PRTC110
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE,
FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE. BATTERY MAY
LEAK OR EXPLODE IF HEATED ABOVE 80 °C (176 °F).
Specifications subject to change.
See MadgeTech’s terms and conditions
PRTC110
Differential Pressure and Thermocouple
Temperature Data Logger
Description PRTC110
Internal Channel Temperature Sensor Semiconductor
Internal Channel Temperature Range -20 °C to +80 °C (-4 °F to +176 °F)
Internal Channel Temperature Resolution 0.1 °C (0.18 °F)
Internal Channel Temperature Accuracy +0.5 °C (+0.9 °F)
Remote Channel Temperature Sensor Thermocouple Types
J, K, T, E, R, S, B, N
Remote Channel Temperature
Range, Resolution and Accuracy *See Table Below for Details
Pressure Range (Nominal) 0 to 2 inH2O (differential) 0 to 5 inH2O (differential)
Pressure Range (Max) -2 to +4 inH2O (differential) -2 to +8 inH2O (differential)
Pressure Resolution 0.002 inH2O 0.005 inH2O
Pressure Accuracy 0.5%FSR, 0.25% @ 25 °C Typical
Cold Jct. Compensation Automatic
Channels 2 Internal & 1 Remote
Memory 21,844/channel
Reading Rate 1 reading every 2 seconds up to 1 reading every 12 hours
LED Indicator Red
Required Interface Package IFC110 or IFC200
Baud Rate 57,600
Typical Battery Life 2 years
Operating Environment -20 °C to +80 °C (-4 °F to +176 °F),
0 to 95%RH (non-condensing)
Dimensions 2.7 in x 1.6 in x 0.8 in (68 mm x 41 mm x 20 mm)
Material ABS plastic
Weight 8.8 oz (250 g)
Approvals CE
* Remote Channel
Thermocouple Range (°C) Resolution Accuracy
J -210 to +760 0.1 °C +0.5 °C
K -260 to +1370 0.1 °C +0.5 °C
T -260 to +400 0.1 °C +0.5 °C
E -260 to +980 0.1 °C +0.5 °C
R -50 to +1760 0.5 °C +2.0 °C
S -50 to +1760 0.5 °C +2.0 °C
B +60 to +1820 0.5 °C +2.0 °C
N -260 to +1300 0.1 °C +0.5 °C
Product Information Card
Product Notes
Pressure Sensor
The PRTC110 measures differential pressure in the range of 0 to 2inH2O or 0 to 5inH20,
depending upon the range purchased. The device is also equipped with one thermocouple
input. Two 0.080” diameter pressure ports are located on the side of the device. The
pressure ports will accept 1/16”ID flexible rubber tubing with up to 5/32”OD. The tubing
can be connected to two different pressure locations in which the device will measure the
difference between the two pressure’s.
LEDs
Once started, the LED will flash at the selected reading rate to indicate that the device is
running.
Thermocouple Type
-To change the thermocouple type in the MadgeTech software:
- In the Connected Devices panel, click the device desired.
- On the Device Tab, in the Information Group, click Properties. Or, right-click the device
and select Properties in the context menu.
- On the General Tab, change the Thermocouple type in the drop down menu.
- Apply these changes, there will be a prompt to reset the device, select yes.
Please note that the same thermocouple type must be used on all of the channels.
Installation Guide
Installing the Interface cable
- IFC200
Insert the device into a USB port. The drivers will install automatically.
- IFC110
Plug the serial cable into the port and verify it is secure.
Installing the software
Insert the Software USB Stick in an open USB port. If the autorun does not appear, locate
the drive on the computer and double click on Autorun.exe. Follow the instructions
provided in the Wizard.
Device Operation
Connecting and Starting the data logger
- Once the software is installed and running, plug the interface cable into the data logger.
- Connect the USB end of the interface cable into an open USB port on the computer.
- The device will appear in the Connected Devices list, highlight the desired data logger.
- For most applications, select “Custom Start” from the menu bar and choose the desired
start method, reading rate and other parameters appropriate for the data logging
application and click “Start”. (“Quick Start” applies the most recent custom start options,
“Batch Start” is used for managing multiple loggers at once, “Real Time Start” stores the
dataset as it records while connected to the logger.)
PRTC110 Product Information Card
- The status of the device will change to “Running”, “Waiting to Start” or “Waiting to
Manual Start”, depending upon your start method.
- Disconnect the data logger from the interface cable and place it in the environment to
measure.
Note: The device will stop recording data when the end of memory is reached or the device is stopped. At this point the device
cannot be restarted until it has been re-armed by the computer.
Downloading data from a data logger
- Connect the logger to the interface cable.
- Highlight the data logger in the Connected Devices list. Click “Stop” on the menu bar.
- Once the data logger is stopped, with the logger highlighted, click “Download”. You will
be prompted to name your report.
- Downloading will offload and save all the recorded data to the PC.
Device Maintenance
Battery Replacement
Materials:
Small Phillips Head Screwdriver
Replacement Battery (LTC-7PN)
- Puncture the center of the back label with the screw driver and unscrew the enclosure.
- Remove the battery by pulling it perpendicular to the circuit board.
- Insert the new battery into the terminals and verify it is secure.
- Screw the enclosure back together securely.
Note: Be sure not to over tighten the screws or strip the threads.
Recalibration
The PRTC110 standard calibration is two pressure points at 14.7 PSI and 30 PSI and one
point at 0mVs for the thermocouple channel.

Other MadgeTech Data Logger manuals

MadgeTech HiTemp140-FR Specification sheet

MadgeTech

MadgeTech HiTemp140-FR Specification sheet

MadgeTech octtemp 2000 User manual

MadgeTech

MadgeTech octtemp 2000 User manual

MadgeTech Bridge101A-30 User manual

MadgeTech

MadgeTech Bridge101A-30 User manual

MadgeTech TSR101 Series User manual

MadgeTech

MadgeTech TSR101 Series User manual

MadgeTech Temp1000IS Specification sheet

MadgeTech

MadgeTech Temp1000IS Specification sheet

MadgeTech UltraShock Specification sheet

MadgeTech

MadgeTech UltraShock Specification sheet

MadgeTech RFOT Specification sheet

MadgeTech

MadgeTech RFOT Specification sheet

MadgeTech HiTemp140-5.25-TD Specification sheet

MadgeTech

MadgeTech HiTemp140-5.25-TD Specification sheet

MadgeTech pHTemp2000 User manual

MadgeTech

MadgeTech pHTemp2000 User manual

MadgeTech Cryo-Temp User manual

MadgeTech

MadgeTech Cryo-Temp User manual

MadgeTech RHTemp101 User manual

MadgeTech

MadgeTech RHTemp101 User manual

MadgeTech HiTemp140 Series Specification sheet

MadgeTech

MadgeTech HiTemp140 Series Specification sheet

MadgeTech Cryo-Temp Specification sheet

MadgeTech

MadgeTech Cryo-Temp Specification sheet

MadgeTech DHS User manual

MadgeTech

MadgeTech DHS User manual

MadgeTech Temp101 User manual

MadgeTech

MadgeTech Temp101 User manual

MadgeTech TEMP1000EX User manual

MadgeTech

MadgeTech TEMP1000EX User manual

MadgeTech TSR101-EB User manual

MadgeTech

MadgeTech TSR101-EB User manual

MadgeTech QuadTemp2000 User manual

MadgeTech

MadgeTech QuadTemp2000 User manual

MadgeTech RHTEMP1000EX Specification sheet

MadgeTech

MadgeTech RHTEMP1000EX Specification sheet

MadgeTech HITEMP140-1 Specification sheet

MadgeTech

MadgeTech HITEMP140-1 Specification sheet

MadgeTech OctProcess Series User manual

MadgeTech

MadgeTech OctProcess Series User manual

MadgeTech MicroTemp100 Specification sheet

MadgeTech

MadgeTech MicroTemp100 Specification sheet

MadgeTech Temp1000 User manual

MadgeTech

MadgeTech Temp1000 User manual

MadgeTech RFCurrent2000A Specification sheet

MadgeTech

MadgeTech RFCurrent2000A Specification sheet

Popular Data Logger manuals by other brands

SIRETTA SNYPER-LTE graphyte Quick user guide

SIRETTA

SIRETTA SNYPER-LTE graphyte Quick user guide

Extech Instruments 380340 user guide

Extech Instruments

Extech Instruments 380340 user guide

NexSens Technology iSIC-OEM Operation manual

NexSens Technology

NexSens Technology iSIC-OEM Operation manual

Schlumberger Diver-NETZ manual

Schlumberger

Schlumberger Diver-NETZ manual

exemys GRD-MQ Series user manual

exemys

exemys GRD-MQ Series user manual

ELPRO ECOLOG-NET LP4 manual

ELPRO

ELPRO ECOLOG-NET LP4 manual

Measurement Computing USB-1808X-OEM user guide

Measurement Computing

Measurement Computing USB-1808X-OEM user guide

sebaKMT Sebalog N3 user manual

sebaKMT

sebaKMT Sebalog N3 user manual

sauermann 220 Series user manual

sauermann

sauermann 220 Series user manual

TiTLEY Scientific AnaBat Roost Logger quick start guide

TiTLEY Scientific

TiTLEY Scientific AnaBat Roost Logger quick start guide

Banner SureCross Performance DX80N9X2S-P3 FlexPower manual

Banner

Banner SureCross Performance DX80N9X2S-P3 FlexPower manual

Solvera Lynx COMBOX.L user manual

Solvera Lynx

Solvera Lynx COMBOX.L user manual

QUNDIS Q log 5.5 quick start

QUNDIS

QUNDIS Q log 5.5 quick start

Neuralynx LabLynx user manual

Neuralynx

Neuralynx LabLynx user manual

Eagle Tree Systems EGT-01 instruction manual

Eagle Tree Systems

Eagle Tree Systems EGT-01 instruction manual

Parsyl Trek Tab TREKC1 user guide

Parsyl

Parsyl Trek Tab TREKC1 user guide

Skye DATAHOG 2 instructions

Skye

Skye DATAHOG 2 instructions

Comet Commeter D3633 instruction manual

Comet

Comet Commeter D3633 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.