HEALTH CHECK Ear and Forehead Thermometer
Model No.: 70125 DDX
Instruction Manual
Please read this instruction manual completely before operating.
Package Contents
Quantity
1pc
2pc
1pc
Parts
HEALTH CHECK Thermometer
1.5V (AAA) batteries
User Manual
Thermometer Specification
Power Supply:
Body Measuring Range:
Ear and Forehead Measure Accuracy:
Object Measuring Range:
Object Measure Accuracy:
Dimensions:
Weight:
Forehead operating Condition:
Ear and Object operating Condition:
Atmosphere pressure:
Service life:
Service life of the battery:
DC 3V (2 x AAA)
89.6°F –109.3°F (32.0°C –42.9°C)
Within range of 95.0°F –107.6°F (35.0°C-
42.0°C):
Accuracy = ±0.4°F (±0.2°C)
Outside of stated range:
Accuracy = ±0.5°F (±0.3°C)
41.0°F –139.8°F (5.0°C - 59.9°C)
±2.0°F (1.0°C)
150.0(L)x40.5(W)x 50.0(H)mm(±2mm)
61.0g (without batteries)
59.0°F –104.0°F (15.0°C –40.0°C)
With a relative humidity of 20% –85%
50.0°F –104.0°F (10.0°C –40.0°C)
With a relative humidity of 20% –85%
700hPa –1060hPa
2 years
6 months based on the use frequency at
5 times/day
Product Specification
1. Forehead Temperature Symbol
2. Ear Temperature Symbol
3. Object Temperature Symbol
4. Low Battery Symbol
5. Temperature Display
6. Celsius/Fahrenheit Symbol
7. Health Check
8. Cleaning Symbol
9. Memory Symbol
10. Temperature Trending Indication
Note: When the device is powered on all icons are temporarily displayed on
screen, this is not an indicator of battery power. Battery indicator will display
constantly when battery level is low.
1. Infrared Sensor
2. LCD Display
3. Power & Scan Button
4. Probe Cap
5. MEM/SET Button
6. Temperature Mode Selection
7. Battery Cover
Installing/Replacing Battery
Remove the battery cover by sliding it toward the bottom of the thermometer.
Insert or replace 2 x 1.5 AAA batteries into the battery compartment, ensuring to
match the indicating polarity symbols (always use new batteries).
Replace the battery cover on to the thermometer ensuring it snaps closed.
Note: ‘LO’ display on screen is not an indicator of low power. ‘LO’ is displayed
when temperature reading is low, this will happen if the device measures the air
temperature when powering on the device.
Temperature Indicators
Temperature Trend Indication Arrows: This indicator helps to easily identify
whether the temperature measurement result is higher or lower than the previous
temperature taken. If the temperature rises, the indicators will light upwards in
sequence; if the temperature drops the indicator will light downwards in sequence,
as shown below.
Temperature LED Indication: There are two color LED temperature indicators in this
unit. When a temperature is taken the corresponding light will illuminate around
the ‘POWER/SCAN’ button.
Green LED: 34.0°C (93.2°F) - 37.9°C (100.3°F)
Red LED: 38.0°C (100.4°F) - 43.0°C (109.4°F)
Celsius and Fahrenheit Setting
When thermometer is turned on press and hold the ‘MEM/SET’ button until you
hear a beep, to switch between Celsius and Fahrenheit.
Measurement Preparation For Best Results
For more accurate measurements always store the device in same environment it is
being used, for at least 30 minutes prior. An unexpected fluctuation of ambient
temperature is likely to lower measuring accuracy.
External factors may influence ear and forehead temperatures, particularly when
the individual has been:
•Lying on the ear to be measured or has it covered.
•Exposed to very hot or cold temperatures.
•Swimming or bathing causing the ear canal to be wet.
•Recently exercising, bathing or other physical exertion as this increase’s
temperature.
Do not talk or move body during measurement.
Make sure to dry forehead or keep ear canal clean. Unclean ear canal or excessive
hair may cause inaccurate reading.
The infrared sensor must be kept clean, dry and undamaged to ensure accurate
results. Please wait 5-15 minutes before taking measurement again.
Replace battery when low battery indicator is “ON”.
Use of this device is not intended as a substitution for consultation with your
physician. Measurement results are for reference only. Contact your physician if you
have or suspect and health concerns.
For individuals using hearing aids or ear plugs remove any such device and wait 30
minutes before taking an ear temperature.
Thermometer Operating Guide
Ear temperature measurement:
•Press the ‘SCAN/POWER’ button to turn the thermometer ‘On’.
•To measure temperature via ear, remove the forehead probe cover from the
unit.
•Press the ‘MODE’ button to switch to ear temperature mode, “ ” symbol will
be displayed on screen.
•Insert the ear probe tip slightly into the ear opening, then press & release the
‘SCAN’ button to measure the body temperature.
•Once you hear a short beep the body temperature will be displayed. Please
allow 6 seconds before the next reading. The “ ” icon will stop flashing in the
display.
Forehead temperature measurement:
•To measure temperature via the forehead, ensure forehead probe cover is
attached.
•Press the ‘MODE’ button to switch to forehead temperature mode “ ”
symbol will be displayed on screen.
•Gently touch the entire tip of the probe to the center of the forehead,
midway between the eyebrows and the hairline. Ensure no hair is obstructing
the unit, then press the ‘SCAN’ button, you will hear a short beep and the
temperature will be displayed.
Note: Results shown from 89.6°F to 109.4°F(32.0°C to 43°C). ‘HI’ is displayed for
all results above 109.4°F (43°C), and ‘LO’ displayed for result below 89.6°F
(32.0°C).
Object temperature measurement:
•Remove the forehead cap.
•Press the ‘MODE’ button to switch to ‘object’ mode. “ ” will show up on the
display.
•Hold the thermometer approximately 1cm away from the object surface,
press and release the ‘SCAN’ button aiming the measurement sensor at the
object.
•Once you hear the short beep the object temperature will be displayed.
Note: If display shows HI/LOW please make sure thermometer is in ‘object’
mode.
Care and Maintenance
Lens / Measurement Sensor: Gently clean with an alcohol swab. Do not use
water to wash the thermometer lens directly.
Thermometer: Clean with a soft, dry cloth. Do not use water to rinse the device.
Note: The thermometer is programmed to remind the user to clean the device,
‘ ’ will flash on screen. Press any button to exit this notification, and please
clean the unit.
Health Check
•Press buttons ‘MEM/SET’ and ‘MODE’ together for 2 seconds to enter the
countdown. Use the ‘MODE’ button to toggle between 15 minutes, 30
minutes or 45 minutes or OFF.
•Press the ‘MEM/SET’ button when the desired time is on screen to start
counting down. When the countdown is active and running in the
background the “ ” sign will flash on screen.
•When the countdown begins, the user can press ‘MEM/SET’ and ‘MODE’
button together for 2 seconds to display the remaining time, then press
‘SCAN’ button to return to waiting mode or press ‘MEM/SET’ button to cancel
the countdown.
•When the countdown is zero. Health check “ ” symbol will display on LCD and
the unit will ‘BEEP’ to remind the user. To stop the notification’s and return to
the home menu press any button.
Memory Function
•This unit can recall up to 9 prior measurements stored in memory.
•Turn on thermometer, press the ‘MEM’ button once, then press it again to
show the last measurement.
•The symbols for ‘EAR’ or ‘FOREHEAD’ will appear with each measurement
stored in memory to indicate whether a person’s forehead or ear
temperature was taken.
•Each press of the same button recalls a previous measurement.
Troubleshooting
Problem Checklist Countermeasure
No response/automatic
reset when pulling out
plastic insulator tab.
Batteries are low or dead
Batteries installed in
wrong polarity?
Poor battery contact?
Change to new
batteries
Remove batteries and
reinsert batteries
correctly
Measured temperature
is lower than
89.6°F/32.0°For higher
than 109°F/42.9°C
Follow steps in user
manual for correct
measurements.
Check the device is in
the correct operating
mode.
These Error messages
indicate a problem with
the hardware.
Contact Mobi
Technologies, Inc. via
contacting information
at the end of this
manual.
Operating Temperature is
out of the range
Use the thermometer in
the range of operating
conditions
The sensor temperature
has not been stabilized
Wait 10 seconds and
take a measurement
again.
The measurement is
not accurate or there is
doubt of measurement
results.
Check to see if the
infrared sensor is clean or
not.
Clean the infrared
sensor
with cotton swab
according to the user
manual.
Determine whether your
measuring method is
correct or not.
Please review the user
manual and ensure you
are operating the
thermometer correctly.
Assess whether you have
allowed the thermometer
and the patient to
become stabilized in the
room for 30 minutes.
Please ensure the
thermometer and
patient remain in the
location for at least 30
minutes before
recording a
temperature.
Are you using the
thermometer indoors or
outdoors.
Always do the
measurements indoors.
Determine if you might
have held the
thermometer in your
hand too long which may
affect its accuracy.
Place the thermometer
in the room where the
measurement is due to
be taken, let it stabilize
for 30 minutes before
use.
Check to see if the Low
Battery icon is showing on
the LCD screen.
Immediately replace the
batteries with new ones.
Product Safety & Warnings
WARNING:
WARNING:
WARNING:
WARNING:
WARNING:
WARNING:
This product was designed to measure human body
temperature on the forehead, do not use this for any other
purpose.
Do not use this thermometer if it has been malfunctioning or it
has been damaged.
This product is not waterproof. Do not use this product under
any wet conditions and do not immerse in any liquid or water.
This product should not be left alone with children or pets with
not in use by an adult.
Do not store the thermometer in extreme temperatures below
(-4°F / -20°C) or over (131°F/ 55°C).
Do not use the product in a wet ear canal after swimming or
bathing. It is possible to damage the ear canal.
Equipment Symbols
Warning Compliance with WEEE Standard
Non-Sterile
Packaging DO NO THROW AWAY intended
for multiple use
Refer to
Operating
Instructions
Operating atmospheric pressure
Operating
Temperature Serial number
Operating
Humidity Recyclable
Manufacturer This device compiles with Part 15
of FCC (federal communications
commission) rules.
IP22: The first number 2: Protected against solid foreign objects to
12.5mm Φ and greater. The second number: Protected against
vertically falling water drops, when enclosure titled up to 15°.
Limited Product Warranty
MOBI® warrants its products to be free from defects in material and
workmanship for period of (1 Year) from the date of purchase. Should the
product prove to be defective at any time during the warranty period, we would
either replace or repair the product at our option without charge. After the
warranty period, a service charge will apply for replacement of parts and labor
costs. To obtain warranty service, you must return the product complete with its
original parts & accessories along with a copy of the original purchase, gift or
registry receipt to us. This warranty does not cover damage caused by any
tampering, accident, misuse, abuse, improper maintenance, unauthorized
modification, or connection to an improper power supply. There will be a charge
for repair caused for such damage. This warranty excludes all incidental or
consequential damages and any liability other than stated above.
Questions?
Please visit: www.getmobi.com
Email: servic[email protected]
Note: For Detailed Instructional Manual please follow this link:
http://www.getmobi.com/users-manuals
© 2021 MOBI Technologies, Inc.
All Rights Reserved

This manual suits for next models

1

Other Mobi Technologies Thermometer manuals

Mobi Technologies 70125 User manual

Mobi Technologies

Mobi Technologies 70125 User manual

Mobi Technologies 70118 User manual

Mobi Technologies

Mobi Technologies 70118 User manual

Mobi Technologies FEVERTRACK User manual

Mobi Technologies

Mobi Technologies FEVERTRACK User manual

Mobi Technologies tempTalk User manual

Mobi Technologies

Mobi Technologies tempTalk User manual

Mobi Technologies PRIME User manual

Mobi Technologies

Mobi Technologies PRIME User manual

Mobi Technologies DualScan User manual

Mobi Technologies

Mobi Technologies DualScan User manual

Mobi Technologies DualScan prime User manual

Mobi Technologies

Mobi Technologies DualScan prime User manual

Mobi Technologies 70117 User manual

Mobi Technologies

Mobi Technologies 70117 User manual

Mobi Technologies DualScan Prime 3 User manual

Mobi Technologies

Mobi Technologies DualScan Prime 3 User manual

Mobi Technologies PRIME User manual

Mobi Technologies

Mobi Technologies PRIME User manual

Mobi Technologies BT-A13 User manual

Mobi Technologies

Mobi Technologies BT-A13 User manual

Mobi Technologies 700026 User manual

Mobi Technologies

Mobi Technologies 700026 User manual

Mobi Technologies 70119 User manual

Mobi Technologies

Mobi Technologies 70119 User manual

Mobi Technologies 70113 User manual

Mobi Technologies

Mobi Technologies 70113 User manual

Mobi Technologies HTD8813C User manual

Mobi Technologies

Mobi Technologies HTD8813C User manual

Popular Thermometer manuals by other brands

Microlife Aponorm FLEXIBLE ENTE manual

Microlife

Microlife Aponorm FLEXIBLE ENTE manual

TQC TE1005 instruction manual

TQC

TQC TE1005 instruction manual

SATO SK-8300 instruction manual

SATO

SATO SK-8300 instruction manual

LumaSense E2T PULSAR 4 quick start guide

LumaSense

LumaSense E2T PULSAR 4 quick start guide

Fluke 51 II Series Specifications

Fluke

Fluke 51 II Series Specifications

Maverick DT-12 Features & dimensions

Maverick

Maverick DT-12 Features & dimensions

Klein Tools IR07 instructions

Klein Tools

Klein Tools IR07 instructions

Maverick ET-75 Specification sheet

Maverick

Maverick ET-75 Specification sheet

VERTBAUDET IT-901 user manual

VERTBAUDET

VERTBAUDET IT-901 user manual

Oakton Acorn Temp TC specification

Oakton

Oakton Acorn Temp TC specification

ETI 810-275 operating instructions

ETI

ETI 810-275 operating instructions

Microlife NC 100 manual

Microlife

Microlife NC 100 manual

JOYTECH DET-1015b owner's manual

JOYTECH

JOYTECH DET-1015b owner's manual

Omega HH11B instruction sheet

Omega

Omega HH11B instruction sheet

Hanna Instruments HI 98701 instruction manual

Hanna Instruments

Hanna Instruments HI 98701 instruction manual

Martel 306 Dataloger instruction manual

Martel

Martel 306 Dataloger instruction manual

Physio Logic DiGiPro user guide

Physio Logic

Physio Logic DiGiPro user guide

Omega HH2001A operating instructions

Omega

Omega HH2001A operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.