manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MadgeTech
  6. •
  7. Data Logger
  8. •
  9. MadgeTech PRTC110 User manual

MadgeTech PRTC110 User manual

PRTC110
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE,
FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE. BATTERY MAY
LEAK OR EXPLODE IF HEATED ABOVE 80 °C (176 °F).
Specifications subject to change.
See MadgeTech’s terms and conditions
PRTC110
Differential Pressure and Thermocouple
Temperature Data Logger
Description PRTC110
Internal Channel Temperature Sensor Semiconductor
Internal Channel Temperature Range -20 °C to +80 °C (-4 °F to +176 °F)
Internal Channel Temperature Resolution 0.1 °C (0.18 °F)
Internal Channel Temperature Accuracy +0.5 °C (+0.9 °F)
Remote Channel Temperature Sensor Thermocouple Types
J, K, T, E, R, S, B, N
Remote Channel Temperature
Range, Resolution and Accuracy *See Table Below for Details
Pressure Range (Nominal) 0 to 2 inH2O (differential) 0 to 5 inH2O (differential)
Pressure Range (Max) -2 to +4 inH2O (differential) -2 to +8 inH2O (differential)
Pressure Resolution 0.002 inH2O 0.005 inH2O
Pressure Accuracy 0.5%FSR, 0.25% @ 25 °C Typical
Cold Jct. Compensation Automatic
Channels 2 Internal & 1 Remote
Memory 21,844/channel
Reading Rate 1 reading every 2 seconds up to 1 reading every 12 hours
LED Indicator Red
Required Interface Package IFC110 or IFC200
Baud Rate 57,600
Typical Battery Life 2 years
Operating Environment -20 °C to +80 °C (-4 °F to +176 °F),
0 to 95%RH (non-condensing)
Dimensions 2.7 in x 1.6 in x 0.8 in (68 mm x 41 mm x 20 mm)
Material ABS plastic
Weight 8.8 oz (250 g)
Approvals CE
* Remote Channel
Thermocouple Range (°C) Resolution Accuracy
J -210 to +760 0.1 °C +0.5 °C
K -260 to +1370 0.1 °C +0.5 °C
T -260 to +400 0.1 °C +0.5 °C
E -260 to +980 0.1 °C +0.5 °C
R -50 to +1760 0.5 °C +2.0 °C
S -50 to +1760 0.5 °C +2.0 °C
B +60 to +1820 0.5 °C +2.0 °C
N -260 to +1300 0.1 °C +0.5 °C
Product Information Card
Product Notes
Pressure Sensor
The PRTC110 measures differential pressure in the range of 0 to 2inH2O or 0 to 5inH20,
depending upon the range purchased. The device is also equipped with one thermocouple
input. Two 0.080” diameter pressure ports are located on the side of the device. The
pressure ports will accept 1/16”ID flexible rubber tubing with up to 5/32”OD. The tubing
can be connected to two different pressure locations in which the device will measure the
difference between the two pressure’s.
LEDs
Once started, the LED will flash at the selected reading rate to indicate that the device is
running.
Thermocouple Type
-To change the thermocouple type in the MadgeTech software:
- In the Connected Devices panel, click the device desired.
- On the Device Tab, in the Information Group, click Properties. Or, right-click the device
and select Properties in the context menu.
- On the General Tab, change the Thermocouple type in the drop down menu.
- Apply these changes, there will be a prompt to reset the device, select yes.
Please note that the same thermocouple type must be used on all of the channels.
Installation Guide
Installing the Interface cable
- IFC200
Insert the device into a USB port. The drivers will install automatically.
- IFC110
Plug the serial cable into the port and verify it is secure.
Installing the software
Insert the Software USB Stick in an open USB port. If the autorun does not appear, locate
the drive on the computer and double click on Autorun.exe. Follow the instructions
provided in the Wizard.
Device Operation
Connecting and Starting the data logger
- Once the software is installed and running, plug the interface cable into the data logger.
- Connect the USB end of the interface cable into an open USB port on the computer.
- The device will appear in the Connected Devices list, highlight the desired data logger.
- For most applications, select “Custom Start” from the menu bar and choose the desired
start method, reading rate and other parameters appropriate for the data logging
application and click “Start”. (“Quick Start” applies the most recent custom start options,
“Batch Start” is used for managing multiple loggers at once, “Real Time Start” stores the
dataset as it records while connected to the logger.)
PRTC110 Product Information Card
- The status of the device will change to “Running”, “Waiting to Start” or “Waiting to
Manual Start”, depending upon your start method.
- Disconnect the data logger from the interface cable and place it in the environment to
measure.
Note: The device will stop recording data when the end of memory is reached or the device is stopped. At this point the device
cannot be restarted until it has been re-armed by the computer.
Downloading data from a data logger
- Connect the logger to the interface cable.
- Highlight the data logger in the Connected Devices list. Click “Stop” on the menu bar.
- Once the data logger is stopped, with the logger highlighted, click “Download”. You will
be prompted to name your report.
- Downloading will offload and save all the recorded data to the PC.
Device Maintenance
Battery Replacement
Materials:
Small Phillips Head Screwdriver
Replacement Battery (LTC-7PN)
- Puncture the center of the back label with the screw driver and unscrew the enclosure.
- Remove the battery by pulling it perpendicular to the circuit board.
- Insert the new battery into the terminals and verify it is secure.
- Screw the enclosure back together securely.
Note: Be sure not to over tighten the screws or strip the threads.
Recalibration
The PRTC110 standard calibration is two pressure points at 14.7 PSI and 30 PSI and one
point at 0mVs for the thermocouple channel.

Other MadgeTech Data Logger manuals

MadgeTech RFC1000 User manual

MadgeTech

MadgeTech RFC1000 User manual

MadgeTech PRTemp1000 Specification sheet

MadgeTech

MadgeTech PRTemp1000 Specification sheet

MadgeTech Shock101-5 User manual

MadgeTech

MadgeTech Shock101-5 User manual

MadgeTech Volt101A User manual

MadgeTech

MadgeTech Volt101A User manual

MadgeTech MicroTemp100 Specification sheet

MadgeTech

MadgeTech MicroTemp100 Specification sheet

MadgeTech Logicbus X Series Specification sheet

MadgeTech

MadgeTech Logicbus X Series Specification sheet

MadgeTech PRHTemp2000 User manual

MadgeTech

MadgeTech PRHTemp2000 User manual

MadgeTech HiTemp1400 User manual

MadgeTech

MadgeTech HiTemp1400 User manual

MadgeTech Bridge120 User manual

MadgeTech

MadgeTech Bridge120 User manual

MadgeTech Therm-A-lert Specification sheet

MadgeTech

MadgeTech Therm-A-lert Specification sheet

MadgeTech PRTemp1000IS Specification sheet

MadgeTech

MadgeTech PRTemp1000IS Specification sheet

MadgeTech QuadTemp2000 User manual

MadgeTech

MadgeTech QuadTemp2000 User manual

MadgeTech CTL2000 User manual

MadgeTech

MadgeTech CTL2000 User manual

MadgeTech RTDTempX Series Specification sheet

MadgeTech

MadgeTech RTDTempX Series Specification sheet

MadgeTech HiTemp140-FP User manual

MadgeTech

MadgeTech HiTemp140-FP User manual

MadgeTech SciTemp140-PT Specification sheet

MadgeTech

MadgeTech SciTemp140-PT Specification sheet

MadgeTech QuadState User manual

MadgeTech

MadgeTech QuadState User manual

MadgeTech HiTemp140-FR-TSK Specification sheet

MadgeTech

MadgeTech HiTemp140-FR-TSK Specification sheet

MadgeTech Titan S8 Specification sheet

MadgeTech

MadgeTech Titan S8 Specification sheet

MadgeTech Shock101-50 Specification sheet

MadgeTech

MadgeTech Shock101-50 Specification sheet

MadgeTech PRTemp140 Specification sheet

MadgeTech

MadgeTech PRTemp140 Specification sheet

MadgeTech Bridge101A User manual

MadgeTech

MadgeTech Bridge101A User manual

MadgeTech AVS140-1 Specification sheet

MadgeTech

MadgeTech AVS140-1 Specification sheet

MadgeTech HiTemp140X2 Series Specification sheet

MadgeTech

MadgeTech HiTemp140X2 Series Specification sheet

Popular Data Logger manuals by other brands

Besantek BST-DL10 Instructional manual

Besantek

Besantek BST-DL10 Instructional manual

TESTO 0572 2200 Series instruction manual

TESTO

TESTO 0572 2200 Series instruction manual

EasyLog EL-USB-1 Operation guide

EasyLog

EasyLog EL-USB-1 Operation guide

Hobo UA-003-64 manual

Hobo

Hobo UA-003-64 manual

Pego PLUSR 200 EXPERT Use and maintenance manual

Pego

Pego PLUSR 200 EXPERT Use and maintenance manual

MASERMIC LOGS50 installation manual

MASERMIC

MASERMIC LOGS50 installation manual

Lascar EL-PDF-1 Series quick start guide

Lascar

Lascar EL-PDF-1 Series quick start guide

Texas Instruments CBL Guide book

Texas Instruments

Texas Instruments CBL Guide book

Convergence Instruments NSRTW mk3 user manual

Convergence Instruments

Convergence Instruments NSRTW mk3 user manual

YOKOGAWA MW100 user manual

YOKOGAWA

YOKOGAWA MW100 user manual

Geolux SmartObserver user manual

Geolux

Geolux SmartObserver user manual

TESTO 160 TH Short instructions

TESTO

TESTO 160 TH Short instructions

Keydemon USB 2GB user guide

Keydemon

Keydemon USB 2GB user guide

Kvaser Memorator Light user guide

Kvaser

Kvaser Memorator Light user guide

Decagon Devices EM50G manual

Decagon Devices

Decagon Devices EM50G manual

EasyLog EL-SIE quick start guide

EasyLog

EasyLog EL-SIE quick start guide

Fluke 2680A user manual

Fluke

Fluke 2680A user manual

In-situ Rugged TROLL 200 quick start guide

In-situ

In-situ Rugged TROLL 200 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.