921413000_09_008
Page 1 from 4
13,6-14,8V DC
6mA
Bayblend FR3010, clear polycarbonate (red)
USAGE
BATTERY TYPE
For external use
12V/1,3Ah Pb (sealed lead-acid) (not included)
IP20
115 dB / 1m
-10 60 C
o
έως
Up to 95%
2 years (6 months for A-989 battery)
1700gr.
290x95x190mm
BS-413
EN 50130-4, EN 55022, EN 60950-1
TECHNICAL CHARACTERISTICS
RELATIVE HUMIDITY
CONSTRUCTION MATERIAL
WEIGHT
EXTERNAL DIAMENSIONS
GUARANTEE
OPERATION VOLTAGE
QUIESCENT CONSUMPTION
SOUND LEVEL
PRODUCED IN ACCORDANCE WITH
OPERATION TEMPERATURE RANGE
DEGREES OF COVER PROTECTION
Autonomous electronic siren
with beacon for burglar alarm panels
GENERAL tampered with.
The BS-413 alarm siren is of robust design and If you require, the siren to also be activated if the
can be used with conventional burglar alarm siren is dismounted from the wall. you must
panels such as the BS-468. It has a red beacon connect the T1, T2 (TAMPER) inputs.
that blinks when the siren is activated and a In case of maintenance or if the siren is moved
piezo speaker that produces a sound level of from it’s mounting position, the SE (Service)
115dB at 1 meter.input of the siren must be connected to the (-) of
The incorporated tamper mechanism protects the panel and the panel must be set to OFF.
the siren from unauthorized access when the
cables are cut, the cover is removed or when Battery
the siren is unmounted from the wall. If the battery has not been connected then the
siren produces a single tone sound every 1
Mounting second.
It is mounted externally on a flat surface and at Whereas if the battery does not operate
a height of about 2,5 meters. Also it should be correctly, a 3 tone sound is emitted every 12
placed in an area that does not obstruct the hours.
sound.
Beacon
WARNING!!! There is a two position (ON, OFF) jumper on the
All 4 mounting screws must be used. siren which is marked (LED FLASΗ). If a link is
placed on the (ON) position, the beacon blinks
Connection every 4 seconds in the quiescent state. If no
The connection between the siren and the BS- jumper is placed then the beacon is OFF during
468 panel is shown on figure 1.the quiescent state and blinks during the alarm.
After finishing with the connections, connect the
battery cables, install the internal cover and the Start signal
front fascia of the siren by installing the screws There is also another 2 position jumper marked
on the bottom side. Finally remove the cable (TRIGGER) with the positions (-) and (+).
connected to the SE (Service) of the siren from This jumper sets if the trigger in positive or
the (-) of the panel. The siren will sound once to negative. Α positive trigger means that the ST
indicate that it is ready to operate and receive a (START) signal must be a positive voltage for
command from the panel. the siren to be activated.
The siren now charges the battery and is ready
to accept an ALARM signal from the panel or if
the cables are cut. If we connect the Τ1, Τ2
(TAMPER) signals then it will be activated if it is
Thank you for your trust in our products
Olympia Electronics - European manufacturer