LES 36… - 04 2014/06
Specifications
Optical data
Measurement range 1)
1) Luminosity coefficient 6% ... 90%, entire detection range, at 20°C after 30minutes warmup time, medium range UB
200 … 800mm (zdirection)
Light source laser
Wavelength 658nm (visible red light)
Max. output power < 8mW
Pulse duration < 3ms (adjustable from 0.1ms … 1.31ms)
Laser line 600x3mm at 800mm
Error limits (relative to measurement distance)
Resolution in xdirection 2) 3) 1…1.7mm
Resolution in z2)direction 3)
2) Minimum and maximum value depend on measurement distance
1…3mm
Linearity in zdirection 3)
3) Reflectivity 90%, identical object, identical environment conditions, measurement object ≥50x50mm²
≤±1%
Repeatability in zdirection 3) ≤0.5%
B/W detection thresh. (6 … 90% rem.) ≤1%
Object detection
Minimum object size in xdirection 4)
4) Minimum value, depends on distance and object, requires testing under application conditions
2…3mm
Minimum object size in zdirection 2) 2…6mm
Timing
Measurement time ≥10ms (configurable)
Delay before start-up approx. 1.5s
Electrical data
Operating voltage UB5)
5) For UL applications: for use in class 2 circuits according to NEC only
18 … 30VDC (incl. residual ripple)
Residual ripple ≤15% of UB
Open-circuit current ≤200mA
Ethernet interface UDP
Switching outputs 4 / 100mA / push-pull 6) on X3 (LES 36/VC6 only)
1 (ready) / 100mA / push-pull 6) on X1
1 (cascading) / 100mA / push-pull 6) on X1
6) The push-pull switching outputs must not be connected in parallel
Inputs 3 (selection of inspection task) on X3 (LES 36/VC6 only)
1 (trigger) on X1
1 (activation) on X1
Signal voltage high/low ≥(UB-2V)/≤2V
Analog output (LES 36/VC6)
Analog output voltage 1 … 10V, RL≥2kΩ
current 4 … 20mA, RL≤500Ω
PROFIBUS (only LES 36/PB)
Interface type 1x RS 485 on X4
Protocols PROFIBUS DP/DPV1 slave
Baud rate 9.6kBaud … 6MBaud
Indicators
Green LED continuous light ready
off No voltage
Yellow LED continuous light Ethernet connection available
flashing Ethernet data transmission active
off no Ethernet connection available
Mechanical data
Housing aluminum frame with plastic cover
Optics cover glass
Weight 620g
Connection type M12 connector
Environmental data
Ambient temp. (operation/storage) -30°C … +50°C/-30°C … +70°C
Protective circuit 7)
7) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs, requires external
potective circuit for inductive loads
1, 2, 3
VDE safety class III, protective extra-low voltage
Protection class IP 67
Laser class 2M (according to EN 60825-1 and 21 CFR 1040.10 with Laser
Notice No. 50)
Standards applied IEC/EN 60947-5-2
Certifications UL 508, C22.2 No.14-13 5) 8)
8) These sensors shall be used with UL Listed Cable assemblies rated 30V, 0.5A min,
in the field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7)
Tables
LED State Display during
measurement
operation
green continu-
ous light
Sensor ready
off Sensor not ready
yel-
low
continu-
ous light
Ethernetconnection
established
flashing Ethernet data trans-
mission active
off No Ethernet
connection
Diagrams
150
200
250
300
350
400
450
500
550
600
200 300 400 500 600 700 800
Line length (typical)
Distance in mm
Line length in mm
0
0,5
1,0
1,5
2,0
2,5
3,0
3,5
200 300 400 500 600 700 800
X
Z
Resolution (typical)
Distance in mm
Resolution in mm
LES 36
Remarks
Warmup time:
After a warmup time of
30 min., the light section sen-
sor has reached the operating
temperature required for an
optimum object measure-
ment.
Operate in accordance with
intended use!
This product is not a safety sensor
and is not intended as personnel
protection.
The product may only be put into
operation by competent persons.
Only use the product in accor-
dance with the intended use.