manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MadgeTech
  6. •
  7. Data Logger
  8. •
  9. MadgeTech QuadState User manual

MadgeTech QuadState User manual

This manual suits for next models

1

Other MadgeTech Data Logger manuals

MadgeTech Event101A Specification sheet

MadgeTech

MadgeTech Event101A Specification sheet

MadgeTech Temp101 User manual

MadgeTech

MadgeTech Temp101 User manual

MadgeTech HiTemp150FP-TSK User manual

MadgeTech

MadgeTech HiTemp150FP-TSK User manual

MadgeTech HiTemp140-M12 Specification sheet

MadgeTech

MadgeTech HiTemp140-M12 Specification sheet

MadgeTech RTDTemp101A User manual

MadgeTech

MadgeTech RTDTemp101A User manual

MadgeTech RTDTempX Series Specification sheet

MadgeTech

MadgeTech RTDTempX Series Specification sheet

MadgeTech TCTemp1000 User manual

MadgeTech

MadgeTech TCTemp1000 User manual

MadgeTech PR1000 Specification sheet

MadgeTech

MadgeTech PR1000 Specification sheet

MadgeTech VFC2000 User manual

MadgeTech

MadgeTech VFC2000 User manual

MadgeTech OctProcessV2 Specification sheet

MadgeTech

MadgeTech OctProcessV2 Specification sheet

MadgeTech ThermoVault Specification sheet

MadgeTech

MadgeTech ThermoVault Specification sheet

MadgeTech TC101A User manual

MadgeTech

MadgeTech TC101A User manual

MadgeTech RFOT Specification sheet

MadgeTech

MadgeTech RFOT Specification sheet

MadgeTech UltraShock Specification sheet

MadgeTech

MadgeTech UltraShock Specification sheet

MadgeTech Shock101 Specification sheet

MadgeTech

MadgeTech Shock101 Specification sheet

MadgeTech CTL2000 User manual

MadgeTech

MadgeTech CTL2000 User manual

MadgeTech Temp1000S User manual

MadgeTech

MadgeTech Temp1000S User manual

MadgeTech HiTemp140-5.25 Specification sheet

MadgeTech

MadgeTech HiTemp140-5.25 Specification sheet

MadgeTech RFPulse2000A User manual

MadgeTech

MadgeTech RFPulse2000A User manual

MadgeTech Logicbus X Series Specification sheet

MadgeTech

MadgeTech Logicbus X Series Specification sheet

MadgeTech Shock101-EB-5 User manual

MadgeTech

MadgeTech Shock101-EB-5 User manual

MadgeTech QuadTCTempV2 Specification sheet

MadgeTech

MadgeTech QuadTCTempV2 Specification sheet

MadgeTech HiTemp150-TSK User manual

MadgeTech

MadgeTech HiTemp150-TSK User manual

MadgeTech QuadRTD User manual

MadgeTech

MadgeTech QuadRTD User manual

Popular Data Logger manuals by other brands

UGCS SkyHub user manual

UGCS

UGCS SkyHub user manual

Avisaro 4.0 Series user manual

Avisaro

Avisaro 4.0 Series user manual

DDB C3 manual

DDB

DDB C3 manual

TESTO 176 instruction manual

TESTO

TESTO 176 instruction manual

HBM SOMAT XR CX22B-R operating manual

HBM

HBM SOMAT XR CX22B-R operating manual

Agtrix 380i manual

Agtrix

Agtrix 380i manual

Beijing ART Tech PCI2320 user manual

Beijing ART Tech

Beijing ART Tech PCI2320 user manual

Athena GET SL1 user manual

Athena

Athena GET SL1 user manual

Motec Systems C185 user manual

Motec Systems

Motec Systems C185 user manual

Beijing ART Tech USB2832 user manual

Beijing ART Tech

Beijing ART Tech USB2832 user manual

HT Italia XL421 user manual

HT Italia

HT Italia XL421 user manual

Racelogic VBOX LapTimer quick start guide

Racelogic

Racelogic VBOX LapTimer quick start guide

Edu-Logger 900-240 Guide

Edu-Logger

Edu-Logger 900-240 Guide

Elma DT173 manual

Elma

Elma DT173 manual

Comet U0121M user guide

Comet

Comet U0121M user guide

pico Technology PT-104 user guide

pico Technology

pico Technology PT-104 user guide

Sensus DIAVASO user manual

Sensus

Sensus DIAVASO user manual

Soil Instruments GTecLink user manual

Soil Instruments

Soil Instruments GTecLink user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE,
FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE. BATTERY MAY
LEAK OR EXPLODE IF HEATED ABOVE 60°C (140°F).
QuadState and OctState
QuadState
4-Channel State Data Logger
OctState
8-Channel State Data Logger
Part Number QuadState OctState
Input Range 0 to 12VDC continuous; (0 to 30VDC peak)
Input Low <0.4V
Input High >2.7V
Internal Weak Pull-Up <500µA
Recommended Duty Cycle for
Inputs Greater Than 12VDC
(over 1 minute interval)
18V: <50%
24V: <25%
30V: <10%
Resolution 1 second
Channels 4 8
Memory 52,428 states
Sample Rate 1 second to 12 hours
LED Indicator None
Required Interface Package IFC110 or IFC200
Baud Rate 2,400
Typical Battery Life 1 year
Operating Environment -20 to +60°C, 0 to 95%RH (non–condensing)
Material Anodized aluminum
Dimensions 3.5” x 4.4” x 1.0”
(89mm x 112mm x 26mm)
3.5” x 4.4” x 1.5”
(89mm x 112mm x 39mm)
Approvals -
Product Information Card
www.calcert.com [email protected]1.800.544.2843 0
5
10
15
20
25
30
Wiring the Data Logger
Wiring Options
The QuadState and OctState both have a two-position removable screw terminal
connection. They accept 2-wire configurations.
Warning: Note the polarity instructions. Do not attach wires to the wrong terminals.
Product Notes
Engineering Units
Engineering units are used to convert one measurement reading to another. The
MadgeTech software allows for software level Engineering Units (conversion applied to
data after download). Certain devices have device level Engineering Units, which upon
download automatically appear in the chosen unit of measure.
Please refer to the app note “Engineering Units”, found on the MadgeTech website, for
information on how to manage Engineering Units. Also view the Engineering Units Video
for step-by-step setup instructions.
Installation Guide
Installing the Interface cable
- IFC200
Insert the device into a USB port. The drivers will install automatically.
- IFC110
Plug the serial cable into the port and verify it is secure.
Installing the software
Insert the Software CD in the CD-ROM Drive. If the autorun does not appear, locate the
drive on the computer and double click on Autorun.exe. Follow the instructions provided
in the Wizard.
Connecting the data logger
- Once the software is installed and running, plug the interface cable into the data logger.
- Click the Communication Menu, then Auto Configure Port.
- After a moment, a box will appear stating a device has been found.
- Click OK. The Device Status box will appear. Click OK.
- At this point, communications have been configured for the logger. These settings can
be found under the Communication Menu.
Note: For additional installation instructions refer to the “Data Logger & Software Operating Manual”.
Product Information Card
QuadState and OctState
Device Operation
Starting the data logger
- Click Device Menu then Start Device.
- Choose the desired start method.
- Choose the start parameters by selecting a Reading Rate suitable for the application.
- Enter in any other desired parameters and click Start.
- A box will appear stating the data logger has been started. Click OK.
- Disconnect the data logger from the interface cable and place it in the environment to
measure.
Note: The device will stop recording data when the end of memory is reached or the device is stopped. At this point the device
cannot be restarted until it has been re-armed by the computer.
Downloading data from a data logger
- Connect the data logger to the interface cable.
- Click the Device Menu then Read Device Data. This will offload all recorded data onto
the PC.
Device Maintenance
Battery Replacement
Materials:
3/32” HEX Driver (Allen Key)
Replacement Battery (U9VL-J)
- Remove the cover from the device by unscrewing the four screws.
- Remove the battery from its compartment and unsnap it from the connector.
- Snap the new battery into the terminals and verify it is secure.
- Replace the cover taking care not to pinch the wires. Screw the enclosure back together
securely.
Note: Be sure not to over tighten the screws or strip the threads.
Recalibration
The QuadState or OctState cannot be calibrated. A certificate of conformance can be
provided.
Connector for interface cable
+ Input
- Input
www.calcert.com [email protected]1.800.544.2843 0
5
10
15
20
25
30