WIRING DIAGRAMS
For wiring diagrams of ballasts not shown, consult our Customer Service.
Rev. 1600
68324-062
1. ONE LAMP RAPID START BALLAST
2. TWO LAMP RAPID START BALLAST
3. TWO LAMP RAPID START BALLAST
4. THREE LAMP RAPID START BALLAST
5. ONE LAMP INSTANT START BALLAST
6. TWO LAMP INSTANT START BALLAST
7. THREE LAMP INSTANT START BALLAST
8. FOUR LAMP INSTANT START BALLAST
UNSWITCHED
BLK/ORG (120/277V)
WHT/BLK
COMMON
WHITE
VIOLET
VIOLET
SWITCHED OR
UNSWITCHED LINE
*LAMP
BLACK
WHITE BLUE
BLUE
RED
RED
BLUE
BLUE/WHT
RED/WHT
RED
YELLOW
UNIT
CONNECTOR
TBTS
COMMON
A.C.
Ballast EMERGENCY
BALLAST
1LRSB_CEC
ONE LAMP RAPID START BALLAST
WHT/BLK
WHT/RED
RED/BLK (+)
ATTENTION: DO NOT MATE UNIT CONNECTOR UNTIL INSTALLATION IS
COMPLETE AND AC POWER IS SUPPLIED.
TEST ACCESSORY LEADS- REFER TO INSTALLATION
INSTRUCTIONS FOR PROPER POLARITY WIRING.
LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS,
LAMPS OPERATION SECTION FOR VARIOUS OPTIONS
USE EITHER WHT/BLK LEAD FOR WIRING THE COMMON. REFER TO AC
INPUT WIRING ON ILLUSTRATION 3 OF INSTALLATION MANUAL.
YEL/BLK
MATE UNIT CONNECTOR AFTER INSTALLATION IS
COMPLETE AND AC POWER IS SUPPLIED
UNSWITCHED
BLK/ORG (120/277V)
WHT/BLK
COMMON
WHITE
VIOLET
VIOLET
SWITCHED OR
UNSWITCHED LINE
*LAMP
*AC / EMERGENCY
BLACK
WHITE
BLUE/WHT
BLUE/WHT
YELLOW
YELLOW
BLUE
BLUE/WHT
RED/WHT
RED
YELLOW
UNIT
CONNECTOR
TBTS
COMMON
A.C.
Ballast EMERGENCY
BALLAST
3LRSB_CEC
THREE LAMP RAPID START BALLAST
WHT/BLK
WHT/RED
RED/BLK (+)
ATTENTION: DO NOT MATE CONNECTOR UNTIL INSTALLATION IS
COMPLETE AND AC POWER IS SUPPLIED.
TEST ACCESSORY LEADS- REFER TO INSTALLATION
INSTRUCTIONS FOR PROPER POLARITY WIRING.
LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS,
LAMPS OPERATION SECTION FOR VARIOUS OPTIONS
USE EITHER WHT/BLK LEAD FOR WIRING THE COMMON. REFER TO AC
INPUT WIRING ON ILLUSTRATION 3 OF INSTALLATION MANUAL.
YEL/BLK
MATE UNIT CONNECTOR AFTER INSTALLATION IS
COMPLETE AND AC POWER IS SUPPLIED
*LAMP
RED
RED
*LAMP
BLUE
BLUE
UNSWITCHED
BLK/ORG (120/277V)
WHT/BLK
COMMON
WHITE
VIOLET
VIOLET
SWITCHED OR
UNSWITCHED LINE
*LAMP
BLACK
WHITE
BLUE
RED
BLUE
BLUE/WHT
RED/WHT
RED
YELLOW
UNIT
CONNECTOR
TBTS
COMMON
A.C.
Ballast EMERGENCY
BALLAST
1LISB_CEC
ONE LAMP INSTANT START BALLAST
WHT/BLK
WHT/RED
RED/BLK (+)
ATTENTION: DO NOT MATE CONNECTOR UNTIL INSTALLATION IS
COMPLETE AND AC POWER IS SUPPLIED.
TEST ACCESSORY LEADS- REFER TO INSTALLATION
INSTRUCTIONS FOR PROPER POLARITY WIRING.
LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS,
LAMPS OPERATION SECTION FOR VARIOUS OPTIONS
USE EITHER WHT/BLK LEAD FOR WIRING THE COMMON. REFER TO AC
INPUT WIRING ON ILLUSTRATION 3 OF INSTALLATION MANUAL.
5
5
YEL/BLK
MATE UNIT CONNECTOR AFTER INSTALLATION IS
COMPLETE AND AC POWER IS SUPPLIED
CONNECT THE BLUE/WHT AND RED/WHT WIRES TOGETHER
UNSWITCHED
BLK/ORG (120/277V)
WHT/BLK
COMMON
WHITE
VIOLET
VIOLET
SWITCHED OR
UNSWITCHED LINE
*LAMP
*AC / EMERGENCY
BLACK
WHITE
BLUE
RED
BLUE
BLUE/WHT
RED/WHT
RED
YELLOW
UNIT
CONNECTOR
TBTS
COMMON
A.C.
Ballast EMERGENCY
BALLAST
2LISB_CEC
TWO LAMP INSTANT START BALLAST
WHT/BLK
WHT/RED
RED/BLK (+)
ATTENTION: DO NOT MATE CONNECTOR UNTIL INSTALLATION IS
COMPLETE AND AC POWER IS SUPPLIED.
TEST ACCESSORY LEADS- REFER TO INSTALLATION
INSTRUCTIONS FOR PROPER POLARITY WIRING.
LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS,
LAMPS OPERATION SECTION FOR VARIOUS OPTIONS
USE EITHER WHT/BLK LEAD FOR WIRING THE COMMON. REFER TO AC
INPUT WIRING ON ILLUSTRATION 3 OF INSTALLATION MANUAL.
YEL/BLK
MATE UNIT CONNECTOR AFTER INSTALLATION IS
COMPLETE AND AC POWER IS SUPPLIED
*LAMP
BLUE
5CONNECT THE BLUE/WHT AND RED/WHT WIRES TOGETHER
5
UNSWITCHED
BLK/ORG (120/277V)
WHT/BLK
COMMON
WHITE
VIOLET
VIOLET
SWITCHED OR
UNSWITCHED LINE
*LAMP
*AC / EMERGENCY
BLACK
WHITE
BLUE
RED
BLUE
BLUE/WHT
RED/WHT
RED
YELLOW
UNIT
CONNECTOR
TBTS
COMMON
A.C.
Ballast EMERGENCY
BALLAST
3LISB_CEC
THREE LAMP INSTANT START BALLAST
WHT/BLK
WHT/RED
RED/BLK (+)
ATTENTION: DO NOT MATE CONNECTOR UNTIL INSTALLATION IS
COMPLETE AND AC POWER IS SUPPLIED.
TEST ACCESSORY LEADS- REFER TO INSTALLATION
INSTRUCTIONS FOR PROPER POLARITY WIRING.
LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS,
LAMPS OPERATION SECTION FOR VARIOUS OPTIONS
USE EITHER WHT/BLK LEAD FOR WIRING THE COMMON. REFER TO AC
INPUT WIRING ON ILLUSTRATION 3 OF INSTALLATION MANUAL.
YEL/BLK
MATE UNIT CONNECTOR AFTER INSTALLATION IS
COMPLETE AND AC POWER IS SUPPLIED
*LAMP
BLUE
*LAMP
BLUE
5CONNECT THE BLUE/WHT AND RED/WHT WIRES TOGETHER
5
UNSWITCHED
BLK/ORG (120/277V)
WHT/BLK
COMMON
WHITE
VIOLET
VIOLET
SWITCHED OR
UNSWITCHED LINE
*LAMP
*AC / EMERGENCY
BLACK
WHITE
BLUE
YELLOW
BLUE
BLUE/WHT
RED/WHT
RED
YELLOW
UNIT
CONNECTOR
TBTS
COMMON
A.C.
Ballast EMERGENCY
BALLAST
4LISB_CEC
FOUR LAMP INSTANT START BALLAST
WHT/BLK
WHT/RED
RED/BLK (+)
ATTENTION: DO NOT MATE UNIT CONNECTOR UNTIL INSTALLATION IS
COMPLETE AND AC POWER IS SUPPLIED.
TEST ACCESSORY LEADS- REFER TO INSTALLATION
INSTRUCTIONS FOR PROPER POLARITY WIRING.
LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS,
LAMPS OPERATION SECTION FOR VARIOUS OPTIONS
USE EITHER WHT/BLK LEAD FOR WIRING THE COMMON. REFER TO AC
INPUT WIRING ON ILLUSTRATION 3 OF INSTALLATION MANUAL.
YEL/BLK
MATE UNIT CONNECTOR AFTER INSTALLATION IS
COMPLETE AND AC POWER IS SUPPLIED
*LAMP
RED
*LAMP
BLUE
5CONNECT THE BLUE/WHT AND RED/WHT WIRES TOGETHER
*LAMP
YELLOW
RED 5
I-320-HE I-320-HE
UNSWITCHED
BLK/ORG (120/277V)
WHT/BLK
COMMON
WHITE
VIOLET
VIOLET
SWITCHED OR
UNSWITCHED LINE
*LAMP
*AC / EMERGENCY
BLACK
WHITE BLUE
BLUE
YELLOW
YELLOW
BLUE
BLUE/WHT
RED/WHT
RED
YELLOW
UNIT
CONNECTOR
TBTS
COMMON
A.C.
Ballast EMERGENCY
BALLAST
2LRSB_CEC_2
TWO LAMP RAPID START BALLAST
WHT/BLK
WHT/RED
RED/BLK (+)
ATTENTION: DO NOT MATE CONNECTOR UNTIL INSTALLATION IS
COMPLETE AND AC POWER IS SUPPLIED.
TEST ACCESSORY LEADS- REFER TO INSTALLATION
INSTRUCTIONS FOR PROPER POLARITY WIRING.
LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS,
LAMPS OPERATION SECTION FOR VARIOUS OPTIONS
USE EITHER WHT/BLK LEAD FOR WIRING THE COMMON. REFER TO AC
INPUT WIRING ON ILLUSTRATION 3 OF INSTALLATION MANUAL.
YEL/BLK
MATE UNIT CONNECTOR AFTER INSTALLATION IS
COMPLETE AND AC POWER IS SUPPLIED
*LAMP
RED
RED
Wiring and Troubleshooting Tips are available on-line at http://www.iotaengineering.com/wiringtips.pdf
UNSWITCHED
BLK/ORG (120/277V)
WHT/BLK
COMMON
WHITE
VIOLET
VIOLET
SWITCHED OR
UNSWITCHED LINE
*LAMP
*AC / EMERGENCY
BLACK
WHITE
BLUE
YELLOW
BLUE
BLUE/WHT
RED/WHT
RED
YELLOW
UNIT
CONNECTOR
TBTS
COMMON
A.C.
Ballast EMERGENCY
BALLAST
4LISB_CEC
FOUR LAMP INSTANT START BALLAST
WHT/BLK
WHT/RED
RED/BLK (+)
ATTENTION: DO NOT MATE UNIT CONNECTOR UNTIL INSTALLATION IS
COMPLETE AND AC POWER IS SUPPLIED.
TEST ACCESSORY LEADS- REFER TO INSTALLATION
INSTRUCTIONS FOR PROPER POLARITY WIRING.
LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS,
LAMPS OPERATION SECTION FOR VARIOUS OPTIONS
USE EITHER WHT/BLK LEAD FOR WIRING THE COMMON. REFER TO AC
INPUT WIRING ON ILLUSTRATION 3 OF INSTALLATION MANUAL.
MATE UNIT CONNECTOR AFTER INSTALLATION IS
COMPLETE AND AC POWER IS SUPPLIED
5CONNECT THE BLUE/WHT AND RED/WHT WIRES TOGETHER
I-320-HE I-320-HE
I-320-HE I-320-HE
I-320-HE
I-320-HE