Luxul Xen XGS-1008 User manual

luxul.com
Simply Connected
User Guide
XGS-1008
Luxul Xen™
8-Port Gigabit Ethernet Switch
SWITCH
Use the XGS-1008 to:
Expand Your Home or Offi ce Network with 8-Ports
Future Proof Your Network with Gigabit Speeds
(10X Performance of Fast Ethernet)
Create a VLAN for Optimizing VoIP, Video, Security, or Gaming
Applications (requires XMS-1024)

User Guide
2© Copyright 2011 Luxul. All rights reserved. Trademarks & Registered Trademarks are property of respective holders.
8-PORT GIGABIT ETHERNET SWITCH
MODEL NUMBER: XGS-1008
USER GUIDE
© 2011 Luxul. All Rights Reserved.
No part of this publication may be modifi ed or adapted in any way, for any
purposes without permission in writing from Luxul. The material in this manual
is subject to change without notice. Luxul reserves the right to make changes to
any product to improve reliability, function, or design. No license is granted, either
expressly or by implication or otherwise under any Luxul intellectual property rights.
An implied license only exists for equipment, circuits and subsystems contained in
this or any Luxul product.
DOCUMENT CONVENTIONS
The following graphical alerts are used in this document to indicate notable situations:
NOTE: Tips, hints, or special requirements that you should take note of.
CAUTION: Care is required. Disregarding a caution can result in data
loss or equipment malfunction.
WARNING!: Indicates a condition or procedure that could result in
personal injury or equipment damage.

luxul.com | 357 South 670 West | Suite 160 | Lindon, UT 84042 | p: 801-822-5450 | f: 801-822-5460
luxul.com | 357 South 670 West | Suite 160 | Lindon, UT 84042 | p: 801-822-5450 | f: 801-822-5460
User Guide
3
CONTENTS
1: PRODUCT OVERVIEW 4
1.1 Product Introduction 4
1.2 XGS-1008 Features 4
1.3 Product Specifi cations 5
1.4 Package Contents 6
2: HARDWARE DESCRIPTION 6
2.1 Front Panel 6
2.2 LED Indicators 6
2.3 Rear Panel Layout 7
3. PREPARING FOR INSTALLATION 8
3.1 System Requirements 8
3.2 Installation Requirements 8
3.3 Before Connecting to the Network 8
4. XGS-1008 INSTALLATION 8
4.1 Connecting Devices 8
4.2 Connecting to a Router or Other Switch 9
5: REGULATORY COMPLIANCE 10
5.1 Health and Safety Recommendations 10
5.2 FCC Statement: 10
6: CONTACT LUXUL 11

User Guide
4© Copyright 2011 Luxul. All rights reserved. Trademarks & Registered Trademarks are property of respective holders.
1: PRODUCT OVERVIEW
1.1 Product Introduction
The XGS-1008 8-Port Desktop Gigabit Ethernet Switch is especially suited to
home and small-business networking. It provides eight 10/100/1000Mbps ports
with Auto-negotiation and Auto MDI/MDIX capability. All ports can be used for
ordinary network traffi c as well as for uplinks to connect with other networking
devices (i.e. routers, switches, etc.). The XGS-1008 provides 10X the performance
of a standard 10/100Mbps switch and can be a simple upgrade replacement for
resolving performance bottleneck issues associated with the use of legacy Ethernet
switch hardware. Each port within the XGS-1008 can deliver up to 2000Mbps in
full-duplex mode, making it an excellent choice of improving performance be-
tween devices on the local network. With easy XenConnect™ plug-and-play setup
and no network management you will benefi t from a seamless installation, whether
you are setting up a new network or upgrading from a legacy 10/100 switch.
1.2 XGS-1008 Features
Compliance with IEEE802.3, IEEE802.3u and IEEE802.3ab Ethernet standards,
supporting 10/100/1000 transfer modes.
Auto MDI/MDIX on each port
NWAY Auto-Negotiation functionality
Eight 10/100/1000Mbps RJ-45 ports
IEEE802.3x fl ow control for full-duplex and Backpressure fl ow control for
half-duplex
16Gbps backplane bandwidth and non-blocking wire speed forwarding
Store-and-forward switching method
8kb MAC address table and MAC address auto-learning/auto-aging
XenConnect “Plug and Play” Compatibility
Small footprint desktop design

luxul.com | 357 South 670 West | Suite 160 | Lindon, UT 84042 | p: 801-822-5450 | f: 801-822-5460
luxul.com | 357 South 670 West | Suite 160 | Lindon, UT 84042 | p: 801-822-5450 | f: 801-822-5460
User Guide
5
1.3 Product Specifi cations
Supported
Protocols and
Standards
IEEE 802.3 10Base-T Ethernet
IEEE 802.3u 100Base-TX Fast Ethernet
IEEE 802.3ab 1000Base-T Gigabit Ethernet
IEEE 802.3 NWay Auto-negotiation
IEEE 802.3x Flow Control
CSMA/CD
HTTP
ARP
DNS
ICMP
TCP/IP
Features Number of Ports: Eight 10/100/1000BASE-T
MAC Address Table: 8K
Switch Fabric: 16Gbps
Transmission Method: Store-and-forward
Auto uplink (MDI/MDI-X) detection and confi guration
MAC Address Learning /Auto-learning, Auto-aging
Packet Filtering/
Forwarding Rate
14880pps (10Mbps) per port
148800pps (100Mbps) per port
1488000pps (1000Mbps) per port
Network Data
Transfer Rate
Ethernet: 10Mbps (Half-duplex)
Ethernet: 20Mbps (Full-duplex)
Fast Ethernet: 100Mbps (Half-duplex)
Fast Ethernet: 200Mbps (Full-duplex)
Gigabit Ethernet: 1000Mbps (Half-duplex)
Gigabit Ethernet: 2000Mbps (Full-duplex)
Interface
Options
RJ-45:
10 Base-T: Cat.5 UTP /STP
100 Base-TX: Cat.5 UTP /STP
1000Base-T: Cat.5, Cat.5e or Cat.6 UTP/STP
Cable Recognition for Straight-through or Crossover Cables
Certifi cations FCC Class B, CE, RoHS
Led Per unit: Power
Per port: Link/Activity
DC Input DC 9V 600mA
Power
Consumption
10 Watts Maximum
Power Supply External Power Adapter
Operating
Temperature
32°F to 104°F
(0°C to 40°C)

User Guide
6© Copyright 2011 Luxul. All rights reserved. Trademarks & Registered Trademarks are property of respective holders.
Operating
Humidity
10% to 90%
(Non-condensing)
Dimensions W: 6.8” x D: 4.3” x H: 1.2”
(W: 172.72mm x D:109.22mm x H: 30.5mm)
Weight Item: 4.5 lbs (2.1Kg)
Packaging: 6 lbs (2.7Kg)
1.4 Package Contents
Please check the contents carefully after you open the packing:
XGS-1008 8-Port Gigabit Ethernet Switch
Power Adapter
Quick Install Guide
CD with User Documentation
If any of the listed items are missing or damaged, please contact the reseller from
whom you purchased the XGS-1008 for return/replacement.
2: HARDWARE DESCRIPTION
2.1 Front Panel
The front panel of the XGS-1008 includes 8 Link/Activity LED’s and one power LED.
Please refer to the detailed description of these indicators in Section 2.2 below.
876 5 4 3 2 1POWER8-Port Gigabit Ethernet Switch
XGS-1008 Front Panel View
2.2 LED Indicators
The LED indicators of the XGS-1008 include 1 Power indicator and 8 Link/Activity
indicators. These LED indicators show the operating status of the XGS-1008 and
each switch connection.
The following chart shows the LED indicators of the XGS-1008 along with an
explanation of the indicator’s properties:

luxul.com | 357 South 670 West | Suite 160 | Lindon, UT 84042 | p: 801-822-5450 | f: 801-822-5460
luxul.com | 357 South 670 West | Suite 160 | Lindon, UT 84042 | p: 801-822-5450 | f: 801-822-5460
User Guide
7
LED Color Status Description
Power Green ON This indicator lights up when the XGS-1008
is powered
— OFF If this indicator is not lit, please check the
DC power supply to ensure proper connec-
tion to the outlet and the XGS-1008.
Link/
Activity
Green ON Indicates the XGS-1008 is connected at
1000Mbps.
Blinking Indicates the XGS-1008 is transmitting/
receiving data packets at 1000Mbps.
Orange ON Indicates the XGS-1008 is connected at
10/100Mbps.
Blinking Indicates the XGS-1008 is transmitting/
receiving data packets at 10/100Mbps.
— OFF Indicates the port is not connected to a
device.
2.3 Rear Panel Layout
The Rear Panel of the XGS-1008 includes 8 10/100/1000Mbps RJ-45 Ethernet ports
and one DC power port used for DC power input.
12345678 POWER
XGS-1008 Rear Panel View
CAUTION: Please use the included power supply. If a different power
supply is used, it could damage the XGS-1008

User Guide
8© Copyright 2011 Luxul. All rights reserved. Trademarks & Registered Trademarks are property of respective holders.
3. PREPARING FOR INSTALLATION
3.1 System Requirements
Ethernet Cables to connect the XGS-1008 to Ethernet enabled devices
Power should be AC 100-240V~ 0.1A(Max) 50/60Hz.
3.2 Installation Requirements
Install the XGS-1008 in a stable/safe place to avoid any possible damage
Inspect the AC power cord to ensure that it is correctly connected and
undamaged
To avoid electric shock, DO NOT open the XGS-1008 housing (no user service-
able parts inside). Opening the XGS-1008 will void your warranty.
It is recommended that the Grounding connection to the outlet is functioning
properly and the XGS-1008 is positioned away from direct sun light
Ensure there is suffi cient space around the XGS-1008 for proper ventilation and
heat dissipation. It is recommended to have at least 4-6 inches around all sides.
3.3 Before Connecting to the Network
Before connecting the XGS-1008 to the network, please check the following:
Determine placement location. Do not place any heavy articles on the XGS-1008.
Ensure there is adequate space for proper heat dissipation and ventilation around
the XGS-1008.
Power socket should be within 4 feet of the XGS-1008.
Check power adapter to confi rm safe and secure connection.
4. XGS-1008 INSTALLATION
4.1 Connecting Devices
Use standard Ethernet CAT5, CAT5e or CAT6 cable to connect the XGS-1008 to
a device as described below (CAT6 must be used in order to achieve full Gigabit
bandwidth). The XGS-1008 will automatically adjust to the characteristics (speed/
duplex) of the device to which it is connected.

luxul.com | 357 South 670 West | Suite 160 | Lindon, UT 84042 | p: 801-822-5450 | f: 801-822-5460
luxul.com | 357 South 670 West | Suite 160 | Lindon, UT 84042 | p: 801-822-5450 | f: 801-822-5460
User Guide
9
12345678 POWER
Connecting the XGS-1008 to a Device
When a device is properly connected, the Link/Activity LEDs for each port lights
up green/orange. Please refer to the LED Indicators section for defi nitions and
troubleshooting.
4.2 Connecting to a Router or Other Switch
12345678 POWER
XBR-2300
Enterprise Dual-WAN Router
POWER
100M
RESET
SYS
1 2 1 2 3
LANWAN
LAN
WAN
12123
Internet
Connecting the XGS-1008 to a Router or Switch
When a device is properly connected, the Link/Activity LEDs for each port light
up green/orange. Please refer to the LED Indicators section for defi nitions and
troubleshooting.

User Guide
10 © Copyright 2011 Luxul. All rights reserved. Trademarks & Registered Trademarks are property of respective holders.
5: REGULATORY COMPLIANCE
This device is approved under the Luxul brand and designed to comply for use spe-
cifi cally with other approved Luxul devices. This device is designed to be compliant
with rules and regulations in locations where they are sold and will be labeled as
required. Any changes or modifi cations to Luxul equipment, not expressly ap-
proved by Luxul, could void the user’s authority to operate the equipment. This
Luxul device when used in conjunction with the approved Luxul Models should be
professionally installed and the Radio Frequency Output Power will not exceed the
maximum allowable limit for those countries that have regulatory approval.
5.1 Health and Safety Recommendations
Warnings for the use of Wireless Devices: Please observe all warning notices with
regard to the usage of wireless devices
Potentially Hazardous Atmospheres: You are reminded of the need to observe
restrictions on the use of radio devices in fuel depots, chemical plants etc. and areas
where the air contains chemicals or particles (such as grain, dust, or metal powders).
Safety in Hospitals: Wireless devices transmit radio frequency energy and may
affect medical electrical equipment. When installed adjacent to other equipment,
it is advised to verify that the adjacent equipment is not adversely affected.
Power Supply: Use only a Luxul approved power supply output rated at 9VDC and
minimum 0.6A. The power supply shall be Listed to UL/CSA 60950-1; and certifi ed
to IEC60950-1 and EN60950-1 with SELV outputs. The device can also be powered
from a compliant POE source. Use of alternative power supply will invalidate any
approval given to this device and may be dangerous.
5.2 FCC Statement:
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential instal-
lation. This equipment uses and can radiate radio frequency energy, and if not
installed and used in accordance with the instructions may cause harmful interfer-
ence to radio communications. However; there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference
by one or more of the following measures:

luxul.com | 357 South 670 West | Suite 160 | Lindon, UT 84042 | p: 801-822-5450 | f: 801-822-5460
luxul.com | 357 South 670 West | Suite 160 | Lindon, UT 84042 | p: 801-822-5450 | f: 801-822-5460
User Guide
11
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
6: CONTACT LUXUL
For sales questions
please contact our
Sales Department
P: (801) 822-5450
If you experience any
problems, please contact
Technical Support
P: (801) 822-5450

LUX-UG-XGS-1008
092111109
357 South 670 West |Suite 160 | Lindon, UT 84042
p: 801-822-5450 | f: 801-822-5460
Information on this document supersedes all previous versions.
Products and documents subject to change without notice.
Products may be discontinued without notice.
luxul.com
Other manuals for Xen XGS-1008
4
Table of contents
Other Luxul Switch manuals

Luxul
Luxul XMS-2624P User manual

Luxul
Luxul XMS-1008P User manual

Luxul
Luxul Xen XGS-1008 User manual

Luxul
Luxul AMS-1816P User manual

Luxul
Luxul XFS-1084P User manual

Luxul
Luxul Xen XGS-1008 User manual

Luxul
Luxul XGS-1024 User manual

Luxul
Luxul XMS-1024P User manual

Luxul
Luxul XFS-1816P User manual

Luxul
Luxul XMS-1008P User manual

Luxul
Luxul XMS-1010P-E User manual

Luxul
Luxul XMS-2624P User manual

Luxul
Luxul AGS-1016 User manual

Luxul
Luxul Xen XGS-1008 User manual

Luxul
Luxul XMS-7048P User manual

Luxul
Luxul AMS-2616P User manual

Luxul
Luxul AGS-1008M User manual

Luxul
Luxul AMS-1208P User manual

Luxul
Luxul XGS-1024S User manual

Luxul
Luxul XGS-1005 User manual