M8BS2-081
P. 1 / 3EM-5479-1 Rev.3
BEFORE USE ....
Thank you for choosing M-System. Before use, check the
package you received as below.
If you have any problems or questions with the product,
please contact M-System's Sales Office or representatives.
■ PACKAGE INCLUDES:
Installation base.......................................................(1)
■MODEL NO.
Confirm that the model number described on the product is
exactly what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when you
use this product, including installation, connection and basic
maintenance procedures.
POINTS OF CAUTION
■ CONFORMITY WITH EC DIRECTIVES
• This equipment is suitable for use in a Pollution Degree 
2 environment and in Installation Category II, with the
maximum operating voltage 300V.
Basic insulation is maintained between the input and output.
Prior to installation, check that the insulation class of this 
unit satisfies the system requirements.
• The equipment must be mounted inside a panel.
• The  equipment  must be installed such that  appropriate 
clearance and creepage distances are maintained to conform
to CE requirements. Failure to observe these requirements
may invalidate the CE conformity.
■ POWER INPUT RATINGS
•  Power  input  ratings  are  specied  by  the  model  number 
suffix code. Check the power input voltage for the unit on
the specification label.
AC power: 100 – 240V AC rating: 85 – 264V, 47 – 63 Hz,
130VA min.
DC power:  24 V DC rating: 24V ±10%, 2,5A min.
■ ENVIRONMENT
• Indoor use
• When  heavy  dust  or  metal  particles  are  present  in  the 
air, install the installation base inside proper housing and
ventilate it.
• Do not install the base where it is subjected to continuous 
vibration.  Do not apply physical impact to the unit.
• Environmental temperature must be within 0 to 55°C or 32 
to 131°F (0 to 50°C or 32 to 122°F for AC power) with relative 
humidity within 30 to 90% RH (30 to 85% RH for AC Power)  
in order to ensure adequate life span and operation.
•  Be  sure  that  the  ventilation  slits  are  not  covered  with 
cables, etc.
■ WIRING
• Do not install cables (power supply, input and output) close 
to noise sources (relay drive cable, high frequency line, etc.).
• Do not bind these cables together with those in which noises 
are present.  Do not install them in the same duct.
■ AND ....
• The unit is designed to function as soon as power is supplied, 
however, a warm up for 10 minutes is required for satisfying
complete performance described in the data sheet.
COMPONENT IDENTIFICATION
■ REAR VIEW
INSTALLATION BASE
(for Network interface) MODEL
M8BS2-081
INSTRUCTION MANUAL
MOUNTING REQUIREMENTS mm (inch)
310 (12.20)
4–M5 SCREW
50 (1.97)
Specifications
M8BS2-081
P. 2 / 3EM-5479-1 Rev.3
TERMINAL CONNECTIONS
Connect the unit referring the drawings below and the connection diagrams in the following page.
■EXTERNAL DIMENSIONS mm (inch)
• M8BS2-081-M2
1 2 345 6 78
3
4
5
2
1
PWR1
CH1 CH8
CDCDCDCDCDCDCDCD
ABABABABABABABAB
16–M3.5
OUTPUT TERMINALS
+–+–+–+–+–+–+–+–
100 (3.94)
50 (1.97)
290 (11.42)
310 (12.20)
330 (13.00)
156 (6.14)
132 (5.20) 26 (1.02) min.
AC POWER UNIT
5–M4 POWER
TERMINALS
8.5(.34)
CH8CH1
32–M3.5 INPUT TERMINALS
17 (.67)
CT PROTECTOR (CTR)
7.2(.28)
7.3 (.29)
• M8BS2-081-R
1 2 345 6 78
CH1 CH8
CDCDCDCDCDCDCDCD
ABABABABABABABAB
3–M3.5 POWER
TERMINALS
123
92 (3.62)
7.2(.28)
16–M3.5
OUTPUT TERMINALS
POWER LED
+–+–+–+–+–+–+–+–
8.6 (.34)
100 (3.94)
50 (1.97)
290 (11.42)
310 (12.20)
330 (13.00)
132 (5.20) 26 (1.02) min.
CH8CH1
32–M3.5 INPUT TERMINALS
17 (.67)
CT PROTECTOR (CTR)
7.3 (.29)
M8BS2-081
P. 3 / 3EM-5479-1 Rev.3
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2)  Power  input  voltage:    Check  voltage  across  the  power 
terminals.
3) Installation & environment
MAINTENANCE
Power units' standard life is expected for 10 years with aver-
age ambient temperature 35°C (95°F) and 1.0A load.  Contact 
M-System for use in extremely different conditions.
■
HOW TO REPLACETHE POWER UNIT (power suffix code: M2)
1)  Prepare Power Unit (switching regulator) model HDC10.
2)  Turn off the power supply connected to the Power Unit.
3)  Remove  the  wire  binding  and  wiring  connected  to  the 
terminal 1 – 2 and 4 – 5.
4) Loosen and remove the mounting screws A(4 places).
5)  Detach the Power Unit from the Installation Base.
6)  Attach the new Power Unit to the Installation Base and 
tighten the screws in reverse order as explained above.
A
B
C
D
Ch.1
INPUT
A
B
C
D
Ch.8
INPUT
+
–
+
–
AC
POWER
UNIT
4
5
FG
3
U
V
AC POWER
FG
3
2
1
A
B
C
D
Ch.1
INPUT
A
B
C
D
Ch.8
INPUT
+
–
+
–
■ DC Power Supply ■ AC Power Supply
OUTPUT 2
OUTPUT 2
Ch.1
OUTPUT
Ch.8
OUTPUT
OUTPUT 2
OUTPUT 2
Ch.1
OUTPUT
Ch.8
OUTPUT
POWER
+
-
A
B
C
D
Ch.1
INPUT
A
B
C
D
Ch.8
INPUT
+
–
+
–
AC
POWER
UNIT
4
5
FG
3
U
V
AC POWER
FG
3
2
1
A
B
C
D
Ch.1
INPUT
A
B
C
D
Ch.8
INPUT
+
–
+
–
■ DC Power Supply ■ AC Power Supply
OUTPUT 2
OUTPUT 2
Ch.1
OUTPUT
Ch.8
OUTPUT
OUTPUT 2
OUTPUT 2
Ch.1
OUTPUT
Ch.8
OUTPUT
POWER
+
-
■ CONNECTION DIAGRAM
M-SYSTEM WARRANTY
M-System warrants such new M-System product which it manufactures to be free from defects in materials and workmanship during the 36-month period following the date that such
product was originally purchased if such product has been used under normal operating conditions and properly maintained, M-System’s sole liability, and purchaser’s exclusive
remedies, under this warranty are, at M-System’s option, the repair, replacement or refund of the purchase price of any M-System product which is defective under the terms of this
warranty. To submit a claim under this warranty, the purchaser must return, at its expense, the defective M-System product to the below address together with a copy of its original
sales invoice.
THIS IS THE ONLY WARRANTY APPLICABLE TO M-SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. M-SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR
SPECIAL DAMAGES OF ANY KIND WHATSOEVER.
M-System Co., Ltd., 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN, Phone: (06) 6659-8201, Fax: (06) 6659-8510, E-mail: info@m-system.co.jp
3
4
5
2
1
V.ADJ
AA
A
A
A
1
2
3
4
5
: Mounting screws with
washer, M3 x 6 (4 pls.)
: 24V DC (+)
: 24V DC (–)
: FG
: AC power input (U)
: AC power input (V)

Other M-system Controllers manuals

M-system EAR70 User manual

M-system

M-system EAR70 User manual

M-system SC100 Series User manual

M-system

M-system SC100 Series User manual

M-system MSP4C User manual

M-system

M-system MSP4C User manual

M-system 18PP User manual

M-system

M-system 18PP User manual

M-system MSP10 User manual

M-system

M-system MSP10 User manual

M-system M8PP User manual

M-system

M-system M8PP User manual

M-system MSP40 User manual

M-system

M-system MSP40 User manual

M-system SC200 Series User manual

M-system

M-system SC200 Series User manual

M-system PSN1 User manual

M-system

M-system PSN1 User manual

M-system MRP4 User manual

M-system

M-system MRP4 User manual

M-system SC100 Series Instructions for use

M-system

M-system SC100 Series Instructions for use

M-system SC200W User manual

M-system

M-system SC200W User manual

M-system PSP10 User manual

M-system

M-system PSP10 User manual

M-system MSP4 User manual

M-system

M-system MSP4 User manual

M-system M8BS2-081 User manual

M-system

M-system M8BS2-081 User manual

M-system MRP10 User manual

M-system

M-system MRP10 User manual

M-system MSP5 User manual

M-system

M-system MSP5 User manual

M-system SC100 Series User manual

M-system

M-system SC100 Series User manual

Popular Controllers manuals by other brands

KBR multicomp 4D6-ESBSDS-1V1C6RO Operating instructions, technical parameters

KBR

KBR multicomp 4D6-ESBSDS-1V1C6RO Operating instructions, technical parameters

S&P RMB quick start guide

S&P

S&P RMB quick start guide

Elster MR HP20 operating instructions

Elster

Elster MR HP20 operating instructions

Broadcom MegaRAID SAS 9380-8i8e Quick installation guide

Broadcom

Broadcom MegaRAID SAS 9380-8i8e Quick installation guide

FD QYJ-10KPa manual

FD

FD QYJ-10KPa manual

Steinberg CMC Series Operation manual

Steinberg

Steinberg CMC Series Operation manual

Omron ZW-7000 Series instruction sheet

Omron

Omron ZW-7000 Series instruction sheet

Emerson Digitax ST user guide

Emerson

Emerson Digitax ST user guide

PROTRONIX UR10-AIR user manual

PROTRONIX

PROTRONIX UR10-AIR user manual

Danfoss EKC 331 instructions

Danfoss

Danfoss EKC 331 instructions

RLE Technologies SeaHawk LD310 quick start guide

RLE Technologies

RLE Technologies SeaHawk LD310 quick start guide

BioBrite SunRise instructions

BioBrite

BioBrite SunRise instructions

Wulfsberg C-5000 installation manual

Wulfsberg

Wulfsberg C-5000 installation manual

Sawo SAU-PC-V2 manual

Sawo

Sawo SAU-PC-V2 manual

SOMFY Smoove UNO io installation guide

SOMFY

SOMFY Smoove UNO io installation guide

Ruida Technology RDV3040-PCI Operation manual

Ruida Technology

Ruida Technology RDV3040-PCI Operation manual

TemperZone SAT-3 quick start guide

TemperZone

TemperZone SAT-3 quick start guide

Omron SYSMAC CPM1 Operation manual

Omron

Omron SYSMAC CPM1 Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.