manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. Transmitter
  8. •
  9. M-system M5PT User manual

M-system M5PT User manual

EM-2488 Rev.6 P. 1 / 2
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
INSTRUCTION MANUAL
PT TRANSMITTER MODEL M5PT
BEFORE USE ....
Thank you for choosing us. Before use, please check con-
tents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact our sales office or representatives.
■PACKAGE INCLUDES:
Signal conditioner ...............................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
85 – 264V AC rating: 85 – 264V, 47 – 66 Hz, approx. 2 – 3VA
24V DC rating: 24V ±10%, approx. 2W
■GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -5 to +55°C
(23 to 131°F) with relative humidity within 0 to 90% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
• Install lightning surge protectors for those wires connect-
ed to remote locations. For 24V DC power supply line,
choose a surge protector with its maximum surge volt-
age 40V or less between lines. Recommended model:
MDP-D24.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
Specifications Power LED
Terminal Cover
Zero Adj.
Span Adj.
Body
INSTALLATION
Set the unit so that its DIN rail adapter is at the bottom.
■MOUNTING THE UNIT ON A DIN RAIL
A)Hang the upper hook at the rear side of unit on the DIN
rail.
B)Push in the lower in keeping pressing the unit to the DIN
rail.
A
B
DIN Rail
■REMOVING THE UNIT
A)Push down the DIN rail adaptor using a minus screw-
driver.
B)Pull out the lower part of the unit.
C)Remove the upper part from the DIN rail.
A
C
B
Spring Loaded
DIN Rail Adaptor
M5PT
EM-2488 Rev.6 P. 2 / 2
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the
connection diagram on the front of the unit.
■EXTERNAL DIMENSIONS unit: mm (inch)
94 (3.70)3 (.12)
25 (.98) 41 (1.61) [3.3 (.13)]
• When mounting, no extra space is needed between units.
DIN RAIL
35mm wide
8–M3.5 SCREW
7.3 (.29)
12
34
56
78
■CONNECTION DIAGRAM
+
–
OUTPUT
5
6
3
4
V
U
v
u
FUSE VT
LOAD
SOURCE
8
7U(+)
V(–)
POWER
(V)
(±)
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.8 N·m
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Power input voltage: Check voltage across the terminal
7 – 8 with a multimeter.
3) Input: Check that the input signal is within 5 – 120% of
the full-scale.
4) Output: Check that the load resistance meets the de-
scribed specifications.
ADJUSTMENT PROCEDURE
This unit is calibrated at the factory to meet the ordered
specifications, therefore you usually do not need any cali-
bration.
For matching the signal to a receiving instrument or in case
of regular calibration, adjust the output as explained in the
following.
■HOW TO CALIBRATE THE OUTPUT SIGNAL
Use a signal source and measuring instruments of sufficient
accuracy level. Turn the power supply on and warm up for
more than 10 minutes.
1) ZERO: Apply 10% input and adjust output to 10%.
2) SPAN: Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 10% input.
4) When ZERO value is changed, repeat the above proce-
dure 1) – 3).
MAINTENANCE
Regular calibration procedure is explained below:
■CALIBRATION
Warm up the unit for at least 10 minutes. Apply 10%, 25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accu-
racy described in the data sheet. When the output is out of
tolerance, recalibrate the unit according to the “ADJUST-
MENT PROCEDURE” explained earlier.
LIGHTNING SURGE PROTECTION
We offer a series of lightning surge protector for protec-
tion against induced lightning surges. Please contact us to
choose appropriate models.

Other M-system Transmitter manuals

M-system F2VF User manual

M-system

M-system F2VF User manual

M-system Mini-M M2RT User manual

M-system

M-system Mini-M M2RT User manual

M-system M2VF User manual

M-system

M-system M2VF User manual

M-system W5LCS User manual

M-system

M-system W5LCS User manual

M-system JR User manual

M-system

M-system JR User manual

M-system Mini-M M2RTS User manual

M-system

M-system Mini-M M2RTS User manual

M-system 10SP User manual

M-system

M-system 10SP User manual

M-system B3HU2 User manual

M-system

M-system B3HU2 User manual

M-system M6DXU User manual

M-system

M-system M6DXU User manual

M-system 10PA User manual

M-system

M-system 10PA User manual

M-system 6PA User manual

M-system

M-system 6PA User manual

M-system M3LR User manual

M-system

M-system M3LR User manual

M-system B5VS User manual

M-system

M-system B5VS User manual

M-system 27RS User manual

M-system

M-system 27RS User manual

M-system 6LC User manual

M-system

M-system 6LC User manual

M-system M3SXR User manual

M-system

M-system M3SXR User manual

M-system 10VF2 User manual

M-system

M-system 10VF2 User manual

M-system M3LT User manual

M-system

M-system M3LT User manual

M-system W2XT User manual

M-system

M-system W2XT User manual

M-system Mini-M Series User manual

M-system

M-system Mini-M Series User manual

M-system 6BLC User manual

M-system

M-system 6BLC User manual

M-system Mini-M M2DU User manual

M-system

M-system Mini-M M2DU User manual

M-system MXT User manual

M-system

M-system MXT User manual

M-system M5XTR User manual

M-system

M-system M5XTR User manual

Popular Transmitter manuals by other brands

FlowLine EchoPod UG06 Series quick start

FlowLine

FlowLine EchoPod UG06 Series quick start

Tri-Tronics Sport 50 G2 manual

Tri-Tronics

Tri-Tronics Sport 50 G2 manual

Scosche IPBTT manual

Scosche

Scosche IPBTT manual

Jobsite IR-E2 datasheet

Jobsite

Jobsite IR-E2 datasheet

BBV Tx1000 installation guide

BBV

BBV Tx1000 installation guide

Sony DWT-B01 operating instructions

Sony

Sony DWT-B01 operating instructions

Westlock DS operating manual

Westlock

Westlock DS operating manual

Transistor Lynx Door Transmitter manual

Transistor

Transistor Lynx Door Transmitter manual

Honeywell XYR 5000 Series user manual

Honeywell

Honeywell XYR 5000 Series user manual

Endress+Hauser Proline Prosonic Flow 93 operating instructions

Endress+Hauser

Endress+Hauser Proline Prosonic Flow 93 operating instructions

Emerson Rosemount 5600 Series Reference manual

Emerson

Emerson Rosemount 5600 Series Reference manual

Community Controls Stinger manual

Community Controls

Community Controls Stinger manual

CYP PU-USB2-KIT Operation manual

CYP

CYP PU-USB2-KIT Operation manual

Chamberlain 959CB owner's manual

Chamberlain

Chamberlain 959CB owner's manual

Status Instruments SEM1605/P user guide

Status Instruments

Status Instruments SEM1605/P user guide

nedis CATR121BK quick start guide

nedis

nedis CATR121BK quick start guide

TURBO RACING 91805G-VT instruction manual

TURBO RACING

TURBO RACING 91805G-VT instruction manual

Nautel NX200 Installation and operation manual

Nautel

Nautel NX200 Installation and operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.