manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. IRSAP
  6. •
  7. Heater
  8. •
  9. IRSAP THE RADIATOR COMPANY LYNX User manual

IRSAP THE RADIATOR COMPANY LYNX User manual

Other IRSAP Heater manuals

IRSAP 1095M0723 User manual

IRSAP

IRSAP 1095M0723 User manual

IRSAP WINGS 500 User manual

IRSAP

IRSAP WINGS 500 User manual

IRSAP THE RADIATOR COMPANY Sebino User manual

IRSAP

IRSAP THE RADIATOR COMPANY Sebino User manual

IRSAP FLECHE AIR 944 User manual

IRSAP

IRSAP FLECHE AIR 944 User manual

IRSAP Supplies4Heat SHERWOOD User manual

IRSAP

IRSAP Supplies4Heat SHERWOOD User manual

IRSAP TESI3 EH-600-8 User manual

IRSAP

IRSAP TESI3 EH-600-8 User manual

IRSAP TESI3 EF User manual

IRSAP

IRSAP TESI3 EF User manual

IRSAP TESI3 Elettrico User manual

IRSAP

IRSAP TESI3 Elettrico User manual

IRSAP RELAX HYBRID REHM092A Service manual

IRSAP

IRSAP RELAX HYBRID REHM092A Service manual

IRSAP 715M0118 User manual

IRSAP

IRSAP 715M0118 User manual

IRSAP The Radiator Company Lupin Electric User manual

IRSAP

IRSAP The Radiator Company Lupin Electric User manual

IRSAP Relax Twin Power User manual

IRSAP

IRSAP Relax Twin Power User manual

IRSAP RELAX RENOVA User manual

IRSAP

IRSAP RELAX RENOVA User manual

IRSAP BELLA 550 User manual

IRSAP

IRSAP BELLA 550 User manual

IRSAP THE RADIATOR COMPANY Ceres User manual

IRSAP

IRSAP THE RADIATOR COMPANY Ceres User manual

IRSAP Step E 775 User manual

IRSAP

IRSAP Step E 775 User manual

IRSAP SOUL User manual

IRSAP

IRSAP SOUL User manual

IRSAP 1234M0620 User manual

IRSAP

IRSAP 1234M0620 User manual

IRSAP ARES Series User manual

IRSAP

IRSAP ARES Series User manual

IRSAP THE RADIATOR COMPANY ISEO TRC-IS-O30 User manual

IRSAP

IRSAP THE RADIATOR COMPANY ISEO TRC-IS-O30 User manual

IRSAP THE RADIATOR COMPANY Uxbridge User manual

IRSAP

IRSAP THE RADIATOR COMPANY Uxbridge User manual

IRSAP KART User manual

IRSAP

IRSAP KART User manual

IRSAP 987M1220 User manual

IRSAP

IRSAP 987M1220 User manual

IRSAP 986M0421 User manual

IRSAP

IRSAP 986M0421 User manual

Popular Heater manuals by other brands

Porter-Cable PCXH80KT Operating instructions and owner's manual

Porter-Cable

Porter-Cable PCXH80KT Operating instructions and owner's manual

Dyna-Glo RA18LPDG user manual

Dyna-Glo

Dyna-Glo RA18LPDG user manual

Dimplex PLX050E instruction manual

Dimplex

Dimplex PLX050E instruction manual

EOS Herkules XL S120 installation instructions

EOS

EOS Herkules XL S120 installation instructions

Trebs Comfortheat 99209 manual

Trebs

Trebs Comfortheat 99209 manual

Biddle STYLE2 Series Installation operation & maintenance

Biddle

Biddle STYLE2 Series Installation operation & maintenance

Vermont Castings Non-Catalytic Convection Heater 2477CE Installation and operating manual

Vermont Castings

Vermont Castings Non-Catalytic Convection Heater 2477CE Installation and operating manual

Fagor RA-1505 Instructions for use

Fagor

Fagor RA-1505 Instructions for use

THERMAL FLOW Delta 175 Operating instructions manual

THERMAL FLOW

THERMAL FLOW Delta 175 Operating instructions manual

GET G2CH instructions

GET

GET G2CH instructions

ApenGroup PK Series User, installation, and maintenance manual

ApenGroup

ApenGroup PK Series User, installation, and maintenance manual

oventrop Regucor Series quick start guide

oventrop

oventrop Regucor Series quick start guide

Blaze King CLARITY CL2118.IPI.1 Operation & installation manual

Blaze King

Blaze King CLARITY CL2118.IPI.1 Operation & installation manual

ELMEKO ML 150 Installation and operating manual

ELMEKO

ELMEKO ML 150 Installation and operating manual

BN Thermic 830T instructions

BN Thermic

BN Thermic 830T instructions

KING K Series Installation, operation & maintenance instructions

KING

KING K Series Installation, operation & maintenance instructions

Empire Comfort Systems RH-50-5 Installation instructions and owner's manual

Empire Comfort Systems

Empire Comfort Systems RH-50-5 Installation instructions and owner's manual

Well Straler RC-16B user guide

Well Straler

Well Straler RC-16B user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Materials Stainless Steel
Connections ow and return.
Test pressure 5.2 Bar
Testing authority EN442
Maximum operating pressure 4 Bar
Maximum working temperature 90 ºC
Packaging Wrapped in polyester, in cardboard box with polystyrene
blocks
1
2
”
The Radiator Company
Units 13 - 14 Charlwoods Road
East Grinstead
West Sussex
RH19 2HU
All products must be inspected once removed from the packaging and The Radiator Company notied
within 28 days of delivery of any scratches, blemishes or other damage.
The Radiator Company will then replace the radiator.
Imperfect radiators should therefore not be tted and The Radiator Company will not accept responsibility
for replacement of scratched or damaged radiators once they have been tted. This includes any
consequential loss or cost of tting.
If The Radiator Company are not notied within 28 days of the date on the signed delivery note then it
will be deemed that The Radiator Company have fully complied with its obligations and claims will not be
considered.
Failure to comply with any of the above may invalidate any claims.
We recommend that after you check the product on delivery that it is stored in its packaging to prevent
damage prior to installation. The Radiator Company cannot accept responsibility for items damaged after
delivery.
Terms & Conditions
Guarantees & Liabilities
As we are not the manufacturers of this product we will take all reasonable endeavours to make over to
you the benet of any warranty or guarantee given by the manufacturer, which is usually ve years on most
of our range. (Copies of specic guarantees for any of our products are available on request).
The guarantees in all cases are subject to the products being installed in accordance with British and or
European standards as well as these tting instructions. The guarantees in all cases are restricted to the
free of charge replacement or repair of the failed product only. Our liability will under no circumstances
extend beyond the repair or replacement of the product supplied by us. Claims for either labour in
replacement or damage to property are not admissible. Any goods that are returned, in the event of a
problem, will belong to The Radiator Company.
Technical Specications
Please read these instructions and terms and
conditions carefully prior to installation.
Failure to do so may invalidate the warranty
Lynx
Fittings Instructions
10
Y
e
a
r
G
u
a
r
a
n
t
e
e
Y
e
a
r
G
u
a
r
a
n
t
e
e
THE
RADIATOR
COMPANY
LYNX_IR_1.0
PLEASE NOTE:Systemsusingmicroborepipeworkmusthaveadequatepressureandow
rates for the number and style of radiators on the system.
If you have any questions please contact us: 01342 302250, www.theradiatorcompany.co.uk A brand of , Italy’s leading manufacturer of design led radiators
Unpack & Inspect
1
You should have:
• 1 Radiator
• 4 Wall bracket sleeves & 4 grub screws (attached to radiator)
• 1 Airvent with Chrome Cap (pre-installed)
• 1 Blanking Plug with Chrome Cap (pre-installed)
• Wall xings; these are not suitable for wall types.
Please use suitable xings for your wall type.
You will need:
• Tape measure
• Electric drill and bits
• Spirit level
• Crosshead screwdriver
Contents
2
Hang Radiator
3
Diagrams of Lynx
The Radiator Company prides itself on selecting products from
manufacturers who exercise tight quality control measures.
We only select models with excellent standards of welding and
brazing, as well as high quality nishes.
All of our products are well packaged and should reach you in
perfect condition. Just in case however, we offer a 10-year no
quibble guarantee on this product.
The Radiator Company must be notied of any shortages or
damage within 28 days of delivery.
PLEASE NOTE : It is essential that all brackets are level to ensure a
vertical alignment for connecting the pipework.
Pipe Centres
Pipe centres left to right
Pipe centres from wall
Depth from wall
Commission
4
Please Note:
In accordance with Part L1 2006 of the Building Regulations and
BS7593:1992 code of practice for the treatment of hot water
and central heating systems, we strongly recommend flushing
the heating system post installation of new radiators and then
adding the correct quantity and type of inhibitor for use with
your radiator and system to prevent corrosion. Damage caused to
systems not protected by a suitable inhibitor will not be covered by
manufacturer’s guarantee.
430mm / width minus 70mm
55mm to 80mm
95mm to 120mm
For further information please see
terms and conditions on back page.
430
95 to 120 55 to 80
500
430
min. 110
Slide on the bracket sleeves over the
top two bracket studs on the back of
the radiator.
Lift the radiator in its nal desired place
and mark the position of the bracket.
Carefully set the radiator aside and
hold the top two bracket sleeves to the
wall on the markings, and mark through
the centre of the bracket for drilling.
Use a spirit level to check the markings
are horizontally aligned.
Using suitable drill bits, plugs and
screws, loosely x the top two brackets
to the markings. Check the position
by placing the radiator in position. If
correct, securely tighten the bracket
sleeves to the wall.
With the top two brackets xed, lift
the radiator into position on the top
two brackets (please ensure sufcient
support is given to the radiator at all
times)
Mark the position for the bottom two
brackets then repeat steps 1 to 3.
With all 4 bracket sleeves securely
attached to the wall, hang the radiator
and secure with the provided grub
screws into the side of the bracket
sleeves.
1.
2.
3.
5.
1.
2.
3.
4.
5.