PRIOR TO INSTALLATION:
Important: some options may slightly alter installation. To ensure proper installation review the manual thoroughly and verify
Rough-Ins before beginning work. File this manual with the owner or maintenance personnel upon completion of installation.
— Fixture mounting requirements: industry standard wall construction, adequate to support the fixture and installer provided
wall anchors sufficient to secure the fixture.
— Inspect fixture and all parts for damages.
IMPORTANT:
1. Waste P-Trap, Water Supply Service Angle Stop Valve and 2” x 4” Electrical Plug-In Receptacle to be supplied by others
in accordance with local codes. sed for the Waste Connection.A P-Trap (by others) must be u
2. Water supply is 3/8” Outside Diameter Copper Tube. Waste is 1-1/4” Outside Diameter.
3. Completely flush supply lines of all foreign debris before connecting to fixture. Drinking Fountain designed to not affect
taste, odor, color, or sediment. Optional water filter (WF1) is available should any of these problems arise from the water
supply.
4. If possible, limit exposure of the Drinking Fountain to direct sun light. The actual surface temperature of a Drinking
Fountain in direct sunlight on a 90°F day, the Drinking Fountain would be about 140°F.
2. Remove the bottom cover from the drinking fountain and set aside in a safe place. Save the screws in a secure location for
re-use in later stages of installation.
7. For outdoor installation, see outdoor installation instructions (Page 5)
3. Hang the Drinking Fountain on the Hanger Bracket, ensuring the Bracket Tabs engage AND seat in the slots in the back of
the drinking fountain. Verify Drinking Fountain is level, left to right AND front to back from bottom of unit.
NOTE: The Bubbler Stream may be adversely affected if unit is not square and level. Bottom of unit and louvers should be
used as reference to verify unit is square and plumb.
INSTALLATION:
4. Anchor Drinking Fountain to wall at other mounting points in base. Shim lower rear mounting points to level unit if
necessary.
9. Per UPC 609.10- All building water supply systems in which quick acting valves are installed shall be provided with
devices to absorb the Hammer caused by high pressure resulting from the quick closing of the valve. These pressure-
absorbing devices shall be approved mechanical devices. Water pressure-absorbing devices will be installed as close as
possible to the Quick Closing Valve.
5. Thoroughly flush the 3/8” O.D. Supply Line and then connect drinking fountain to water supply Angle Stop Valve (by others)
with supplied 3/8” O.D. copper tube.
7. Warranty is voided if installation is not made following current Murdock Mfg. installation instructions and if components
are assembled to the fixture that is not approved by Murdock Mfg.
5. Do NOT solder Copper Tube when inserted into the Coupler as damage to the O-Ring will result.
8. Fixture operates within water pressure range of 20 to 105 PSIG (138 to 724 kPa). Murdock Mfg. will not warranty fixtures
damaged when connected to supply lines with flow pressure lower than 20 PSIG (138 kPa) or higher than 105 PSIG (724
kPa). A pressure regulator must be furnished by others on supply line if inlet pressure is greater than 105 PSIG (724 kPa).
6. All burrs must be removed from outside of cut Tubes before inserting into Coupler or other components.
1. Mount Hanger Bracket to wall horizontally level as shown in Roughing-In and Dimensional Drawing. NOTE: Adjust height
of Bracket if Bubbler outlet height is required to vary from that shown /indicated. Hanger Bracket MUST be securely
anchored to wall with fasteners sufficient to support 3 times the weight of Water Cooler.
NOTE: If wall cannot provide adequate support, order and install optional fixture support carrier.
NOTE: If replacing a competitors Water Cooler you may be able to use existing mounting bracket.
6. Make up 1-1/4” O.D. Waste Connection for P-Trap (by others) .
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S