Configurable
Fascia and
Duct Connection
Solution
CONTOUR
IMPORTANT
This fan unit must be installed by a registered electrician and its installation and connection to the power supply must comply with all current Australian
and New Zealand electrical and building regulations including AS/NZS3000:2017, or latest edition thereof.
The power supply cable must be suitably rated by a registered electrician to satisfy the total load on that circuit.
WARNING
1. This unit may only be used as recommended by the manufacturer in this manual. Any other use not recommended by the manufacturer may
cause fire, electric shock, or injury to persons. Contact the manufacturer, or local agent, if required.
2. Isolate the mains supply before making any electrical connections. This system should be installed by a registered electrician.
3. Ensure the unit is properly earthed.
4. The unit must be able to be isolated from the power by means of a disconnect switch meeting current electrical regulations.
5. The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience
and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
6. Children should be supervised to ensure that they do not play with the appliance.
IMPORTANT CONSIDERATIONS BEFORE INSTALLING
Planning can make a big difference to the installation time and your satisfaction with the operation of the unit.
1. This fan is to be installed so that the blades are more than 2.2m above the floor.
2. The unit must be mounted outside the shower cubicle.
3. For the exhaust fan to work efficiently, replacement air, of a volume equivalent to the air being extracted, must be able to enter the room. This air
is usually drawn from under the door, or through a slightly open window. If the room is airtight, however, the fan will function poorly.
4. This unit is designed for installation into a flat ceiling only.
5. Before commencing any cutting, check in the ceiling space that there are no obstructions such as ceiling joists and that there is sufficient height
clearance for the housing. Check that the electrical wiring can be routed from the wall switch to the mounting location.
6. If any of the fan supply cords are damaged, they musr be replaced by the manufactuter, its service agent, or similarly qualified persons, in order
to avoid possible damage to the fan motor or controller.
7. Precautions must be taken to avoid the back-flow of gases into the room from the open flue of gas or other open-fire appliances when mounted
in outside walls or soffits.
8. Any changes, or modifications, made, or attempted, to this product, without the prior written approval of the manufacturer, will void any, and all,
stated warranties.
FAN INSTALLATION AND ELECTRICAL CONNECTION MUST
BE CARRIED OUT BY A REGISTERED ELECTRICIAN
BEFORE INSTALLING THE FAN, MAKE SURE YOU HAVE TURNED OFF THE MAIN ELECTRICITY SUPPLY.
DO NOT TURN IT BACK ON UNTIL THE FAN IS FULLY INSTALLED AND READY TO USE.
ALL ELECTRICAL WORK MUST BE CARRIED OUT BY A REGISTERED ELECTRICIAN IN ACCORDANCE
WITH THE LATEST WIRING RULES AS/NZS3000.