ODSL 8/V66-45-S12 - 06 2018/12
ODSL 8/C66-45-S12 - 06
Specifications
Optical data
Measurement range 1)
1) Luminosity coefficient 6% … 90%, at 20°C, measurement object ≥20x20mm²
25 … 45mm
Resolution 2)
2) Minimum and maximum value depend on measurement distance and configuration of the analog output
0.03mm
Light source laser
Laser class 2 acc. to IEC 60825-1:2007
Wavelength 650nm (visible red light)
Max. output power <1.2 mW
Pulse duration 4ms
Light spot Ø 1mm at 45mm
Error limits (relative to measurement distance)
Absolute measurement accuracy 1) ±1,5%
Repeatability 3)
3) Same object, identical environmental conditions, measurement object ≥20x20mm²
±0.2%
B/W detection thresh. (6 … 90% rem.) ≤1,5%
Temperature drift ≤ 0.2%/°C
Timing
Measurement time 2 … 7ms
Response time ≤20ms
Delay before start-up ≤300ms
Electrical data
Operating voltage UB18 … 30VDC (incl. residual ripple)
Residual ripple ≤15% of UB
Open-circuit current ≤50mA
Switching output/function4)
4) The push-pull switching outputs must not be connected in parallel
2 push-pull switching outputs
pin 2: Q2, PNP light switching, NPN dark switching
pin 4: Q1, PNP light switching, NPN dark switching
Signal voltage high/low ≥(UB-2 V)/≤2V
Analog output voltage 1 … 10V, RL≥2kΩ/ current 4 … 20mA, RL<500Ω
Indicators
Green LED continuous light ready
flashing (no teach) fault, teach values were not applied
off no voltage
Yellow LED continuous light object within teach-in measurement distance (output Q1 5))
5) No display for output Q2
flashing (no teach) teach values were not applied
off object outside teach-in measurement distance (output Q1 6))
Mechanical data
Housing metal
Optics cover glass
Weight 70g
Connection type M12 connector, 5-pin, turning
Environmental data
Ambient temp. (operation/storage) -40°C … +50°C/-40°C … +70°C
Protective circuit 6)
6) 2=polarity reversal protection, 3=short circuit protection for all outputs
2, 3
VDE safety class 7)
7) Rating voltage 250 VAC
II, all-insulated
Protection class 8)
8) In end position of the turning connector (turning connector engaged)
IP 67, IP 69K 9)
9) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives,
acids and bases are not part of the test
Environmentally tested acc. to ECOLAB
Standards applied IEC 60947-5-2
Certifications UL 508, CSA C22.2 No.14
Order guide
Designation Part no.
With M12 connector
and voltage output ODSL 8/V66-45-S12 50108363
and current output ODSL 8/C66-45-S12 50108364
Diagrams
Characteristic curve of switching
outputs:
AHysteresis
BSwitching point Q1 (teach point)
CSwitching point Q2 (teach point)
DMeasurement distance
ODSL 8
Remarks
Measurement time
depends on the reflectivity
of the measurement
object and on the mea-
surement mode.
Operate in accordance with
intended use!
This product is not a safety sensor
and is not intended as personnel
protection.
The product may only be put into
operation by competent persons.
Only use the product in accor-
dance with the intended use.