manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. jablotron
  6. •
  7. Security Sensor
  8. •
  9. jablotron JA-181M User manual

jablotron JA-181M User manual

Other jablotron Security Sensor manuals

jablotron JA-60V User manual

jablotron

jablotron JA-60V User manual

jablotron JA-188P User manual

jablotron

jablotron JA-188P User manual

jablotron JA-111TH User manual

jablotron

jablotron JA-111TH User manual

jablotron JA-80S User manual

jablotron

jablotron JA-80S User manual

jablotron JA-151P-WW User manual

jablotron

jablotron JA-151P-WW User manual

jablotron JA-151TH User manual

jablotron

jablotron JA-151TH User manual

jablotron JA-152P User manual

jablotron

jablotron JA-152P User manual

jablotron JA-158P User manual

jablotron

jablotron JA-158P User manual

jablotron JA-80IR User manual

jablotron

jablotron JA-80IR User manual

jablotron JA-83P User manual

jablotron

jablotron JA-83P User manual

jablotron JK-16 PROFI User manual

jablotron

jablotron JK-16 PROFI User manual

jablotron JA-159P User manual

jablotron

jablotron JA-159P User manual

jablotron JA-158P User manual

jablotron

jablotron JA-158P User manual

jablotron JA-60V User manual

jablotron

jablotron JA-60V User manual

jablotron JA-122PW User manual

jablotron

jablotron JA-122PW User manual

jablotron JA-151P-WG User manual

jablotron

jablotron JA-151P-WG User manual

jablotron JA-151P-WW User manual

jablotron

jablotron JA-151P-WW User manual

jablotron JA-80S User manual

jablotron

jablotron JA-80S User manual

jablotron JA-81M User manual

jablotron

jablotron JA-81M User manual

jablotron JA-88P User manual

jablotron

jablotron JA-88P User manual

jablotron JA-158P User manual

jablotron

jablotron JA-158P User manual

jablotron JA-88P User manual

jablotron

jablotron JA-88P User manual

jablotron JA-180S User manual

jablotron

jablotron JA-180S User manual

jablotron JA-158P User manual

jablotron

jablotron JA-158P User manual

Popular Security Sensor manuals by other brands

Honeywell Home PROSiXCOCN Installation and setup guide

Honeywell Home

Honeywell Home PROSiXCOCN Installation and setup guide

Duevi SIRPZ-RB-868 Operation

Duevi

Duevi SIRPZ-RB-868 Operation

RKI 65-2483RK Operator's manual

RKI

RKI 65-2483RK Operator's manual

Nortech PD160 Enhanced Series user manual

Nortech

Nortech PD160 Enhanced Series user manual

Omron K8AC-H2 manual

Omron

Omron K8AC-H2 manual

Agilent Technologies G8610 Series Quick reference card

Agilent Technologies

Agilent Technologies G8610 Series Quick reference card

Shinko SE2EA-1-0-0 instruction manual

Shinko

Shinko SE2EA-1-0-0 instruction manual

Det-Tronics X Series instructions

Det-Tronics

Det-Tronics X Series instructions

ACR Electronics COBHAM RCL-300A Product support manual

ACR Electronics

ACR Electronics COBHAM RCL-300A Product support manual

TOOLCRAFT 1712612 operating instructions

TOOLCRAFT

TOOLCRAFT 1712612 operating instructions

Elkron IM600 Installation, programming and functions manual

Elkron

Elkron IM600 Installation, programming and functions manual

Bosch WEU PDO 6 Original instructions

Bosch

Bosch WEU PDO 6 Original instructions

THORLABS PDA10JT user guide

THORLABS

THORLABS PDA10JT user guide

Waeco UV-DETECT operating manual

Waeco

Waeco UV-DETECT operating manual

Intermatic IOS-DSIMF manual

Intermatic

Intermatic IOS-DSIMF manual

Siemens AZL66 Series manual

Siemens

Siemens AZL66 Series manual

BTI Profiline Multi Finder operating instructions

BTI

BTI Profiline Multi Finder operating instructions

Challenger SL01 instruction manual

Challenger

Challenger SL01 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

The JA-181M wireless magnetic door detector & universal transmitter
The JA-181M wireless magnetic door detector & universal transmitter 1/2 MHQ55800
The JA-181M is a component of Jablotron’s alarm system. It is
designed to detect the opening of doors, windows etc. It can also
be extended by a normally closed / normally open sensor. It is also
designed to detect the handling of roller blinds. This is achieved by
detecting CT-01 ratchet-wheel movements. Small movements are
filtered out so that wind blasts do not cause false alarms. The JA-
181M can be used with the LD-81 flood detector as well.
Installation
Installation shall only be undertaken by technicians holding a
certificate issued by an authorized distributor. This detector reacts
to the removal of its magnet unit. The electronics should be
installed onto the non-moving part of windows or doors, and the
magnet onto the moving part. The detector should be installed
vertically. Avoid locating it directly on a metal frame as metal
influences the functioning of the magnetic sensor and radio
communication. If the door or window is made of metal, we
recommend installing the detector unit away from the metal and
wiring up an external wired magnetic sensor which is connected to
the detector.
There are two different types of permanent magnets in the
package - a standard magnet in a plastic housing (A) and a whorl-
shaped magnet (B) for use in places where there is not enough
space for a standard magnet or for counter-sinking the magnet into
a door or window’s inner frame. The right positions for placing both
types of magnets against the internal magnetic sensor are shown
below as well as the reaction areas for magnets in millimeters in
three axes of movement.
See the following instructions:
1. Open the detector cover by pressing the tab in.
2. Screw the rear cover to the solid part of the door/window.
3. Attach the magnet to the moving part of the window. Its
distance from the detector should not exceed 5mm when the
door/window is closed. The lower edge of the magnet should
be aligned with the lower edge of the detector. Only a single
magnet can be installed, either on the left side or the right side
of the detector.
4. Leave the battery disconnected and the cover open and
then follow the control panel or receiver manual. The basics of
enrollment are:
xEnter enrollment mode on the control panel by keying in “1”
in Service mode
xInstall a battery into the detector to activate enrollment.
xExit enrollment mode by pressing “#”
5. To observe EN 50131-2-2 must be the tab must be secured by
the supplied screw.
To enroll a detector after having already connected a battery,
first disconnect the battery, and press and release the tamper
sensor to discharge any remaining charge to ready the device for
enrolment.
DIP switches
MG ON / MG OFF Allows the internal magnetic sensor inside
the detector to be disabled when the detector is only to be used
with external sensors wired to its terminals.
INS / DEL DEL provides entrance & exit delays for detectors
installed in a building entrance. INS allows the detector to instantly
trigger alarm activation if the control panel is armed. This DIP
switch (INS/DEL) only has an effect if the detector has a natural
reaction assigned to its address in the Jablotron control panel. It
also has no effect when used with a JA-182N or JA-180N receiver.
Opening the cover makes the detector react with a tamper
signal.
Open / closed status detection
The detector has two different modes. The mode is indicated
by one or two short flashes when the battery is inserted.
One flash means that it indicates both opening and closing the
door or window (factory default setting). The control panel knows
the status of doors / windows. Two flashes means the pulse mode
in which the detector indicates only opening the door or window.
The mode can be set (changed) when keeping the tamper switch
pressed while installing the battery for 3 to 5 seconds.
Wiring up the external sensor
External sensors can be wired to the detector. It is possible to
protect more doors / windows or to wire in other types of wired
detectors. The inputs IN2 and TMP react when disconnected from
the GND common terminal. The IN1 input can be used either as a
NC input or a balanced loop input (EOL resistor 1k). The function is
detected automatically.
IN1 If the IN1 terminal is disconnected from GND it sends the same
signal to the control panel as if the magnet had been removed
from the detector. The internal magnetic sensor can be disabled by
the DIP switch if desired.
The balanced loop feature can be used when the connection of a
detector with a NO output is needed. The resistor is then shorted
out by the closing contact and the detector is triggered.
Wiring example for NC … and NO contacts
IN2 The IN2 input terminal receives signals from the ratchet-
wheel CT-01. Alarm signals are then only transmitted when the
ratchet contact is opened at least three times within 10 seconds.
This filters out disconnections caused by accidental ratchet-wheel
shifts, which are due to wind blasts. When the IN2 input is opened
for more than 1 sec a tamper signal is sent.
Ratchet-wheel function scheme
TMP The TMP terminal sends a tamper signal to the control
panel if disconnected from GND.
Note: If any of these two inputs is not used, it must be shorted to
the GND terminal.
The maximum length of the cable for external detector
would not be longer than 3 meters.
Testing the detector
15 minutes after closing the detector cover, the LED indicates
detector triggering. The strength and quality of detector signals can
be measured by the control panel in Service mode.
Battery replacement
The detector monitors its battery voltage and if too low, a
transmission is sent to the control panel to inform the installer or
user. The detector continues to function and shows each triggering
of the detector with a flash of its LED. Battery replacement should
The JA-181M wireless magnetic door detector & universal transmitter
The JA-181M wireless magnetic door detector & universal transmitter 2/2 MHQ55800
not be delayed by more than two weeks. This should be done by a
qualified technician with the control panel in Service mode.
Expired batteries should not be thrown into the garbage, but
disposed of according to local regulations.
Removing the detector from the system
If a detector is removed, the control panel announces the
removal. The detector has to be deleted in the control panel before
intentional removal.
Technical parameters
Voltage Lithium battery type LS(T)14500 AA (3.6V / 2.4 Ah)
Typical battery lifetime approx. 3 years
for 20 daily activations maximum
Communication band 868.1 MHz, Jablotron protocol
Communication range approx. 300m (open area)
Typical sensitivity range of the built-in magnetic sensor
- see the picture
Inputs for external sensors IN2 and TMP = normally closed loops
IN1 normally closed or balanced loop (1k resistor)
The maximum length of the cable for external detectors 3 meters
Dimensions, weight 110 x 31 x 26 mm, 90g
magnet: 56 x 16 x 15 mm
Operational environment according to EN 50131-1II. Indoor general
Operational temperature range -10 to +40 °C
EN 50131-1, EN 50131-2-6, EN 50131-5-3 classification: grade 2
Complies with ETSI EN 300220, EN50130-4,
EN55022, EN 60950-1
Can be operated according to ERC REC 70-03
JABLOTRON ALARMS hereby declares that the
JA-181M is in compliance with the essential requirements
and other relevant provisions of Directive 1999/5/EC. The
original of the conformity assessment can be found at
www.jablotron.com, Technical Support section
Note: Although this product does not contain any harmful
materials we suggest you return the product to the dealer or
directly to the producer after use.