LumaCan™ Phase Cut Dimmer
Cat. No. DRDDP
INSTALLATION INSTRUCTIONSENGLISH
DI-002-DRDDP-00A-X3
WARNINGS
• TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE
AND TEST THAT POWER IS OFF BEFORE WIRING!
• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are unsure about any part of these instructions, consult an electrician.
• To avoid electrical overload, total connected lamp load shall not exceed output rating.
• This equipment permits more than one power supply output source.
• Do not mount near gas or electric heaters.
CAUTIONS
• Use this device with copper or copper clad wire only.
• For indoor applications only.
• Test all network cables for proper pin-out configuration prior to interconnecting devices and systems.
• If you are unsure about any part of these instructions, consult an electrician.
• Save these instructions.
Product Description
The GreenMAX™ DRC Phase Cut Dimmer provides dimming of phase control loads,
either forward or reverse phase, LumaCAN network connectivity, and full integration
into Leviton’s GreenMAX DRC system.
Installation
WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring!
Wiring Diagrams
2. Remove/add channel jumpers depending on configuration.
DI-002-DRDDP-00A-X3© 2018 Leviton Mfg. Co., Inc.
Before Installation
• Dimmer modules should be installed in a suitable DIN rail enclosure.
• All mains wiring should be done in accordance with local authority wiring regulations.
• Appropriate isolation shall be maintained between Line and Low Voltage cabling.
• For more information on network wiring, see the Leviton GreenMAX DRC Installation Guide
and training videos at www.Leviton.com.
• Confirm load type and amount is within product capabilities as not all load types are supported.
• Confirm Channel/Load requirements to plan for installation, when multiple channels are to be combined
for additional current capacity, refer to AMPlify feature for details.
1. Mount dimmer on DIN rail.
a. Line top of module against the back of the cabinet and
slide the module down onto rail.
b. Push module towards the rail.
c. Push up on mounting clip to lock module in place.
3. Wire “feeder” input to Line Input Terminal.
4. Connect Loads to Load Output Terminals.
5. Connect Network Wiring.
6. Power-up dimmer and confirm load operation using dimmer test
switches. Your Dimmer is now ready for network configuration.
Note: Ensure last node on network is terminated.
1 Channel (10A)
NEUTRAL LOAD OUT 1 LOAD OUT 2 LOAD OUT 3 LOAD OUT 4NEUTRAL NEUTRAL NEUTRAL NEUTRAL
EARTH
GND LINE IN
TEST
TEMP
NET
AUX. IN
A B
MODE 1 3 42
STATUS
Bus network cable
(CAT 6A or better)
Neutral Line In
Channel Jumper Channel Jumper Channel Jumper
Load 1
10A MAX
NEUTRAL LOAD OUT 1 LOAD OUT 2 LOAD OUT 3 LOAD OUT 4NEUTRAL NEUTRAL NEUTRAL NEUTRAL
EARTH
GND LINE IN
TEST
TEMP
NET
AUX. IN
A B
MODE 1 3 42
STATUS
Bus network cable
(CAT 6A or better)
Neutral Line In
Channel Jumper Channel Jumper Channel Jumper
Load 1
10A MAX
NEUTRAL LOAD OUT 1 LOAD OUT 2 LOAD OUT 3 LOAD OUT 4NEUTRAL NEUTRAL NEUTRAL NEUTRAL
EARTH
GND LINE IN
TEST
TEMP
NET
AUX. IN
A B
MODE 1 3 42
STATUS
Bus network cable
(CAT 6A or better)
Neutral Line In
Load 1
5.0A MAX
Load 2
5.0A MAX
Channel Jumper Channel Jumper
2 Channel (5A)
To remove
from DIN rail
DIN rail
NEUTRAL LOAD OUT 1 LOAD OUT 2 LOAD OUT 3 LOAD OUT 4NEUTRAL NEUTRAL NEUTRAL NEUTRAL
EARTH
GND LINE IN
TEST
TEMP
NET
AUX. IN
A B
MODE 1 3 42
STATUS
Bus network cable
(CAT 6A or better)
Load 1
2.5A MAX Neutral Line In
Load 2
7.5A MAX
Channel Jumper Channel Jumper
2 Channel (1x2.5A,1x7.5A)
NEUTRAL LOAD OUT 1 LOAD OUT 2 LOAD OUT 3 LOAD OUT 4NEUTRAL NEUTRAL NEUTRAL NEUTRAL
EARTH
GND LINE IN
TEST
TEMP
NET
AUX. IN
A B
MODE 1 3 42
STATUS
Bus network cable
(CAT 6A or better)
Neutral Line In Channel Jumper
Load 1
2.5A MAX
Load 2
2.5A MAX
Load 3
5.0A MAX
3 Channel (2x2.5A, 1x5A)
a.
c.
b.
NEUTRAL LOAD OUT 1 LOAD OUT 2 LOAD OUT 3 LOAD OUT 4NEUTRAL NEUTRAL NEUTRAL NEUTRAL
EARTH
GND LINE IN
TEST
TEMP
NET
AUX. IN
A B
MODE 1 3 42
STATUS
Bus network cable
(CAT 6A or better)
Neutral Line In
Load 1
2.5A MAX
Load 3
2.5A MAX
Load 2
2.5A MAX
Load 4
2.5A MAX
4 Channel (2.5A)
SPECIFICATIONS
Catalog No. DRDDP-A40 (4 Channel) DRDDP-A20 (2 Channel)
Input Voltage/Frequency 120-277VAC, 50/60Hz 120-277VAC, 50/60Hz
Max Input Current 10A 5A
Load Ratings
LED,CFL, Electronic Ballast,
Incandescent, Tungsten @ 120V
2.5A (300W)/Channel
(See channel ganging chart for additional details)
LED,CFL, Electronic Ballast,
Incandescent, Tungsten @ 277V
2.5A (693W)/Channel
(See channel ganging chart for additional details)
IP Rating / Enclosure IP20
Pollution Degree 2
UL Disconnection Type Type 1Y Action, Electronic Disconnection, Non-Airgap
UL Voltage Category 6,000V
Terminal Torque Rating,
Line & Low Voltage 0.37in-lbs (0.5Nm)
Network Connections (2) RJ-45, CAT6A or better for connection to LumaCAN
network. Termination provided via local termination plug.
Network Topology
• Daisy Chain, 1600’ Max between repeaters.
• Home-Run topology and network length up to 10,000’
can be achieved when using LumaCAN network repeaters
(Leviton # NPRPT)
• Maximum 110 nodes between repeaters
Maximum 250 nodes on a LumaCAN network
Operating Temperature
(In DIN rail cabinet) 0-60oC (32-140oF)
Storage Temperature -40-70oC
Certifications FCC Part 15 Class A
DI-002-DRDDP-00A-X3© 2018 Leviton Mfg. Co., Inc. For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only) www.leviton.com
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and
proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option. For details visit www.leviton.com or call 1-800-824-3005. This warranty
excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed impro perly or in an improper environment, overloaded, misused,
opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including
merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a
particular purpose, is limited to five years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment,
lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada should contact Leviton in writing at Leviton Manufacturing of Canada Ltd to the attention of the Quality Assurance Department,
165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9 or by telephone at 1 800 405-5320.
INDUSTRY CANADA COMPLIANCE STATEMENT:
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the device. IMPORTANT! Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate
this equipment. This Class A digital apparatus complies with Canadian CAN ICES-3(A)/NMB-3(A).
TRADEMARK DISCLAIMER: Use herein of third party trademarks, service marks, trade names, brand names and/or product names are for informational purposes only, are/may be the trademarks of their respective
owners; such use is not meant to imply afliation, sponsorship, or endorsement. Patents covering this Product, if any, can be found on Leviton.com/patents.
Interface
9. Indicator light - Displays device operating temperature status
a. TEMP indicator
- Green – Normal
- Amber – Warm
- Red flashing – Hot
- Red solid – Shutdown
b. NET indicator
- Blinks during TX/RX of network data
10. MODE LED Indicator & Button: Used to select and
display device operating modes. (see below)
11. Channel status 1, 2, 3, 4: Individual indicator for each channel.
a. Indicator intensity follows channel level
b. Alternates from 25%->50%->100%->0%
12. Channel button 1, 2, 3, 4: Individual channel status selector
TEST
TEMP
NET
MODE 1 3 42
STATUS
11
10
12
9
Configuration
Device can be programmed through the GreenMAX DRC System app when connected to a GreenMAX DRC room controller.
In applications where you are not using GreenMAX DRC room controllers, limited configuration capability is available from the front panel of the devices.
1. To enter program mode:
Press and hold for
approximately 5 seconds
until indicator turns red.
2. To toggle between
Phase Control and AMPlify setup,
press and release.
Red - Phase Control
Blue - AMPlify
TEST
TEMP
NET
MODE 1 3 42
STATUS
To toggle between Forward and Reverse Phase
Control, press and release the corresponding
channel button.
ON - Forward Phase Control
OFF - Reverse Phase Control
Phase Control Method Selection
TEST
TEMP
NET
MODE 1 3 42
STATUS
AMPlify Feature Mode Selection
Only a limited number of configurations are supported from the front
panel. Other configurations can be set from the GreenMAX DRC
system programming tools.
Channel LED indicators lights up to indicate that the channel is grouped
together. Press/Release the channel buttons to change the grouping.
Refer to chart below to see which LED Indicator combinations
correspond with each channel mode.
FCC COMPLIANCE STATEMENT:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Any changes or modifications not expressly approved by Leviton could void the user’s authority to operate this equipment.
1. Line In and Neutral: Common to all channels.
2. Load Out 1, 2, 3, 4: Connects to the load for each channel.
3. Neutral: Individual neutral for each channel.
4. Earth Ground: Common to all channels
5. LumaCan Address & Start Channel Assignment DIP Switches
6. Aux In A & B: Auxiliary active high (+24V) or dry contact input (for future use)
7. DIN Rail Mounting Clip
8. LumaCan: Network input and feedthrough RJ45
NEUTRAL LOAD OUT 1 LOAD OUT 2 LOAD OUT 3 LOAD OUT 4NEUTRAL NEUTRAL NEUTRAL NEUTRAL
EARTH
GND LINE IN
TEST
TEMP
NET
AUX. IN
A B
MODE 1 3 42
STATUS
Bus network cable
(CAT 6A or better)
3
8
6
5 7
2 2 1 1
4
2 2
3 3 3
LumaCAN Network Termination
LumaCAN Network Addressing
The last Node in a LumaCAN network must have the termination jumper/plug installed.Your unit ships with a termination plug
(P/N #LCTRM) installed into one of the RJ-45’s.
Set DIP switches 1-8 to the desired LumaCAN address.
A unique LumaCAN address ID must be set for each LumaCAN device. Valid node addresses are 1-250. If the node ID’s are
defined in your Contract Document, set to that address.
If not, ensure that the ID is unique for each device in the system. It’s helpful, although not required, that the location of each node
ID is documented for use by Leviton Field service during system commissioning.
To set the node ID, set the DIP switches to the desired ID following the process below. Several examples are provided.
a. If this device is at the end of the line, the jumper shall remain installed and the network cable shall be connected to the other
plug.
b. If this device will be in the middle of a network run, remove the plug and save for future use.
c. If the plug was removed but is at the end of the line, the termination plug must be reinstalled.
12345678
ON
1
2
4
8
16
32
64
128
Switch Values
ID Address Value = Sum of Switch Values
ID 86 = 2+4+16+64
12345678
ON
ID 2ID 1
12345678
ON
ID 3
12345678
ON
ID 4
12345678
ON
ID 5
12345678
ON
ID 6
12345678
ON
ID 38
12345678
ON
ID 86
FCC SUPPLIERS DECLARATION OF CONFORMITY:
Model DRDDP – LumaCAN Phase Cut Dimmer
Manufactured by: Leviton Manufacturing Inc. 201 N Service Rd, Melville, NY 11747
Phone: 800.323.8920
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
To perform a factory reset: Press and hold for approximately
20 seconds until indicator light flashes rapidly, then release.
The device will then revert to the factory default operation.
NOTE: Default operation is single channel mode.
AMPlify Feature
Two or more channels can be wired in parallel to AMPlify your load carrying
capacity.
In order to use this feature:
• Jumper must be installed between channels you want to combine.
• Software must be configured. Go to Leviton.com.
The chart to the right indicates the configurations and operating modes which
are supported:
Mode No. of
Channels
Channel 1
Capacity
Channel 2
Capacity
Channel 3
Capacity
Channel 4
Capacity
LED Indicators
1234
1* 1 10A Jumper to 1 Jumper to 2 Jumper to 3 ON ON ON ON
2A 2 2.5A 7.5A Jumper to 2 Jumper to 3 OFF ON ON ON
3 3 2.5A 2.5A 5A Jumper to 3 OFF OFF ON ON
4 4 2.5A 2.5A 2.5A 2.5A OFF OFF OFF OFF
The following mode is only configurable via GreenMAX DRC App
2B 2 5A Jumper to 1 5A Jumper to 3
* Default Mode from the factory is single (1) channel mode with jumpers installed between all four
channels. In this mode, the dimmer operates like a single channel dimmer with max capacity of 10A.
For other configuration, jumpers must be removed as per the chart above.

Other Leviton Dimmer manuals

Leviton Decora Illumatech IPI06-1L User manual

Leviton

Leviton Decora Illumatech IPI06-1L User manual

Leviton LumaCan DRDDP User manual

Leviton

Leviton LumaCan DRDDP User manual

Leviton NSI DS8 Operating instructions

Leviton

Leviton NSI DS8 Operating instructions

Leviton Decora Illumatech IPM06-1L User manual

Leviton

Leviton Decora Illumatech IPM06-1L User manual

Leviton Vizia RF RZM10-1L User manual

Leviton

Leviton Vizia RF RZM10-1L User manual

Leviton DDS 6000+ User manual

Leviton

Leviton DDS 6000+ User manual

Leviton VZX12-7L User manual

Leviton

Leviton VZX12-7L User manual

Leviton vizia rf + VRMX1-1L Quick start guide

Leviton

Leviton vizia rf + VRMX1-1L Quick start guide

Leviton ACI06-1L User manual

Leviton

Leviton ACI06-1L User manual

Leviton VZH08-1L User manual

Leviton

Leviton VZH08-1L User manual

Leviton DDS5300 Operating instructions

Leviton

Leviton DDS5300 Operating instructions

Leviton ACM06-1L User manual

Leviton

Leviton ACM06-1L User manual

Leviton a-2000 User manual

Leviton

Leviton a-2000 User manual

Leviton Toggle Touch TGM10-1L User manual

Leviton

Leviton Toggle Touch TGM10-1L User manual

Leviton I 24 Manual

Leviton

Leviton I 24 Manual

Leviton MRIDC User manual

Leviton

Leviton MRIDC User manual

Leviton 6631-L User manual

Leviton

Leviton 6631-L User manual

Leviton Decora Multi-Remote MSE0R-1 User manual

Leviton

Leviton Decora Multi-Remote MSE0R-1 User manual

Leviton D4DMX User manual

Leviton

Leviton D4DMX User manual

Leviton Toggle Touch TGI06-1L User manual

Leviton

Leviton Toggle Touch TGI06-1L User manual

Leviton Acenti ACH08 User manual

Leviton

Leviton Acenti ACH08 User manual

Leviton i 48e Manual

Leviton

Leviton i 48e Manual

Leviton DDS6000 Operating instructions

Leviton

Leviton DDS6000 Operating instructions

Leviton DDS6000 User manual

Leviton

Leviton DDS6000 User manual

Popular Dimmer manuals by other brands

Lutron Electronics Maestro Wireless MRF2-600M Quick start quide

Lutron Electronics

Lutron Electronics Maestro Wireless MRF2-600M Quick start quide

INSTEON SwitchLinc 2478D quick start guide

INSTEON

INSTEON SwitchLinc 2478D quick start guide

Elation RMD-620 user manual

Elation

Elation RMD-620 user manual

Robus RCRX200DS instruction manual

Robus

Robus RCRX200DS instruction manual

Oase InScenio Dimmer operating instructions

Oase

Oase InScenio Dimmer operating instructions

PXM PX314 user manual

PXM

PXM PX314 user manual

City Theatrical SHoW DMX Neo D4 user manual

City Theatrical

City Theatrical SHoW DMX Neo D4 user manual

Jula 015579 quick start guide

Jula

Jula 015579 quick start guide

Trust 300DM quick start guide

Trust

Trust 300DM quick start guide

DINUY RE KNX LE3 quick start guide

DINUY

DINUY RE KNX LE3 quick start guide

VOS IntelaVoice 98009 instruction manual

VOS

VOS IntelaVoice 98009 instruction manual

Jasco 28166 quick start guide

Jasco

Jasco 28166 quick start guide

Vimar Eikon 20136.1 quick start guide

Vimar

Vimar Eikon 20136.1 quick start guide

Aladdin M3 user manual

Aladdin

Aladdin M3 user manual

Ekinex KNX 90-230 Setup and installation guide

Ekinex

Ekinex KNX 90-230 Setup and installation guide

Chauvet COLORado 6 Quick reference guide

Chauvet

Chauvet COLORado 6 Quick reference guide

Aquatlantis tecatlantis EASY LED CONTROL user manual

Aquatlantis

Aquatlantis tecatlantis EASY LED CONTROL user manual

DMX4ALL DMX-LED-DIMMER X9HR+ user manual

DMX4ALL

DMX4ALL DMX-LED-DIMMER X9HR+ user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.