manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. Controllers
  8. •
  9. M-system M8BS2-081 User manual

M-system M8BS2-081 User manual

Other M-system Controllers manuals

M-system MRP10 User manual

M-system

M-system MRP10 User manual

M-system M8PP User manual

M-system

M-system M8PP User manual

M-system SC200W User manual

M-system

M-system SC200W User manual

M-system MSP40 User manual

M-system

M-system MSP40 User manual

M-system 18PP User manual

M-system

M-system 18PP User manual

M-system MRP4 User manual

M-system

M-system MRP4 User manual

M-system EAR70 User manual

M-system

M-system EAR70 User manual

M-system SC100 Series User manual

M-system

M-system SC100 Series User manual

M-system MSP10 User manual

M-system

M-system MSP10 User manual

M-system SC100 Series User manual

M-system

M-system SC100 Series User manual

M-system SC200 Series User manual

M-system

M-system SC200 Series User manual

M-system SC100 Series Instructions for use

M-system

M-system SC100 Series Instructions for use

M-system PSN1 User manual

M-system

M-system PSN1 User manual

M-system MSP4 User manual

M-system

M-system MSP4 User manual

M-system MSP4C User manual

M-system

M-system MSP4C User manual

M-system PSP10 User manual

M-system

M-system PSP10 User manual

M-system MSP5 User manual

M-system

M-system MSP5 User manual

M-system M8BS2-081 User manual

M-system

M-system M8BS2-081 User manual

Popular Controllers manuals by other brands

Sunricher SR-ZV9003T3-RGBW-US Installation

Sunricher

Sunricher SR-ZV9003T3-RGBW-US Installation

Ksenia intro Installation and configuration manual

Ksenia

Ksenia intro Installation and configuration manual

Inovance CAN200 Series manual

Inovance

Inovance CAN200 Series manual

Gauzy LC6 FLEX Controller Installation and operation guide

Gauzy

Gauzy LC6 FLEX Controller Installation and operation guide

Viking SLP-1 Technical practice

Viking

Viking SLP-1 Technical practice

CKD KBX-30E-U Series instruction manual

CKD

CKD KBX-30E-U Series instruction manual

Sharp Energy Sun Flux User manual & installation guide

Sharp Energy

Sharp Energy Sun Flux User manual & installation guide

Yamaha RCX40 user manual

Yamaha

Yamaha RCX40 user manual

AB Quality PowerFlex 400 Frames D-H Service bulletin

AB Quality

AB Quality PowerFlex 400 Frames D-H Service bulletin

Yamaha MJC8 owner's manual

Yamaha

Yamaha MJC8 owner's manual

AL-KO ATC operating instructions

AL-KO

AL-KO ATC operating instructions

Savant SmartControl 2 Deployment guide

Savant

Savant SmartControl 2 Deployment guide

GameSir T3S user manual

GameSir

GameSir T3S user manual

Kostal inveor operating manual

Kostal

Kostal inveor operating manual

Emerson Yarway 20-55 Operating and safety instructions

Emerson

Emerson Yarway 20-55 Operating and safety instructions

CoCo ACM-LV24 Quick installation guide

CoCo

CoCo ACM-LV24 Quick installation guide

Brooks SLA5810/20 Installation and operation manual

Brooks

Brooks SLA5810/20 Installation and operation manual

SIGMA TEK SR 011 Technical manual

SIGMA TEK

SIGMA TEK SR 011 Technical manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-5479-1 Rev.6 P. 1 / 3
INSTRUCTION MANUAL
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Installation base ................................................................ (1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■CONFORMITY WITH EU DIRECTIVES
• This equipment is suitable for use in a Pollution Degree
2 environment and in Installation Category II, with the
maximum operating voltage 300V. Basic insulation is
maintained between the input and output. Prior to in-
stallation, check that the insulation class of this unit sat-
isfies the system requirements.
• The equipment must be mounted inside a panel.
• Altitude up to 2000 meters.
• The equipment must be installed such that appropriate
clearance and creepage distances are maintained to con-
form to CE requirements. Failure to observe these re-
quirements may invalidate the CE conformity.
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
100 – 240V AC rating: 85 – 264V, 47 – 63 Hz, ≥ 130VA
24V DC rating: 24V ±10%, ≥ 2.5A
■GENERAL PRECAUTIONS
• Before you remove the unit from the base or mount it,
turn off the power supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the installation base inside proper housing and
ventilate it.
• Do not install the base where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within 0 to 55°C or
32 to 131°F (0 to 50°C or 32 to 122°F for AC power) with
relative humidity within 30 to 90% RH (30 to 85% RH
for AC Power) in order to ensure adequate life span and
operation.
• Be sure that the ventilation slits are not covered with ca-
bles, etc.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
■REAR VIEW
Specifications
MOUNTING REQUIREMENTS unit: mm (inch)
300 (11.81)
4–M5 SCREW
50 (1.97)
INSTALLATION BASE
(8 positions, input, for network interface) MODEL
M8BS2-081
M8BS2-081
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-5479-1 Rev.6 P. 2 / 3
TERMINAL CONNECTIONS
Connect the unit as in the diagrams below.
■EXTERNAL DIMENSIONS unit: mm (inch)
• M8BS2-081-M2
1 2 345 6 78
CH1 CH8
CDCDCDCDCDCDCDCD
ABABABABABABABAB
16–M3.5
OUTPUT TERMINALS
+–+–+–+–+–+–+–+–
100 (3.94)
50 (1.97)
280 (11.02)
300 (11.81)
320 (12.60)
132 (5.20) 26 (1.02) min.
AC POWER UNIT
CH8CH1
32–M3.5 INPUT TERMINALS
17 (.67)
7.2(.28)
7.3 (.29)
*1. Included with M8CTx.
CT PROTECTOR (CTR)
*1
5–M3.5 POWER
TERMINALS
6.6 (.26)
156 (6.14)
3
4
5
2
1
V.ADJ
• M8BS2-081-R
1 2 345 6 78
CH1 CH8
CDCDCDCDCDCDCDCD
ABABABABABABABAB
3–M3.5 POWER
TERMINALS
123
92 (3.62)
7.2(.28)
16–M3.5
OUTPUT TERMINALS
POWER LED
+–+–+–+–+–+–+–+–
8.6 (.34)
100 (3.94)
50 (1.97)
280 (11.02)
300 (11.81)
320 (12.60)
132 (5.20) 26 (1.02) min.
CH8CH1
32–M3.5 INPUT TERMINALS
17 (.67)
7.3 (.29)
*1. Included with M8CTx.
CT PROTECTOR (CTR)
*1
M8BS2-081
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-5479-1 Rev.6 P. 3 / 3
■CONNECTION DIAGRAM
A
B
C
D
Ch.1
INPUT
A
B
C
D
Ch.8
INPUT
+
–
+
–
AC
POWER
UNIT
4
5
FG
3
U
V
AC POWER
FG
3
2
1
A
B
C
D
Ch.1
INPUT
A
B
C
D
Ch.8
INPUT
+
–
+
–
■ DC Power Supply ■ AC Power Supply
OUTPUT 2
OUTPUT 2
Ch.1
OUTPUT
Ch.8
OUTPUT
OUTPUT 2
OUTPUT 2
Ch.1
OUTPUT
Ch.8
OUTPUT
POWER
+
-
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Power input voltage: Check voltage across the power ter-
minals.
3) Installation & environment
MAINTENANCE
Power units’ standard life is expected for 10 years with
average ambient temperature 35°C (95°F) and 1.0A load.
Contact M-System for use in extremely different conditions.
■HOW TO REPLACETHE POWER UNIT (power input code: M2)
1) Prepare Power Unit (switching regulator) model HDC10.
2) Turn off the power supply connected to the Power Unit.
3) Remove the wire binding and wiring connected to the ter-
minal 1 – 2 and 4 – 5.
4) Loosen and remove the mounting screws A (4 places).
5) Detach the Power Unit from the Installation Base.
6) Attach the new Power Unit to the Installation Base and
tighten the screws in reverse order as explained above.
Note: For questions on products purchased before 2009, please
contact M-System.
A: Mounting screws with
washer, M3 x 6 (4 pls.)
1: 24 V DC (+)
2: 24 V DC (-)
3: FG
4: AC power input (U)
5: AC power input (V)
3
4
5
2
1
V.ADJ
AA
A
A