Installation Manual
Type:NDR DIN rail power supply(Series:NDR-75, 120, 240, 480)
NDR-75-12 INPUT: 100-240VAC 1.6A 50/60Hz OUTPUT: 12V 6.3A
NDR-75-24 INPUT: 100-240VAC 1.6A 50/60Hz OUTPUT: 24V 3.2A
NDR-75-48 INPUT: 100-240VAC 1.6A 50/60Hz OUTPUT: 24V 1.6A
NDR-120-12 INPUT: 100-240VAC 2.6A 50/60Hz OUTPUT: 12V 10A
NDR-120-24 INPUT: 100-240VAC 2.6A 50/60Hz OUTPUT: 24V 5A
NDR-120-48 INPUT: 100-240VAC 2.6A 50/60Hz OUTPUT: 48V 2.5A
NDR-240-24 INPUT: 100-240VAC 2.8A 50/60Hz OUTPUT: 24V 10A
NDR-240-48 INPUT: 100-240VAC 2.8A 50/60Hz OUTPUT: 48V 5A
NDR-480-24 INPUT: 100-240VAC 5.3A 50/60Hz OUTPUT: 24V 20A
NDR-480-48 INPUT: 100-240VAC 5.3A 50/60Hz OUTPUT: 48V 10A
Introduction
NDR is a DIN rail power supply series with an economical price and slim design. Like other Mean Well’s DIN series,
they can be mounted on a TS35 Standard DIN rail.
Installation
(1)Always allow good ventilation clearances, 5mm left and right, 40mm above and 20mm below, around the unit
in use to prevent it from overheating. Also a 10-15 cm clearance must be kept when the adjacent device is a
heat source.
(2)The appropriate mounting orientation for the unit is vertical, the input terminals at the bottom and output on
the top. Mounting orientations other than that, such as upside down, horizontal, or table-top mounting, is not
allowed.
(3)Use copper wire only, and recommended wires are shown as below.
AWG 18 16 14 12
Rated Current of
Equipment (Amp) 7A 10A 15A 20A
Cross-section of
Lead(mm2) 0.8 1.3 2.1 3.3
Note: Current each wire carries should be de-rated to 80% of the current suggested
above when using 5 or more wires connected to the unit.
Make sure that all strands of each stranded wire enter the terminal connection and the screw terminals are
securely fixed to prevent poor contact. If the power supply possesses multi-output terminals, please make
sure each contact is connected to wires to prevent too much current stress on a single contact.
(4)Use wires that can withstand temperatures of at least 80°C, such as UL1007.
(5)Recommended wire strapping length is 5mm (0.197”).
(6)Recommended screwdriver is 3mm, slotted type.
Installation Manual
3
12
4
(7)The recommended torque setting for terminals is shown as below.
Model I/P O/P
NDR-75 6.9 kgf-cm (6 Lb-in) 6.9 kgf-cm (6 Lb-in)
NDR-120 7.5 kgf-cm (6.5 Lb-in) 7.5 kgf-cm (6.5 Lb-in)
NDR-240 7.5 kgf-cm (6.5 Lb-in) 7.5 kgf-cm (6.5 Lb-in)
NDR-480 10.35 kgf-cm (9 Lb-in) 10.35 kgf-cm (9 Lb-in)
(8)Suggested fuse and maximum number of the PSUs that can be connected to a circuit breaker at 230V are shown
as below.
Model Fuse
Circuit breaker
C16 D16
NDR-75 T3.15A/L250V 6 13
NDR-120 T4A/L250V 5 10
NDR-240 T5A/L250V 4 10
NDR-480 T8A/L250V 3 5
(9)Mounting Instruction:
Mount as shown in figure only, with input terminals down, or else sufficient cooling will not be possible.
Admissible DIN rail:TS35/7.5 or TS35/15
For rail fastening:
(a)Tilt the unit slightly rearwards.
(b)Fit the unit over top hat rail.
(c)Slide it downward until it hits the stop.
(d)Press against the bottom for locking.
(e)Shake the unit slightly to check the locking action.
(10)For other information about the products, please refer to www.meanwell.com for details.
Warning / Caution !!
(1)Risk of electrical shock and energy hazard. All failure should be examined by a qualified technician. Please do
not remove the case of the power supply by yourself!
(2)Risk of electric arcs and electric shock (danger to life). Connecting both the primary and the secondary sides
together is not allowed.
(3)Risk of burn hazard. Do not touch the unit in operation and shortly after disconnection!
(4)Risk of fire and short circuit. The openings should be protected from foreign objects or dripping liquids.
(5)Only install the unit in a pollution degree 2 environment (Note.1).
(6)Please do not install the unit in places with high moisture or near the water.
"Click"
Installation Manual
(7)The maximum operating temperature is 45°C for NDR/EDR-75-12; 50°C for NDR/EDR-75-24/48,
NDR/EDR-120-12/24/48, NDR-240-24/48, NDR-480-24/48, please do not install the unit in places with high
ambient temperature or near fire source.
(8)The FG ( ) must be connected to PE (Protective Earth).
(9)Output current and output wattage must not exceed the rated value on its specification.
(10)Disconnect system from supply voltage:
Before commencing any installation, maintenance or modification work: Disconnect your system from
supply voltage. Make sure that inadvertent connection in circuit will be impossible!
(11)For continued protection against risk of fire, replace only with same type and rating of fuse.
Pour ne pas compromettre la protection contre les risqué d’incendie, remplacer par un fusible de même
type et de memes caractéristiques nominales.
Note.1: Pollution Degree 2 applies where there is only non-conductive pollution that might temporarily become
conductive due to occasional condensation. Generally refer to dry, well-ventilated locations, such as
control cabinets.
Manufacturer:
MEAN WELL ENTERPRISES Co., LTD.
No.28, Wuquan 3rd Rd., Wugu Dist.,
New Taipei City 24891, Taiwan
Tel: +886-2-2299-6100
Web: www.meanwell.com
Branch Office:
China
MEAN WELL (GUANGZHOU)
ENTERPRISES Co., LTD.
2F, A Building, Yuean lndustry Park,
Huangcun,Dongpu Yown, Tianhe
District, Gungzhou, China
Post Code:510660
Tel: +86-20-2887-1200
Web: www.meanwell.com.cn
U.S.A.
MEAN WELL USA, INC.
44030 Fremont Blvd., Fremont,
CA 94538, U.S.A.
Tel: +1-510-683-8886
Web: www.meanwellusa.com
Europe
MEAN WELL EUROPE B.V.
Langs de Werf 8, 1185XT
Amstelveen, The Netherlands
Tel: +31-20-758-6000
Web: www.meanwell.eu
Declaration of China RoHS Conformity
In order to reduce the impacts on the environment and take the more responsibility for protecting the
earth, MEAN WELL is confirming and announcing the conformity to China RoHS, an
Administrative Measures for the Restriction of the Use of Hazardous Substances in Electrical and
Electronic Products.
Environment Friendly Use Period Label
Observing SJT 11364-2014, Marking for the Restricted Use of Hazardous
Substances in Electronic and Electrical Products
Observing SJ/Z 11388-2009, General Guidelines of Environment-friendly
Use Period of Electronic Information ProductsAppendix B, adopting
table look-up to verify the Environment Friendly Use Period
Names and Contents of Hazardous Substances Lists
Part Name
Hazardous Substances
Lead
(Pb)
Mercury
(Hg)
Cadmium
(Cd)
Hexavalent
chromium
(Cr6+)
Polybrominated
biphenyls
(PBB)
Polybrominated
diphenyl ethers
(PBDE)
PCB and its
components
X
O
X
O
O
O
Metal structure
parts
X
O
O
O
O
O
Plastic structure
parts
O
O
O
O
O
O
Accessories
O
O
O
O
O
O
Cables
X
O
O
O
O
O
O: The concentration of the hazardous substances within the homogeneous material of that product is less than
the concentration limits set by GB/T 26572-2011.
X: The concentration of the hazardous substances within the homogeneous material of that product is over the
concentration limits set by GB/T 26572-2011; however, it follows the standard advised by 2011/65/EU.
Declaration of China VOC Conformity
In order to reduce the impacts on the environment and take the more responsibility
for protecting the earth, MEAN WELL is confirming and announcing the conformity to
China’s Standardization Administration Releases VOC Standards
Standard No. Name of the Standard
GB 30981-2020 Limit of harmful substances of industrial protective coatings
GB 33372-2020 Limits for volatile organic compounds content in adhesive
GB 38507-2020 Limits for volatile organic compounds (VOCs) In printing ink
GB 38508-2020 Limits for volatile organic compounds content in cleaning agents
Declaration of Five PBT TSCA Conformity
In order to reduce the impacts on the environment and take the more responsibility
for protecting the earth, MEAN WELL hereby confirms that MEAN WELL product
series comply with Use and Risk Management for Five PBT Chemicals under TSCA
section 6(h)
CAS No.
Substance Name
1163-19-5
Decabromodiphenyl ether (DecaBDE)
68937-41-7
Phenol, isopropylated, phosphate (3:1)
PIP (3:1)
732-26-3
2,4,6-Tris (tert-butyl) phenol (2,4,6-TTBP)
133-49-3
Pentachlorothiophenol (PCTP)
87-68-3
Hexachlorobutadiene (HCBD)

This manual suits for next models

9

Other Meanwell Power Supply manuals

Meanwell RCP-1600 Series User manual

Meanwell

Meanwell RCP-1600 Series User manual

Meanwell DRH-120-24 User manual

Meanwell

Meanwell DRH-120-24 User manual

Meanwell IRC1 User manual

Meanwell

Meanwell IRC1 User manual

Meanwell DR-15-5 User manual

Meanwell

Meanwell DR-15-5 User manual

Meanwell PWR24048 User manual

Meanwell

Meanwell PWR24048 User manual

Meanwell CSP Series User manual

Meanwell

Meanwell CSP Series User manual

Meanwell RST-7K5-HV Series User manual

Meanwell

Meanwell RST-7K5-HV Series User manual

Meanwell HEP-1000 User manual

Meanwell

Meanwell HEP-1000 User manual

Meanwell DDR-15G-3.3 User manual

Meanwell

Meanwell DDR-15G-3.3 User manual

Meanwell DRA Series User manual

Meanwell

Meanwell DRA Series User manual

Meanwell DDR-120 Series User manual

Meanwell

Meanwell DDR-120 Series User manual

Meanwell LCM-25 User manual

Meanwell

Meanwell LCM-25 User manual

Meanwell HEP-2300 Series User manual

Meanwell

Meanwell HEP-2300 Series User manual

Meanwell SHP-10K Series User manual

Meanwell

Meanwell SHP-10K Series User manual

Meanwell LCM-25 User manual

Meanwell

Meanwell LCM-25 User manual

Meanwell LPHC-18 User manual

Meanwell

Meanwell LPHC-18 User manual

Meanwell TDR-240-24 User manual

Meanwell

Meanwell TDR-240-24 User manual

Meanwell TDR-960 Series User manual

Meanwell

Meanwell TDR-960 Series User manual

Meanwell AP User manual

Meanwell

Meanwell AP User manual

Meanwell VFD Series User manual

Meanwell

Meanwell VFD Series User manual

Meanwell HEP-1000 User manual

Meanwell

Meanwell HEP-1000 User manual

Meanwell HDR-15 Series User manual

Meanwell

Meanwell HDR-15 Series User manual

Meanwell TDR-480-24 User manual

Meanwell

Meanwell TDR-480-24 User manual

Meanwell RKP-CMU1 User manual

Meanwell

Meanwell RKP-CMU1 User manual

Popular Power Supply manuals by other brands

Tru-Test 15 J R user manual

Tru-Test

Tru-Test 15 J R user manual

Rigol DP800 Series manual

Rigol

Rigol DP800 Series manual

Keysight RP7900 Series Advanced Service Guide

Keysight

Keysight RP7900 Series Advanced Service Guide

Yamaha PW2000M operating manual

Yamaha

Yamaha PW2000M operating manual

TDK-Lambda DPX Series Product handbook

TDK-Lambda

TDK-Lambda DPX Series Product handbook

Altronix R615DC8CB220 quick start guide

Altronix

Altronix R615DC8CB220 quick start guide

Junsi ZXY-6005S user manual

Junsi

Junsi ZXY-6005S user manual

Pima PS-2 installation guide

Pima

Pima PS-2 installation guide

Pulsar PSBOC1552455 manual

Pulsar

Pulsar PSBOC1552455 manual

Altronix AL300XB2V installation guide

Altronix

Altronix AL300XB2V installation guide

Pulsar ADOC551230 manual

Pulsar

Pulsar ADOC551230 manual

Matrix MPS-H-1 Series user manual

Matrix

Matrix MPS-H-1 Series user manual

Pulsar PSDC161216T quick start guide

Pulsar

Pulsar PSDC161216T quick start guide

Pro-face PS-4000B Series user manual

Pro-face

Pro-face PS-4000B Series user manual

Phihong POE75U-1UP-N-R user manual

Phihong

Phihong POE75U-1UP-N-R user manual

Whelen Engineering Company WPPS6924 installation guide

Whelen Engineering Company

Whelen Engineering Company WPPS6924 installation guide

Ocean Optics JAZ-EXT-BP50WH instructions

Ocean Optics

Ocean Optics JAZ-EXT-BP50WH instructions

Altronix Rack Mount Series installation guide

Altronix

Altronix Rack Mount Series installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.