NI PXIe-8880 Owner's manual

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION
PXIe-8880
2.3 GHz Eight-Core PXI Express Controller
Read this document before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring
instructions in addition to requirements of all applicable codes, laws, and standards. Visit ni.com/manuals for more information about your product, including
specifications, pinouts, and instructions for connecting, installing, and configuring your system.
Icons
Notice Take precautions to avoid data loss, loss of signal integrity, degradation of performance, or damage to the product.
Caution Take precautions to avoid injury. Consult the product documentation for cautionary statements when you see this icon printed on the
product. Cautionary statements are localized into French for compliance with Canadian requirements.
Safety Guidelines
General Guideline (ALL SERIS)
Caution Observe all instructions and cautions in the user documentation. Using the product in a manner not specified can damage the product and
compromise the built-in safety protection.
Attention Suivez toutes les instructions et respectez toutes les mises en garde de la documentation d'utilisation. L'utilisation du produit de toute autre
façon que celle spécifiée risque de l'endommager et de compromettre la protection de sécurité intégrée.
Hot Surface Caution
Caution If the product has been in use, it may exceed safe handling temperatures and cause burns. Allow the product to cool before handling.
Attention Si le produit a été utilisé, il peut avoir atteint des températures trop élevées pour être manipulé en toute sécurité, ce qui peut provoquer des
brûlures. Laissez le produit refroidir avant de le manipuler.
mmWave Caution
Caution Product installation must adequately protect users' eyes from exposure to millimeter wave radiation output and input signals from the
transmitter and receiver.
Attention L'installation du produit doit permettre d'assurer une protection adéquate des yeux des utilisateurs contre l'exposition aux rayonnements
d'ondes millimétriques des signaux en entrée et en sortie provenant de l'émetteur et du récepteur.
Board-Only/Components Caution
Caution The product will need to be mounted in suitable Fire and Mechanical end product enclosure; Exercise caution when placing the product
inside an enclosure. Auxiliary cooling may be necessary to keep the product under the maximum ambient temperature rating for the product. Refer to
the product specifications for more information about the maximum ambient temperature rating.
Attention Le produit devra être monté dans un boîtier du produit final répondant aux exigences de résistance mécanique et de protection incendie ;
faites preuve de prudence lorsque vous placez le produit dans un boîtier. Un système de refroidissement auxiliaire peut être nécessaire pour maintenir le
produit en dessous de sa température nominale maximale. Reportez-vous aux spécifications du produit pour obtenir plus d'informations sur la
température nominale maximale.
Non-Hazardous Signals/Electric Shock Caution
Caution The product is designed for non-hazardous, live signals. You must ensure that all signals connected to the product are isolated from
hazardous, live circuits and no unsafe voltages are present at the inputs. Voltages that exceed the specifications could result in damage to the product or
electric shock.
Attention Le produit est conçu pour les signaux en direct non dangereux. Vous devez vous assurer que tous les signaux connectés au produit sont
isolés des circuits dangereux sous tension et qu'aucune tension dangereuse n'est présente aux entrées. Des tensions supérieures à celles mentionnées
dans les spécifications peuvent endommager le produit ou provoquer un choc électrique.

Power Requirements
Voltage (V) Current (Amps) Typical Current (Amps) Maximum
+3.3 V 2.24 A 2.96 A
+5 V 2.44 A 3.11 A
+12 V 6.5 A 8.7 A
5 VAUX 0.19 A 0.23 A
Physical
Board dimensions Four-wide 3U PXI Express module
Slot requirements One system slot plus three controller expansion slots
Compatibility Fully compatible with PXI Express Specification 1.0
Weight 1.5 kg (3.4 lb) typical
Environmental
Maximum altitude 2,000 m (800 mbar) (at 25 °C ambient temperature) with chassis fans on High.
Pollution Degree 2
Indoor use only.
Caution Clean the PXIe-8880 with a soft nonmetallic brush. Make sure that the device is completely dry and free from contaminants before returning
it to service.
Operating Environment
Caution The operating temperature must not be exceeded, even when used in a chassis with a higher temperature range.
Ambient temperature range 0 °C to 50 °C (See notes below.) (Tested in accordance with IEC-60068-2-1
and IEC-60068-2-2. Meets MIL-PRF-28800F Class 3 temperature limits,
except as noted.)
Relative humidity range 10% to 90%, noncondensing (Tested in accordance with IEC-60068-2-56.)
Notice Processor should not throttle CPU frequency under reasonable, worst case processor work loads at high operating temperatures. If you
experience CPU frequency variation, turn your chassis fans on High, using the fan speed selector switch on the rear of your chassis.
Notice 0 °C to 45 °C when used with the PXIe-1071, PXIe-1078 (with kit part number 158034A-01), or PXIe-1086 chassis.
Storage Environment
Ambient temperature range
Standard -40 °C to 71 °C (Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2.
Meets MIL-PRF-28800F Class 3 limits.)
Relative humidity range 5% to 95%, noncondensing (Tested in accordance with IEC-60068-2-56.)
Maintenance
Clean the PXIe-8880 with a soft nonmetallic brush. Make sure that the device is completely dry and free from contaminants before returning it to service.
2| ni.com | PXIe-8880 SERI

Shock and Vibration
Operating Shock 30 g peak, half-sine, 11 ms pulse in the Y and Z axes. 20 g peak, half-sine,
11 ms pulse in the X axis. (Tested in accordance with IEC-60068-2-27. Meets
MIL-PRF-28800F Class 2 limits in Y and Z axes.)
Random Vibration
Operating 5 to 500 Hz, 0.3 grms
Nonoperating 5 to 500 Hz, 2.4 grms (Tested in accordance with IEC-60068-2-64.
Nonoperating test profile exceeds the requirements of MIL-PRF-28800F, Class
3.)
Safety Compliance Standards
This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use:
• IEC 61010-1, EN 61010-1
• UL 61010-1, CSA C22.2 No. 61010-1
Notice For UL and other safety certifications, refer to the product label or the Product Certifications and Declarations section.
Electromagnetic Compatibility Standards
This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use:
• EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity
• EN 55011 (CISPR 11): Group 1, Class A emissions
• EN 55022 (CISPR 22): Class A emissions
• EN 55024 (CISPR 24): Immunity
• AS/NZS CISPR 11: Group 1, Class A emissions
• AS/NZS CISPR 22: Class A emissions
• FCC 47 CFR Part 15B: Class A emissions
• ICES-001: Class A emissions
Notice In the United States (per FCC 47 CFR), Class A equipment is intended for use in commercial, light-industrial, and heavy-industrial locations.
In Europe, Canada, Australia and New Zealand (per CISPR 11) Class A equipment is intended for use only in heavy-industrial locations.
Notice Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical equipment that does not intentionally generate radio frequency
energy for the treatment of material or inspection/analysis purposes.
Notice For EMC declarations and certifications, and additional information, refer to the Product Certifications and Declarations section.
CE Compliance
This product meets the essential requirements of applicable European Directives, as follows:
• 2014/35/EU; Low-Voltage Directive (safety)
• 2014/30/EU; Electromagnetic Compatibility Directive (EMC)
Product Certifications and Declarations
Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for NI
products, visit ni.com/product-certifications, search by model number, and click the appropriate link.
Environmental Management
NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous
substances from our products is beneficial to the environment and to NI customers.
For additional environmental information, refer to the Commitment to the Environment web page at ni.com/environment. This page contains the environmental
regulations and directives with which NI complies, as well as other environmental information not included in this document.
Waste Electrical and Electronic Equipment (WEEE)
EU Customers At the end of the product life cycle, all NI products must be disposed of according to local laws and regulations. For more
information about how to recycle NI products in your region, visit ni.com/environment/weee.
Battery Replacement and Disposal
Cd/Hg/Pb
Battery Directive This product contains a long-life coin cell battery. If you need to replace it, use the Return Material Authorization (RMA) process
or contact an authorized NI service representative. For more information about compliance with the EU Battery Directive 2006/66/EC about Batteries
and Accumulators and Waste Batteries and Accumulators, visit ni.com/environment/batterydirective.
PXIe-8880 SERI | © National Instruments Corporation | 3

电子信息产品污染控制管理办法(中国 RoHS)
540
e
NI 符合中国电子信息产品中限制使用某些有害物质指令(RoHS)。关于 NI 中国 RoHS 合规性信息,请登录 ni.com/
environment/rohs_china。(For information about China RoHS compliance, go to ni.com/environment/rohs_china.)
Additional Resources
Visit ni.com/manuals for more information about your device, including specifications, pinouts, and instructions for connecting, installing, and configuring
your system.
NI Services
Visit ni.com/support to find support resources including documentation, downloads, and troubleshooting and application development self-help such as
tutorials and examples.
Visit ni.com/services to learn about NI service offerings such as calibration options, repair, and replacement.
Visit ni.com/register to register your NI product. Product registration facilitates technical support and ensures that you receive important information updates
from NI.
NI corporate headquarters is located at 11500 N Mopac Expwy, Austin, TX, 78759-3504, USA.
Information is subject to change without notice. Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on NI trademarks. Other product
and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI products/technology, refer to the appropriate
location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can find information
about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS
TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained
in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014,
and DFAR 252.227-7015.
© 2020 National Instruments Corporation. All rights reserved.
377458A-01 October 14, 2020
Other manuals for PXIe-8880