Kurth Electronic xDSL MultiTest KE3700 Instruction Manual

40
seit
1977
Your xDSL MultiTest guideline
Version 1/2017 Kurth Electronic, All Rights Reserved. Page 1

Version 1/2017 Kurth Electronic, All Rights Reserved. Page 2
Introduction xDSL
Introduction xDSL
KE3700 KE3550
F1 F2 F4F3
SEL
ESC
0
*
#
12
ABC
3
DEF
4
GHI
5
JKL
6
MNO
7
PQRS
8
TUV
9
WXYZ
VIEW
VOL
SPKR
SHIFT
ON-OFF
HELP
DSL
CRC
DSL
LOSS
DSL
L1
DSL
L2
SFP
Link
ETH
Link
USB2
Link
MGMT
Link
KE3700 xDSL M
ULTI
T
EST
L1 L2 L3 L4
SHDSL
®
Schnittstelle
Hilfe
Datum / Uhrzeit
Breitband
a/b: 0,0 V
2
Endgeräte Modus
Router Modus
Modem Modus
4
5
6
<xDSL>
xDSL Schnittstelle
3
Profile laden und speichern
1
G.FAST
7
<Ein>
F1 F2 F4F3
SEL
ESC
0
*
#
12
ABC
3
DEF
4
GHI
5
JKL
6
MNO
7
PQRS
8
TUV
9
WXYZ
VIEW
VOL
SPKR
SHIFT
ON-OFF
HELP
DSL
CRC
DSL
LOSS
DSL
L1
DSL
L2
ETH
Link
USB2
Link
MGMT
Link
KE3550
xDSL M
ULTI
T
EST
®
Schnittstelle
Hilfe
Datum / Uhrzeit
Breitband
a/b: 0,0 V
2
Endgeräte Modus
Router Modus
Modem Modus
4
5
6
<xDSL>
xDSL Schnittstelle
3
Profile laden und speichern
1
G.FAST
7
<Ein>
F1 F2 F4F3
SEL
ESC
0
*
#
12
ABC
3
DEF
4
GHI
5
JKL
6
MNO
7
PQRS
8
TUV
9
WXYZ
VIEW
VOL
SPKR
SHIFT
ON-OFF
HELP
DSL
CRC
DSL
LOSS
DSL
L1
DSL
L2
SFP
Link
ETH
Link
USB2
Link
MGMT
Link
KE3700
xDSL M
ULTI
T
EST
L1 L2 L3 L4
SHDSL
®
Schnittstelle
Hilfe
Datum / Uhrzeit
Breitband
a/b: 0,0 V
2
Endgeräte Modus
Router Modus
Modem Modus
4
5
6
<xDSL>
xDSL Schnittstelle
3
Profile laden und speichern
1
G.FAST
7
<Ein>
Ethernet 10/100/1000 Management,
Ethernet 10/100/1000 Test port, USB 2
ISDN analogue interface, SFP port
xDSL test port, power supply connection
Fastener for shoulder strap
Status LEDs
Speaker (Telephony)
Battery indicator
Sunlight readable TFT colour display
Connection: USB 1, SD card
Menu-sensitive function keys F1 – F4
Menu UP - DOWN / LEFT- RIGHT buttons
ON / OFF button
Microphone (Telephony)
Alphanumeric keypad
ESC (back) button
Select (enter) button
Display connection status SHDSL
Shift button: Function keys F5 – F8
View button: Back to main menu
Speaker button: Speakerphone
Vol button: Increase volume (3 levels)
button: Increase brightness (3 levels)
Help button: Open the help function

Version 1/2017 Kurth Electronic, All Rights Reserved. Page 3
Interfaces DSL and Ethernet
Interfaces DSL and Ethernet
Ethernet ports (device upper side) Device upper side
Device bottom
Yellow LED link/data: Physical connection layer 1 active
Green LED: Send/Recieve activity
xDSL ports (device bottom)
USB 2
ETH 2
1000 Mb/MGMT
ETH 1
1000 Mb
xDSL Test Port
12-18V/DC
1 GBit/s connection:
Ethernet tests 10/100/1000 MBit/s
Device management connection:
10/100/1000 MBit/s
USB connection: Feature extensions
(e.g. external Keyboard, external Data storage ...)
xDSL test connections: RJ11 / RJ45
External power cable connection
USB 3
xDSL Test Po r t
xDSL Test Port
12-18V/DC
USB2 100 Mb
Man agem ent
1000 Mb
USB 2
ETH 2
1000 Mb/MGMT
ETH 1
1000 Mb
Wi-Fi connection

Version 1/2017 Kurth Electronic, All Rights Reserved. Page 4
Interfaces SHDSL and S2M(KE3700 only)
Interfaces SHDSL and S2M(KE3700 only)
Device upper side
Device upper side
Alternate device upper side
Alternate device upper side
S2Mconnection
S2Mconnection
SHDSL connection
SHDSL connection
USB 2
100 Mb
Management
1000 Mb
POTS
ISDN-U
ISDN-S
S2M
SFP
SHDSL
USB 2
ETH 2
1000 Mb/MGMT
ETH 1
1000 Mb
USB 2
100 Mb
Management
1000 Mb
S2MSHDSL
USB 2 ETH 2
1000 Mb/MGMT
ETH 1
1000 Mb

Version 1/2017 Kurth Electronic, All Rights Reserved. Page 5
Interfaces ISDN/analogue and SFP port
(SFP KE3700 only)
Interfaces ISDN/analogue and SFP port (SFP KE3700 only)
Device upper side
Device upper side
SFP module slot copper/ber for
GPON and ethernet measurements
Warning: Do not perform a software
update with a slotted SFP module!
– S0connection
– UK0 connection
– Analogue telephone connection (POTS)
RJ45
RJ11
USB 2
ETH 2
1000 Mb/MGMT
ETH 1
1000 Mb
POTS
ISDN-U
ISDN-S
SFP

Version 1/2017 Kurth Electronic, All Rights Reserved. Page 6
Interfaces for fully-edged copper tests
Interfaces for fully-edged copper tests
SD card for e.g. long-time measurements,
loop tests
Warning: Insert/remoce SD card only when
the device is powered o!
KECT connection for copper tests line 1 and line
2 for 2x screened measuring lines with
3-pin TF connector on the device side
USB connection
KECT copper test module / optional (right device side)
Fully-edged
copper test
module for
qualication and
fault detection
on coax cables
Creation of
automatic tests
including
control function
for the KE905
loop test
assistant

Version 1/2017 Kurth Electronic, All Rights Reserved. Page 7
The innovative operating concept
The innovative operating concept
The symbols and signal colours
help with the conguration of the
tests and furthermore indicate
missing settings.
The tests are activated through
the left/right keys on the device.
Attention:
Red background = input /
verication absolutely
necessary!
activated → alle inputs complete → Test possible
activated → Complete input → Test possible
activated → Correct input → Test not possible
deacticated → activate with key

Version 1/2017 Kurth Electronic, All Rights Reserved. Page 8
Multitasking and 1-click-operation
Multitasking and 1-click-operation
nQuick transition between
views and tests with
function keys F1 – F4

Version 1/2017 Kurth Electronic, All Rights Reserved. Page 9
KE3x00 broadband menu xDSL
KE3x00 broadband menu xDSL
n Dierent modes can be accessed quickly
through the menu selection

Version 1/2017 Kurth Electronic, All Rights Reserved. Page 10
Conguration dial-in & data tests I (PPPoE)
Conguration dial-in & data tests I (PPPoE)
The data tests can be
performed in xDSL,
Ethernet (LAN) and with
KE3700 also in ber
optic environments.
If deviating from the
presettings, the interface
can be congured in this
menu.
Terminal mode
emulates PC, Smart-
phone, SIP telephone
for VoIP or an IPTV set-
top box including
TV picture.
Dial-in conguration with
input of the DSL access
data of the connection
holder.
Setting VLAN as well as
VPI and VCI.

Version 1/2017 Kurth Electronic, All Rights Reserved. Page 11
Conguration dial-in & data tests II (PPPoE)
using the example of a telecom connection
Conguration dial-in & data tests II (PPPoE) telecom connection
PPPoE dial-in with
dened VLAN ID 7 for
data and voice.
VPI: 1 / VCI: 32
IPTV as an IPoE
connection via VLAN 8.
Service Conguration →
Design Interface „Ja“ →
IPoE →DHCP...
Example shows the exe-
cution of the data tests.
Recommendation: Ping
test as well as FTP up-
and download-test.
After conguring and
activating the tests,
press „1“ or „Start“ to
start measurement.

Version 1/2017 Kurth Electronic, All Rights Reserved. Page 12
KE3x00 – xDSL measurements
KE3x00 – xDSL measurements

Version 1/2017 Kurth Electronic, All Rights Reserved. Page 13
xDSL connection setup (autotest)
xDSL connection setup (autotest)
Ready – Tester is ready
for a connection setup.
G.Handshake – G.hs
signal from the DSLAM
recieved at the far end.
Full Initialization –
Information exchange
and training phase.
Showtime – active
connection/synchroni-
zation. The connection
between the DSLAM
and the test device has
been successfully esta-
blished.

Version 1/2017 Kurth Electronic, All Rights Reserved. Page 14
Autotest at customer connection
Autotest at customer connection
Initial test to detect the xDSL service (ADSL, VDSL and VDSL vectoring)
Turn on device → Broadband → Terminal Mode → Press START
Important info
at a glance:
nDSL type and
Annex/variant
n Bandplan/Prole
nExternal voltage
nNet data rate
nSNR margin
nFEC
nCRC

Version 1/2017 Kurth Electronic, All Rights Reserved. Page 15
Evaluation dial-in & data tests I (PPPoE)
Evaluation dial-in & data tests I (PPPoE)
Conguration of a PPP
session (DSL) and
clear display of whether
the server connection
succeeded with IPv4 /
IPv6 info as well as new
status bar for the current
connection.
In the example, all
possible tests are con-
gured and the device is
already synchronized.
1. line, 2. data, 3. VoIP
and 4. IPTV
Convenient overview
of all active data tests
including VoIP and IPTV.
Individual views are also
available.

Version 1/2017 Kurth Electronic, All Rights Reserved. Page 16
Evaluation dial-in & data tests II (PPPoE)
Evaluation dial-in & data tests II (PPPoE)
A visual display of the
ping showing the trans-
mitted packets, packet
loss and transmission
times
Traceroute displays the
dierent routes to the
destination server
(destination host).
In the example:
www.t-online.de
Overview of running
HTTP downloads.
In the example:
5 parallel downloads
with an average rate
of 47 Mbps.
Example of 100% uploa-
ded FTP uploads with
3.4 to 4.4 Mbps upload
speed.

Version 1/2017 Kurth Electronic, All Rights Reserved. Page 17
Conguration VoIP test (PPPoE)
Conguration VoIP test (PPPoE)
First, the virtual interface
must be congured in
the terminal mode under
Data → Dial-in &
Modem conguration.
On request, detailed set-
tings to MOS threshold
are also possible.
Conguration of the
VoIP parameters inclu-
ding input of the data
for the SIP server to be
used.
After conguring and
activating the tests,
press „1“ or „Start“ to
start measurement.

Version 1/2017 Kurth Electronic, All Rights Reserved. Page 18
Evaluation VoIP test (PPPoE)
Evaluation VoIP test (PPPoE)
Example Customer connection with VoIP telephony: Select terminal device
mode → Congure VoIP customer recognition → Start test
Important info
at a glance:
nDSL type and
Annex/variant
n Bandplan/Prole
nExternal voltage
nConnection to
SIP server
nVoice connection
(acoustic)
nMOS value
nPackage loss
nDelay time
n Functional testing and qualication of the VoIP service
nQuality assessment based on the most important parameters

Version 1/2017 Kurth Electronic, All Rights Reserved. Page 19
KE3700 broadband menu SFP
KE3700 broadband menu SFP
nBroadband menu for tests at the optical port
nSFP level measurement, terminal and modem mode (conv.)

Version 1/2017 Kurth Electronic, All Rights Reserved. Page 20
KE3700 broadband menu ethernet
KE3700 broadband menu ethernet
nBroadband menu for tests at the ethernet port
nTerminal mode for IP test data, VoIP and IPTV
Other manuals for xDSL MultiTest KE3700
2
This manual suits for next models
1
Other Kurth Electronic Test Equipment manuals

Kurth Electronic
Kurth Electronic CCTS-03 User manual

Kurth Electronic
Kurth Electronic KE7200 User manual

Kurth Electronic
Kurth Electronic xDSL MultiTest KE3700 User manual

Kurth Electronic
Kurth Electronic xDSL MultiTest KE3700 Instruction Manual

Kurth Electronic
Kurth Electronic KE7200 User manual

Kurth Electronic
Kurth Electronic KE7200 User manual

Kurth Electronic
Kurth Electronic KE7100 User manual

Kurth Electronic
Kurth Electronic KE301 User manual