INSTALLATION PROCEDURE FOR PATHLIGHT:
1. Prepare footing as required by local codes, see Fig. 1 and Fig. 2 for
recommendations.
2. Set wooden anchor template in position over conduit.‘F’ on the template indicates
the Front of the unit. Make sure the ‘F’ faces up.
3. Mark four anchor hole locations and remove the template.
4. Drill holes according to anchor size and depth. Clear holes of debris.
5. Using the 2.5mm hex key, remove two screws to remove cabinet cover as shown in
Fig. 5.
6. Using the 13mm ratchet wrench, remove the two screws that attach the unit frame
to the base plate, as shown in Fig. 6.
7. Set base plate in position, ensuring that base sits flat on concrete, and install anchors
according to anchor manufacturer’s recommendations. The base plate is marked to
indicate the front of the unit.
8. Set unit body over base plate, see Fig. 8. Attach using two screws as shown in Fig. 6.
9. Make wiring connections.
10. Install cabinet cover as shown in Fig. 5.
Fig. 7 –Base plate
Landscape Forms is not responsible for site preparation and footings. Footing
recommendations are included in these instructions.
Installation Guide
Ashbery Path Light
www.landscapeforms.com Ph: 800.521.2546
Page 2 of 2
Date: March 19, 2021
Fig. 5 –Remove access panel Fig. 6 –Remove/install
base to body
ANCHORING
HARDWARE
NOT INCLUDED
M8 x 25mm
HEX CAP
SCREW
PORTION OF UNIT FRAME IS
NOT SHOWN FOR CLARITY
Fig. 8 –Install unit body over
installed base plate
PROCEDURE FOR WIRING ASHBERY PATHLIGHT:
The Ashbery path light is assembled at the factory. The light cartridge is mounted into
the head of the pole and will not need to be removed during installation. The LED
cartridge is wired to the driver (located in the cabinet) at the factory.
The following schematics are to be used to connect the unit to line voltage. It is the
responsibility of the installer to make sure that all connections are made in accordance
with the NEC and local building codes. Connection hardware not included.
Fig. 9 –Ashbery Pathlight wiring schematic
WARNING!: LED cartridge and driver are not rated for
connection or disconnection while energized. Doing so
may damage LEDs and will void the warranty.