
No. 99MAH016B
Contents
FOREWORD .......................................................................................................................................................i
PRECAITIONS....................................................................................................................................................i
WARRANTY.......................................................................................................................................................ii
NOTES ON OVERSEAS TRANSFER...............................................................................................................ii
1NAME OF RACH PART......................................................................................................................... 1-1
1.1 Part Names of the Main Unit ........................................................................................................ 1-1
1.2 Details of the LCD Unit ................................................................................................................. 1-2
2INSTALLATION...................................................................................................................................... 2-1
2.1 Attaching the Clamp Filter............................................................................................................ 2-1
2.2 Mounting on a Stand or a Jig....................................................................................................... 2-1
2.2 Attaching the Lifting Lever........................................................................................................... 2-1
2.3 Attaching the Release................................................................................................................... 2-2
2.4 Mounting the Lug or Special Back .............................................................................................. 2-2
2.5 Replacing the Contact Point ........................................................................................................ 2-2
3OPERATING PROCEDURE .................................................................................................................. 3-1
3.1 Starting/Stopping This Instrument.............................................................................................. 3-1
3.1.1 Connecting to the power supply.......................................................................................... 3-1
3.1.2 Start / Stop.............................................................................................................................. 3-1
3.2 Parameter Setup Mode ................................................................................................................. 3-1
3.2.1 Switching the unit system between inch and mm during display of “unit” (only in inch spec) ....3-2
3.2.2 Switching the digital resolution during display of “res.” .................................................. 3-2
3.2.3 Switching the analog range (analog resolution) during display of “range”.................... 3-3
3.2.4 Switching the count direction during display of “dir” ....................................................... 3-3
3.2.5 Switching the I/O format between SPC(Digimatic) and RS-232 during display of “output” ......... 3-3
3.2.5.1 RS-232 setup.................................................................................................................... 3-3
3.2.6 Setting ID No. for RS-232 communication and remote control during display of “id” .. 3-4
3.2.7 Switching the length measuring system during display of “start” .................................. 3-4
3.2.8 Returning all parameters to factory defaults during display of “reset” .......................... 3-4
3.3 Measurement Mode....................................................................................................................... 3-5
3.3.1 Setting the length measuring system and reference point............................................... 3-5
3.3.1.1 INC system (Zero set) ...................................................................................................... 3-5
3.3.1.2 Preset system (setting the preset value).......................................................................... 3-5
3.3.2 Switching a measurement type in the measurement mode.............................................. 3-6
3.3.2.1 Tolerance judgment (setting/checking the upper and lower limit values)......................... 3-6
3.3.2.2 Run-out peak hold during display of “TIR” ....................................................................... 3-7
3.3.2.3 Maximum value peak hold during display of “Max” .......................................................... 3-7
3.3.2.4 Minimum value peak hold during display of “Min” ............................................................ 3-8
3.3.3 Data output / Data hold ......................................................................................................... 3-9