Lanner NCA-5310 User manual

NCA-5310 User Manual
1
NCA-5310
User Manual
Version: 1.2
Date of Release:2021-08-26
Industrial Embedded
Platforms

NCA-5310 User Manual
2
This manual describes the overview of the various functionalities of this product, and the information you
need to get it ready for operation. It is intended for those who are:
-responsible for installing, administering and troubleshooting this system or Information Technology
professionals.
-assumed to be qualified in the servicing of computer equipment, such as professional system integrators,
or service personnel and technicians.
The latest version of this document can be found on Lanner’s official website, available either through the
product page or through the Lanner Download Center page with a login account and password.
This document utilizes different font types and icons in order to make selected text more transparent and
explicable to users. Please note that this document contains the following conventions:
Example
Convention
Usage
iptables –F
Monospace, shaded
A command to be entered at a shell
command-line
Setup page
Bold
A title of a dialog box or a page
<Enter>
Between a pair of inequality signs
A physical keyboard button
“Menu”
Between a pair of quotation marks
A menu option or a software button to be
clicked
Readme.txt
In Italic
A filename or a file path
IPMI User Guide
Underlined
The name of another document or a chapter
in this document
Icon
Usage
This mark indicates that there is something you should pay special
attention to while using the product.
This mark indicates that there is a caution or warning and it is
something that could damage your property or product.
Note or Information
Warning or Important

NCA-5310 User Manual
3
To obtain additional documentation resources and software updates for your system, please visit the Lanner
Download Center. As certain categories of documents are only available to users who are logged in, please
be registered for a Lanner Account at http://www.lannerinc.com/ to access published documents and
downloadable resources.
For troubleshooting the issues with your system, please check the Lanner Q&A page for a diagnostic
procedure and troubleshooting steps.
In addition to contacting your distributor or sales representative, you could use other available methods to
get support from Lanner:
Visit the Lanner Technical Support page at http://www.lannerinc.com/technical-support where you can fill
in a support ticket to our technical support department.
Phone support is offered to our customers in the United States and Canada.
Toll-free customer service number: +1 855-852-6637
This document is copyrighted © 2021 by Lanner Electronics Inc. All rights are reserved. The original
manufacturer reserves the right to make improvements to the products described in this manual at any time
without notice.
No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means
without the prior written permission of the original manufacturer.
Information provided in this manual is intended to be accurate and reliable. However, the original
manufacturer assumes no responsibility for its use, nor for any infringements upon the rights of third parties
that may result from such use.
Your feedback is valuable to us, as it will help us continue to provide you with more accurate and relevant
documentation. To provide any feedback, comments or to report an error, please email to
[email protected]m, Thank you for your time.

NCA-5310 User Manual
4
Taiwan Corporate Headquarters
Lanner Electronics Inc.
7F, No.173, Sec.2, Datong Rd. Xizhi District,
New Taipei City 22184, Taiwan
立端科技股份有限公司
221 新北市汐止區
大同路二段 173 號7樓
T: +886-2-8692-6060
F: +886-2-8692-6101
China
Beijing L&S Lancom Platform Tech. Co., Ltd.
Guodong LOFT 9 Layer No. 9 Huinan Road,
Huilongguan Town, Changping District,
Beijing 102208 China
T: +86 010-82795600
F: +86 010-62963250
E: service@ls-china.com.cn
USA
Lanner Electronics Inc.
47790 Westinghouse Drive
Fremont, CA 94539
T: +1-855-852-6637
F: +1-510-979-0689
E: sales_us@lannerinc.com
Canada
Lanner Electronics Canada Ltd
3160A Orlando Drive
Mississauga, ON
L4V 1R5 Canada
T: +1 877-813-2132
F: +1 905-362-2369
E: sales_ca@lannerinc.com

NCA-5310 User Manual
5
Intel® and Intel® Celeron® are trademarks of Intel Corporation or its subsidiaries in the U.S. and/or other
countries.
Microsoft Windows and MS-DOS are registered trademarks of Microsoft Corp.
All other product names or trademarks are properties of their respective owners.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the party responsible for compliance could void
the user's authority to operate this equipment.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Note
1. An unshielded-type power cord is required in order to meet FCC emission limits and also to prevent interference
to the nearby radio and television reception. It is essential that only the supplied power cord be used.
2. Use only shielded cables to connect I/O devices to this equipment.
3. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
Important
1. Operations in the 5.15-5.25GHz band are restricted to indoor usage only.
2. This device meets all the other requirements specified in Part 15E, Section 15.407 of the FCC Rules.

NCA-5310 User Manual
6
Follow these guidelines to ensure general safety:
Keep the chassis area clear and dust-free during and after installation.
Do not wear loose clothing or jewelry that could get caught in the chassis. Fasten your tie or scarf and roll
up your sleeves.
Wear safety glasses if you are working under any conditions that might be hazardous to your eyes.
Do not perform any action that creates a potential hazard to people or makes the equipment unsafe.
Disconnect all power by turning off the power and unplugging the power cord before installing or
removing a chassis or working near power supplies
Do not work alone if potentially hazardous conditions exist.
Never assume that power is disconnected from a circuit; always check the circuit.
Suivez ces consignes pour assurer la sécurité générale :
Laissez la zone du châssis propre et sans poussière pendant et après l’installation.
Ne portez pas de vêtements amples ou de bijoux qui pourraient être pris dans le châssis. Attachez votre
cravate ou écharpe et remontez vos manches.
Portez des lunettes de sécurité pour protéger vos yeux.
N’effectuez aucune action qui pourrait créer un danger pour d’autres ou rendre l’équipement dangereux.
Coupez complètement l’alimentation en éteignant l’alimentation et en débranchant le cordon
d’alimentation avant d’installer ou de retirer un châssis ou de travailler à proximité de sources
d’alimentation.
Ne travaillez pas seul si des conditions dangereuses sont présentes.
Ne considérez jamais que l’alimentation est coupée d’un circuit, vérifiez toujours le circuit. Cet appareil
génère, utilise et émet une énergie radiofréquence et, s’il n’est pas installé et utilisé conformément aux
instructions des fournisseurs de composants sans fil, il risque de provoquer des interférences dans les
communications radio.
There is risk of explosion if the battery is replaced by an incorrect type.
Dispose of used batteries according to the instructions.
Installation should be conducted only by a trained electrician or only by an electrically trained person who
knows all installation procedures and device specifications which are to be applied.
Do not carry the handle of power supplies when moving to another place.
Please conform to your local laws and regulations regarding safe disposal of lithium battery.
Disposal of a battery into fire or a hot oven, or mechanically crushing or cutting of a battery can result in
an explosion.
Leaving a battery in an extremely high temperature environment can result in an explosion or the leakage
of flammable liquid or gas.
A battery subjected to extremely low air pressure may result in an explosion or the leakage of flammable
liquid or gas.
Risque d’explosion si la pile est remplacée par une autre d’un mauvais type.
Jetez les piles usagées conformément aux instructions.
L’installation doit être effectuée par un électricien formé ou une personne formée à l’électricité
connaissant toutes les spécifications d’installation et d’appareil du produit.
Ne transportez pas l’unité en la tenant par le câble d’alimentation lorsque vous déplacez l’appareil.

NCA-5310 User Manual
7
Electrical equipment generates heat. Ambient air temperature may not be adequate to cool equipment to
acceptable operating temperatures without adequate circulation. Be sure that the room in which you
choose to operate your system has adequate air circulation.
Ensure that the chassis cover is secure. The chassis design allows cooling air to circulate effectively. An
open chassis permits air leaks, which may interrupt and redirect the flow of cooling air from internal
components.
Electrostatic discharge (ESD) can damage equipment and impair electrical circuitry. ESD damage occurs
when electronic components are improperly handled and can result in complete or intermittent failures.
Be sure to follow ESD-prevention procedures when removing and replacing components to avoid these
problems.
Wear an ESD-preventive wrist strap, ensuring that it makes good skin contact. If no wrist strap is available,
ground yourself by touching the metal part of the chassis.
Periodically check the resistance value of the antistatic strap, which should be between 1 and 10
megohms (Mohms).
L’équipement électrique génère de la chaleur. La température ambiante peut ne pas être adéquate pour
refroidir l’équipement à une température de fonctionnement acceptable sans circulation adaptée. Vérifiez
que votre site propose une circulation d’air adéquate.
Vérifiez que le couvercle du châssis est bien fixé. La conception du châssis permet à l’air de
refroidissement de bien circuler. Un châssis ouvert laisse l’air s’échapper, ce qui peut interrompre et
rediriger le flux d’air frais destiné aux composants internes.
Les décharges électrostatiques (ESD) peuvent endommager l’équipement et gêner les circuits électriques.
Des dégâts d’ESD surviennent lorsque des composants électroniques sont mal manipulés et peuvent
causer des pannes totales ou intermittentes. Suivez les procédures de prévention d’ESD lors du retrait et
du remplacement de composants.
Portez un bracelet anti-ESD et veillez à ce qu’il soit bien au contact de la peau. Si aucun bracelet n’est
disponible, reliez votre corps àla terre en touchant la partie métallique du châssis.
Vérifiez régulièrement la valeur de résistance du bracelet antistatique, qui doit être comprise entre 1 et 10
mégohms (Mohms).
Mounting Installation Precautions
The following should be put into consideration for rack-mount or similar mounting installations:
Do not install and/or operate this unit in any place that flammable objects are stored or used in.
The installation of this product must be performed by trained specialists; otherwise, a non-specialist might
create the risk of the system’s falling to the ground or other damages.
Lanner Electronics Inc. shall not be held liable for any losses resulting from insufficient strength for
supporting the system or use of inappropriate installation components.
Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient
temperature of the rack environment may be greater than room ambient. Therefore, consideration should
be given to installing the equipment in an environment compatible with the maximum ambient
temperature (Tma) specified by the manufacturer.
Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of airflow
required for safe operation of the equipment is not compromised.
Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition
is not achieved due to uneven mechanical loading.
Circuit Overloading - Consideration should be given to the connection of the equipment to the supply
circuit and the effect that overloading of the circuits might have on overcurrent protection and supply
wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this
concern.

NCA-5310 User Manual
8
Reliable Grounding - Reliable grounding of rack mounted equipment should be maintained. Particular
attention should be given to supply connections other than direct connections to the branch circuit (e.g.
use of power strips).
Warning
Class I Equipment. This equipment must be earthed. The power plug must be connected to a properly wired
earth ground socket outlet. An improperly wired socket outlet could place hazardous voltages on accessible
metal parts.
“Product shall be used with Class 1 laser device modules.”
Avertissement
Équipement de classe I. Ce matériel doit être relié à la terre. La fiche d’alimentation doit être raccordée à une
prise de terre correctement câblée. Une prise de courant mal câblée pourrait induire des tensions
dangereuses sur des parties métalliques accessibles.
“Le produit doit être utilisé avec des modules de dispositifs laser de classe 1.”
Before turning on the device, ground the grounding cable of the equipment. Proper grounding (grounding)
is very important to protect the equipment against the harmful effects of external noise and to reduce the
risk of electrocution in the event of a lightning strike. To uninstall the equipment, disconnect the ground
wire after turning off the power. A ground wire (green-and-yellow) is required and the part connecting the
conductor must be greater than 4 mm2 or 10 AWG.
Avant d’allumer l’appareil, reliez le câble de mise à la terre de l’équipement à la terre.
Une bonne mise à la terre (connexion à la terre) est très importante pour protéger l’équipement contre les
effets néfastes du bruit externe et réduire les risques d’électrocution en cas de foudre.
Pour désinstaller l’équipement, débranchez le câble de mise à la terre après avoir éteint l’appareil.
Un câble de mise à la terre est requis et la zone reliant les sections du conducteur doit faire plus de 4 mm2
ou 10 AWG.
Connect the grounding cable to the ground.
The protection device for the DC power source must provide 30 A
current.
This protection device must be connected to the power source
before DC power.

NCA-5310 User Manual
9
Branchez le câble de mise à la terre àla terre.
L’appareil de protection pour la source d’alimentation CC doit
fournir 30 A de courant.
Cet appareil de protection doit être branché à la source
d’alimentation avant l’alimentation CC.
This equipment must be grounded. The power cord for product should be connected to a socket-outlet
with earthing connection.
Cet équipement doit être mis à la terre. La fiche d'alimentation doit être connectée à une prise de terre
correctement câblée
Suitable for installation in Information Technology Rooms in accordance with Article 645 of the National
Electrical Code and NFPA 75.
Peut être installé dans des salles de matériel de traitement de l'information conformément à l'article 645
du National Electrical Code et àla NFPA 75.
The machine can only be used in a restricted access location and must be installed by a skilled person.
Les matériels sont destinés àêtre installés dans des EMPLACEMENTS À ACCÈS RESTREINT.
Important
1. The product is only to be connected to network without routing to outside plant.
2. The product is intended to be supplied UL listed DC power source with rated -48V to -60 Vdc, 22A minimum.
Maximum operating ambient is 40°C minimum and the altitude of operation = 5000m minimum. The power cable
should use 12 AWG minimum. If further assistance is required, please contact Lanner Technical Support.

NCA-5310 User Manual
10
Main Features.................................................................................................................................12
Package Content.............................................................................................................................12
Optional Accessories ......................................................................................................................12
Ordering Information .....................................................................................................................12
System Specifications.....................................................................................................................13
Front Panel .....................................................................................................................................14
Rear Panel.......................................................................................................................................15
Motherboard Information..............................................................................................................16
Opening the Chassis .......................................................................................................................24
Installing the CPU ...........................................................................................................................24
Installing the Disk Drive(s)..............................................................................................................27
Installing the TPM Module .............................................................................................................29
Installing the NIC Modules .............................................................................................................30
Installing the IPMI card...................................................................................................................32
Installing the System Memory .......................................................................................................33
Installing the M.2 Storage ..............................................................................................................34
Replacing the Cooling Fans.............................................................................................................35
Mounting the System.....................................................................................................................36
Entering Setup................................................................................................................................40
Main Page.......................................................................................................................................41
Advanced Page ...............................................................................................................................42
Chipset............................................................................................................................................64

NCA-5310 User Manual
11
Security...........................................................................................................................................67
Save and Exit Menu........................................................................................................................71
AMD CBS.........................................................................................................................................73
AMD PBS Option.............................................................................................................................82
Event Logs.......................................................................................................................................83

NCA-5310 User Manual
12
The NCA-5310 series unit is a high performance 1U Rack mount network security system utilizing the cutting-
edge capabilities of the AMD Rome/Naples platform with one EPYC 7000 Series CPU.
AMD EPYC 7000 Series w/ Support for Naples (up to 32C64T) & Rome (up to 64C128T)
8x 288-pin DIMM, Max. 512GB DDR4 3200MHz ECC R-DIMM
1x GbE RJ45 Intel® i210, Max. 4x NIC Module Slots
Max. 2x 2.5” Bays, 1x RJ45 Console, 1x PCIe*8 FHHL
Your package contains the following items:
1x NCA-5310 Network Security Platform
2x Power cable
1x Ear Rack mount kit with screws
1x Console cable
1x LAN Cable (Grey)
2x SATA cable
SKU No.
Main Features
NCA-5310A
AMD EYPC 7000 Series, w/ Support for Naples (up to 32C64T) and Rome (up to 64C128T),
1x GbE RJ45, 4x NIC Module Slots, 1x Console
Part No.
Description
PSE2811-111
TPM 2.0 Module
PSE7129-010
IPMI Card (for AMD Series)
AV-ICE06
Crypto Card
A SKU: PSE5694-010; B SKU: PSE5693-010; C SKU: PSE5695-010
PSF8546-001
Front NIC Kit, cable kit for front external NIC modules (Support PCIe Gen4)
PSF8547-001
Rear PCIE Kit, cable kit for rear PCIe slot (Support PCIe Gen4)
0P1W000152000
DC 900W Power Supply Unit
098W000300014
1U Slider Rail Kit, width: 438mm; Load:27kg; Tool-less
PSF8545-001
Fan Kit
Note If you should find any components missing or damaged, please contact your dealer immediately
for assistance.

NCA-5310 User Manual
13
Form Factor
1U 19” Rackmount
Platform
Processor Options
AMD EPYC 7000 Series w/ Support for Naples (up to 32C64T) &
Rome (up to 64C128T)
CPU Socket
SP3
Chipset
N/A
Security Acceleration
40Gbps Encryption + 40Gbps Decryption
BIOS
AMI SPI Flash BIOS
System Memory
Technology
DDR4 3200MHz ECC REG DIMM
Max. Capacity
512GB
Socket
8x 288-pin DIMM
Networking
Ethernet Ports (By SKU)
1 x GbE RJ45 Intel® i210
Bypass
N/A
NIC Module Slot
4
LOM
IO Interface
1 x RJ45
OPMA slot
Yes
I/O Interface
Reset Button
1
LED
Power/Status/Storage
Power Button
1 x ATX Power Switch
Console
1 x RJ45
USB
2 x USB 3.0
LCD Module
N/A
Display
AC Power Inlet on PSU
Storage
HDD/SSD Support
2 x 2.5” Bays
Onboard Slots
1 x 22110/2280 M.2 Slot
Expansion
PCIe
1 x PCIe*8 FHHL
Miscellaneous
Watchdog
Yes
Internal RTC with Li Battery
Yes
TPM
Yes (Optional)
Cooling
Processor
Passive CPU Heatsink
System
5 x Individual Hot-swappable Cooling Fans
Environmental
Parameters
Temperature
0~40ºC Operating
-20~70ºC Non-Operating
Humidity (RH)
5~90% Operating
5~95% Non-Operating
System Dimensions
(WxDxH)
438 x 610 x 44 mm
Weight
18 kg
Package
Dimensions
(WxDxH)
739 x 582 x 215 mm
Weight
19.5 kg
Power
Type/Watts
550W 1+1 ATX Redundant PSUs
Input
AC 100V~240V @47~63Hz
Approvals and Compliance
RoHS, CE/FCC, UL

NCA-5310 User Manual
14
No.
Description
F1
Reset button
For software reset
F2
LED Indicators
F3
USB Ports
2x USB 3.0
F4
RJ45 Port
1x RJ45 port
F5
Console Port
1x Console port
F6
NIC Module Slot
4x NIC Slots
F4
F1
F2
F3
F5
System Power
System Status
HDD Activity
F6

NCA-5310 User Manual
15
No.
Description
R1
Power Supply
2 x 800W Redundant PSU
R2
Fans
5 x Hot-swappable Cooling Fans
R3
Power Switch
1 x Power Button
R1
R2
R3

NCA-5310 User Manual
16
The block diagram indicates how data flows among components on the motherboard. Please refer to the
following figure for your motherboard’s layout design.

NCA-5310 User Manual
17
The motherboard layout shows the connectors and jumpers on the board. Refer to the following picture as a
reference of the pin assignments and the internal connectors.

NCA-5310 User Manual
18
The pin headers on the motherboard are often associated with important functions. With the shunt (Jumper)
pushed down on the designated pins (the pin numbers are printed on the circuit board, surrounding the pin
header), certain feature can be enabled or disabled. While changing the jumpers, make sure your system is
turned off.
Jumper Setting
To short the designated pins, push the jumper down on them so that they become SHORT. To make the pins
setting OPEN, simply remove the jumper cap.
2-pin Header
3-pin Header
4-pin Header
Open Short
Open (1-2) Jumped
Open (1-2) Jumped
JUSB1: USB2.0
Pin No.
Description
Pin No.
Description
1
P5V_USB1
2
3
USB20_L_N3
4
5
USB20_L_P3
6
7
USBGND1
8
9
USBGND1
10
JTPM1
Pin No.
Description
Pin No.
Description
1
P0_SERIRQ
2
P0_LFRAME_L
3
P0_LAD0
4
TPM_LPCCLK
5
P0_LAD1
6
P3V3_SB
7
P0_LAD2
8
9
P0_LAD3
10
P3V3
11
TPM_RST#
12
GND
ATX4: 24 Pin Power Connector
Pin No.
Description
Pin No.
Description
2
12VSB
1
GND
4
5V
3
GND
6
12V
5
GND
8
12V
7
GND
1
2
1
2
3
4
1
3
2
2
10
9
1
2
11
12
1

NCA-5310 User Manual
19
10
12V
9
GND
12
12V
11
GND
14
12V
13
GND
16
12V
15
GND
18
12V
17
GND
20
12V
19
GND
22
3V
21
GND
24
3V
23
GND
JATX4~6: 4 pin Power Connector
Pin No.
Description
Pin No.
Description
1
GND
2
GND
3
P3V3
4
P12V
JATXP12V: 4 pin Power Connector (Reserve)
Pin No.
Description
Pin No.
Description
1
GND
2
GND
3
P12V
4
P12V
JSATA1~JSATA4: SATA
Pin No.
Description
1
GND
2
TX_P
3
TX_N
4
GND
5
RX_N
6
RX_P
7
GND
SATAPWR1/2: 4 pin Power Connector
Pin No.
Description
Pin No.
Description
1
P12V
2
GND
3
GND
4
P5V
JFAN1~5: and JFAN_MID: FAN Connector
Pin No.
Description
1
Ground
2
12V
3
RPM Sense

NCA-5310 User Manual
20
4
RPM Sense
5
PWM Status
JGP1: EXT GPIO header
Pin No.
Description
Pin No.
Description
1
GPO_B_1
2
GPI_B_1
3
GPO_B_2
4
GPI_B_2
5
GPO_B_3
6
GPI_B_3
7
GPO_B_4
8
GPI_B_4
9
GND
10
GND
JNGFF3
Pin No.
Description
Pin No.
Description
1
GND
2
P3V3
3
GND
4
P3V3
5
PCIE_M2TX_C_PRX_N7
6
X
7
PCIE_M2TX_C_PRX_P7
8
X
9
GND
10
M.2_LED_N
11
PCIE_PTX_M2RX_N7
12
P3V3
13
PCIE_PTX_M2RX_P7
14
P3V3
15
GND
16
P3V3
17
PCIE_M2TX_C_PRX_N6
18
P3V3
19
PCIE_M2TX_C_PRX_P6
20
X
21
GND
22
X
23
PCIE_PTX_M2RX_N6
24
X
25
PCIE_PTX_M2RX_P6
26
X
27
GND
28
X
29
PCIE_M2TX_C_PRX_N5
30
X
31
PCIE_M2TX_C_PRX_P5
32
X
33
GND
34
X
35
PCIE_PTX_M2RX_N5
36
X
37
PCIE_PTX_M2RX_P5
38
N
39
GND
40
X
41
PCIE_M2TX_C_PRX_N4
42
X
43
PCIE_M2TX_C_PRX_P4
44
X
45
GND
46
X
47
PCIE_PTX_M2RX_N4
48
X
49
PCIE_PTX_M2RX_P4
50
NGFF_M2_RST#
51
GND
52
NGFF_CLKREQ#
This manual suits for next models
1
Table of contents
Other Lanner Industrial PC manuals

Lanner
Lanner LEC-7920 User manual

Lanner
Lanner LEC-3034A User manual

Lanner
Lanner LEC-2137B User manual

Lanner
Lanner LEC-2260A User manual

Lanner
Lanner LEC-7230 User manual

Lanner
Lanner LEC-2290 User manual

Lanner
Lanner LEC-2580 User manual

Lanner
Lanner LEC-3031 Series User manual

Lanner
Lanner HTCA-6600 User manual

Lanner
Lanner LEC-2270 User manual
Popular Industrial PC manuals by other brands

Moxa Technologies
Moxa Technologies CP-132 user manual

Beckhoff
Beckhoff CP62 Series Installation and operating instructions

Avalue Technology
Avalue Technology EMS-SKLU Quick reference guide

VIA Technologies
VIA Technologies ART-3000 quick guide

Siemens
Siemens SIMATIC Box PC 840 manual

Leica
Leica iCON excavate iCP41 user manual