manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. IRSAP
  6. •
  7. Heater
  8. •
  9. IRSAP Radiator Company Kura User manual

IRSAP Radiator Company Kura User manual

Materials Aluminium
Connections ow and return.
Test pressure 13 Bar
Testing authority EN442
Maximum operating pressure 10 Bar
Maximum working temperature 90 ºC
Packaging Double layered box with internal protection
1
2
”
The Radiator Company
Units 13 - 14 Charlwoods Road
East Grinstead
West Sussex
RH19 2HU
All products must be inspected once removed from the packaging and The Radiator
Company notified within 28 days of delivery of any scratches, blemishes or other damage.
The Radiator Company will then replace the radiator.
Imperfect radiators should therefore not be fitted and The Radiator Company will not accept
responsibility for replacement of scratched or damaged radiators once they have been fitted.
This includes any consequential loss or cost of fitting.
If The Radiator Company are not notified within 28 days of the date on the signed delivery
note then it will be deemed that The Radiator Company have fully complied with its
obligations and claims will not be considered.
Failure to comply with any of the above may invalidate any claims.
We recommend that after you check the product on delivery that it is stored in its packaging
to prevent damage prior to installation. The Radiator Company cannot accept responsibility
for items damaged after delivery.
Terms & Conditions
Guarantees & Liabilities
As we are not the manufacturers of this product we will take all reasonable endeavours to make
over to you the benet of any warranty or guarantee given by the manufacturer, which is usually
ve years on most of our range. (Copies of specic guarantees for any of our products are
available on request).
The guarantees in all cases are subject to the products being installed in accordance with British
and or European standards as well as these tting instructions. The guarantees in all cases are
restricted to the free of charge replacement or repair of the failed product only. Our liability will
under no circumstances extend beyond the repair or replacement of the product supplied by us.
Claims for either labour in replacement or damage to property are not admissible. Any goods
that are returned, in the event of a problem, will belong to The Radiator Company.
Technical Specications
Please read these instructions and terms and conditions carefully
prior to installation.
Failure to do so may invalidate the warranty
Kura
Fittings Instructions
5
Y
e
a
r
G
u
a
r
a
n
t
e
e
Y
e
a
r
G
u
a
r
a
n
t
e
e
THE
RADIATOR
COMPANY
KUR_IR_1.0
PLEASE NOTE: To reduce the possibility of noise caused by rapid heating and cooling
of aluminium radiators; adequate capacity for expansion must be provided within
the overall heating system. Systems using micro bore pipework must have adequate
pressure and flow rates for the number and style of radiators on the system.
If you have any questions please contact us: 01342 302250, www.theradiatorcompany.co.uk A brand of , Italy’s leading manufacturer of design led radiators
You should have:
1 Radiator
4 Brackets (consisting of two parts and a screw)
1 Fixed Diverter -
the diverter for the Kura is xed and cannot be
moved, it is positioned between the 1st and 2nd element from the left
(please see diagram opposite)
You will need:
Suitable drill bits, plugs and screws for your wall type
3mm Allen Key
Crosshead Screwdriver
Spirit Level
Drill
Contents
2
Diagrams of Kura
PLEASE NOTE :
It is essential that all brackets are level to ensure a vertical alignment for
connecting the pipe work.
4
Commission
5
Unpack & Inspect
1
The Radiator Company prides itself on selecting products from
manufacturers who exercise tight quality control measures. We
only select models with excellent standards of welding and
brazing, as well as high quality nishes. All of our products are well
packaged and should reach you in perfect condition. Just in case
however, we offer a minimum 5-year no quibble guarantee for all
radiators and towel rails.
Please carefully unpack and inspect this
radiator and all ttings.
The Radiator Company must be notied of
any shortages or damage within 28 days of
delivery. For further information please see
terms and conditions on back page.
In accordance with Part L1 2006 of the Building Regulations and
BS7593:1992 code of practice for the treatment of hot water and
central heating systems, we strongly recommend flushing the heating
system post installation of new radiators and then adding the correct
quantity and type of inhibitor for use with your radiator and system
to prevent corrosion. Damage caused to systems not protected by a
suitable inhibitor will not be covered by manufacturer’s guarantee.
Fix Brackets and Hang Radiator
Pipe Centres
Pipe centres left to right
Pipe centres from wall
Depth from wall
width - 15mm + Valves
30mm - 75mm
90mm - 135mm
Mark Bracket Positions
3
Same dimensions for all horizontal and vertical models:
85
85
65 65
width - 15mm + valves
(pipe centres)
Minimum
depth from wall & pipe centres from wall
90
30
135
75
Maximum
depth from wall & pipe centres from wall
1. Brackets are supplied xed to
the radiator. Loosen the L-Shape
bracket withan Allen Key, tilt
up (to the position shown) and
tighten.
2. Stickers are available to use on the L shape brackets to mark out the
bracket positions on the wall; the top layer needs to be peeled off, and
you can then lift your radiator and press against the wall, and the stickers
will stick to the wall in the bracket positions. If you prefer you can use the
dimensions in the diagrams opposite to mark out the bracket positions.
3. Remove the L-Shape bracket from the radiator
and x to the wall in the positions shown, using
a suitable drill bit, plugs and screws. Use a spirit
level to ensure the brackets are vertically and
horizontally level.
4. Lift up the radiator and place into position.
The top brackets will sit under the top collector
as support.
5. Using an allen key re-attach the L-Shape
Brackets to the bracket body on the top two
brackets rst, then the bottom.
6. The Brackets can slide along the collector to
alter the position of the radiator.
Ensure the radiator is in its nal position and
secure the brackets in place using a 3mm Allen
key on the grub screws on the bracket body.
60
60(recommended) (recommended)
x
x = xed diverter position

Other IRSAP Heater manuals

IRSAP TESI3 EF User manual

IRSAP

IRSAP TESI3 EF User manual

IRSAP 1095M0518 User manual

IRSAP

IRSAP 1095M0518 User manual

IRSAP ARES User manual

IRSAP

IRSAP ARES User manual

IRSAP JAZZ User manual

IRSAP

IRSAP JAZZ User manual

IRSAP THE RADIATOR COMPANY Athena User manual

IRSAP

IRSAP THE RADIATOR COMPANY Athena User manual

IRSAP THE RADIATOR COMPANY Sebino User manual

IRSAP

IRSAP THE RADIATOR COMPANY Sebino User manual

IRSAP Relax Twin Power User manual

IRSAP

IRSAP Relax Twin Power User manual

IRSAP FLAUTO User manual

IRSAP

IRSAP FLAUTO User manual

IRSAP THE RADIATOR COMPANY LYNX User manual

IRSAP

IRSAP THE RADIATOR COMPANY LYNX User manual

IRSAP 987M1220 User manual

IRSAP

IRSAP 987M1220 User manual

IRSAP 987M0622 User manual

IRSAP

IRSAP 987M0622 User manual

IRSAP 715M0118 User manual

IRSAP

IRSAP 715M0118 User manual

IRSAP RELAX HYBRID REHM092A Service manual

IRSAP

IRSAP RELAX HYBRID REHM092A Service manual

IRSAP TESI3 EH-600-8 User manual

IRSAP

IRSAP TESI3 EH-600-8 User manual

IRSAP FLECHE AIR 944 User manual

IRSAP

IRSAP FLECHE AIR 944 User manual

IRSAP RELAX RENOVA User manual

IRSAP

IRSAP RELAX RENOVA User manual

IRSAP VELA 700 User manual

IRSAP

IRSAP VELA 700 User manual

IRSAP BELLA 550 User manual

IRSAP

IRSAP BELLA 550 User manual

IRSAP TESI3 EH-600-8 User manual

IRSAP

IRSAP TESI3 EH-600-8 User manual

IRSAP 986M0421 User manual

IRSAP

IRSAP 986M0421 User manual

IRSAP NET 800 User manual

IRSAP

IRSAP NET 800 User manual

IRSAP SOUL User manual

IRSAP

IRSAP SOUL User manual

IRSAP WINGS 500 User manual

IRSAP

IRSAP WINGS 500 User manual

IRSAP The Radiator Company Lupin Electric User manual

IRSAP

IRSAP The Radiator Company Lupin Electric User manual

Popular Heater manuals by other brands

Kampmann Katherm HK Assembly, installation and operating instructions

Kampmann

Kampmann Katherm HK Assembly, installation and operating instructions

Dimplex CFH60 instructions

Dimplex

Dimplex CFH60 instructions

Fondital eGarda Installation, use and maintenance manual

Fondital

Fondital eGarda Installation, use and maintenance manual

Fenix GR 300 Mounting and operating instructions

Fenix

Fenix GR 300 Mounting and operating instructions

Jaga IGUANA ARCO ARCW Mounting instructions

Jaga

Jaga IGUANA ARCO ARCW Mounting instructions

JH 13W Series owner's manual

JH

JH 13W Series owner's manual

Sentiotec TH6-VR Instructions of installation

Sentiotec

Sentiotec TH6-VR Instructions of installation

TESY HL-202H Usage and Storage Instructions

TESY

TESY HL-202H Usage and Storage Instructions

Stadler Form Anna & Anna operating instructions

Stadler Form

Stadler Form Anna & Anna operating instructions

Omnitec VULCAN quick start guide

Omnitec

Omnitec VULCAN quick start guide

Bimar PICK Instruction booklet

Bimar

Bimar PICK Instruction booklet

DeLonghi KH39015CMCA Instructions for use

DeLonghi

DeLonghi KH39015CMCA Instructions for use

ProFitter RMC-FA300PF Operating instructions & parts manual

ProFitter

ProFitter RMC-FA300PF Operating instructions & parts manual

Thermoscreens T Series Operation and maintenance

Thermoscreens

Thermoscreens T Series Operation and maintenance

Beper P203PAN001 manual

Beper

Beper P203PAN001 manual

STIEBEL ELTRON CFK 50 Operation and installation

STIEBEL ELTRON

STIEBEL ELTRON CFK 50 Operation and installation

ARDES AR4P02 Instructions for use