manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Omron
  6. •
  7. Accessories
  8. •
  9. Omron E2K-F User manual

Omron E2K-F User manual

This manual suits for next models

4

Other Omron Accessories manuals

Omron SYSMAC C200H-IDS01-V1 User manual

Omron

Omron SYSMAC C200H-IDS01-V1 User manual

Omron Z4M-WR User manual

Omron

Omron Z4M-WR User manual

Omron E3M-V - User manual

Omron

Omron E3M-V - User manual

Omron F150-2 User guide

Omron

Omron F150-2 User guide

Omron E3X-DA-S User manual

Omron

Omron E3X-DA-S User manual

Omron E3MC - User manual

Omron

Omron E3MC - User manual

Omron F10 User manual

Omron

Omron F10 User manual

Omron E2C-CR5B User manual

Omron

Omron E2C-CR5B User manual

Omron E3S-C - User manual

Omron

Omron E3S-C - User manual

Omron SYSMAC C200H-IDS01-V1 User manual

Omron

Omron SYSMAC C200H-IDS01-V1 User manual

Omron F3S-TGR-CL_B User manual

Omron

Omron F3S-TGR-CL_B User manual

Omron FQ-AC Series User manual

Omron

Omron FQ-AC Series User manual

Omron ZW-XC7 User manual

Omron

Omron ZW-XC7 User manual

Omron ZFV-LTF01 User manual

Omron

Omron ZFV-LTF01 User manual

Omron E3X-NA - User manual

Omron

Omron E3X-NA - User manual

Omron V680-HAM91 User manual

Omron

Omron V680-HAM91 User manual

Omron E3F User manual

Omron

Omron E3F User manual

Omron F160 Vision Sensor User manual

Omron

Omron F160 Vision Sensor User manual

Omron LASER ZX - User manual

Omron

Omron LASER ZX - User manual

Omron ZFV-SC90 Series User manual

Omron

Omron ZFV-SC90 Series User manual

Omron E3FZ-B User manual

Omron

Omron E3FZ-B User manual

Omron E3K User manual

Omron

Omron E3K User manual

Omron ZFV-CA40 User manual

Omron

Omron ZFV-CA40 User manual

Omron ZX2-LDA User manual

Omron

Omron ZX2-LDA User manual

Popular Accessories manuals by other brands

Quincy lab 140AE-1 operating manual

Quincy lab

Quincy lab 140AE-1 operating manual

HomePro ZIR000 user manual

HomePro

HomePro ZIR000 user manual

DOL 20SCR Technical user guide

DOL

DOL 20SCR Technical user guide

RAB Smart Task installation manual

RAB

RAB Smart Task installation manual

Kemppi KMS 300 quick guide

Kemppi

Kemppi KMS 300 quick guide

Stearns 57,500 Series Installation and service instructions

Stearns

Stearns 57,500 Series Installation and service instructions

iGuzzini TWILIGHT COPENAGHEN manual

iGuzzini

iGuzzini TWILIGHT COPENAGHEN manual

Adelaide Annexe & Canvas Avan Deluxe installation guide

Adelaide Annexe & Canvas

Adelaide Annexe & Canvas Avan Deluxe installation guide

OHAUS 5000 instruction manual

OHAUS

OHAUS 5000 instruction manual

HOME8 WLS1300 quick start guide

HOME8

HOME8 WLS1300 quick start guide

MAXBOTIX MaxSonar quick start guide

MAXBOTIX

MAXBOTIX MaxSonar quick start guide

ioSmart iSmart56 Installation and user guide

ioSmart

ioSmart iSmart56 Installation and user guide

Focusrite Scarlett 18i8 user guide

Focusrite

Focusrite Scarlett 18i8 user guide

Velleman ED38105 user manual

Velleman

Velleman ED38105 user manual

JumpSport SkyBounce user manual

JumpSport

JumpSport SkyBounce user manual

Prima-Temp PRIYA Instructions for use

Prima-Temp

Prima-Temp PRIYA Instructions for use

Tefcold BC85I-BC85I W user manual

Tefcold

Tefcold BC85I-BC85I W user manual

Vaisala WMS302 user guide

Vaisala

Vaisala WMS302 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

D-189E2K-F
E2K-F
Flat Type Capacitive Proximity Sensor
E2K-F
Low-profiled Capacitive
Proximity Sensor providing
Flexible Installation
Ordering Information
Rating/Performance
Shape Sensing distance Output specifications Operating status Model
DC 3-wire NPN
NO
E2K-F10MC1
NC
E2K-F10MC2
NO
E2K-F10MC1-A
NC
E2K-F10MC2-A
Item E2K-F10MC1
E2K-F10MC2
E2K-F10MC1-A
E2K-F10MC2-A
Sensing distance 10 mm ±10% 4 to 10 mm ±10%
Setting distance 0 to 7.5 mm
Differential distance 15% max. sensing distance
Sensing object Conductors and dielectrics
Standard sensing object with grounded metal: 50 x 50 x 1 mm
Response frequency 100 Hz
Rated supply voltage
(operating voltage) 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Current consumption 10 mA max. (24VDC)
Control
output
Switching capacity NPN open collector 100 mA max. (under 30 VDC)
Residual voltage 1.5 V max. (under load current of 100 mA with cable length of 2 m)
Indicator lamp Detection indicator (red LED)
Operating status (with sensing
object approaching) NO
Protective circuits Reverse connection protection, surge absorber
Ambient temperature Operating/Storage: -10°C to 55°C (with no icing or condensation)
Ambient humidity Operating/Storage: 35% to 95%RH
Temperature influence ±15% max. of sensing distance at 23°C within the temperature range of -10°C and 55°C
Voltage influence ±2.5% max. of sensing distance within a range of ±10% of rated supply voltage
Insulation resistance 50 M min. (at 500 VDC) between energized parts and case
Dielectric strength 500 VAC 50/60 Hz for 1 min between energized part and case
Vibration resistance Malfunction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s2for 3 times each in X, Y, and Z directions
Protective structure IEC 60529 IP66 IEC 60529 IP64
Connection method Pre-wired models (standard length: 2 m)
Weight (Packed state) Approx. 35 g
Material Case Heat-resistant ABS resin
Sensing surface
Accessories Instruction manual
Flat type
Unshielded
10 mm
4 to 10 mm
F502-EN2-04.book Seite 189 Dienstag, 26. Juli 2005 5:48 17
D-190 Capacitive Sensors
Precautions
Design
Sensing Object Material
E2K-F can detect almost any type of object. The sensing dis-
tance of E2K-F, however, will vary with the electrical charac-
teristics of the object, such as the conductance and
inductance of the object, as well as the water content and ca-
pacity of the object. The maximum sensing distance of E2K-F
will be available if the object is made of grounded metal.
There are objects that cannot be detected indirectly. There-
fore test E2K-F in a trial operation with the objects before us-
ing E2K-F in actual applications.
Effects of Surrounding Metal
Separate E2K-F from ambient metals as shown below.
Mutual Interference
If installing more than one E2K-F face to face or side by side,
separate them as shown below.
Effect of High-frequency Electro-magnetic Field
E2K-F may malfunction if an ultrasonic washer, high-frequen-
cy generator, transceiver, or inverter are nearby.
For a typical measure, refer to the "Noise" with Common pre-
cautions of a photoelectric sensor in Rear B-page.
Wiring Considerations
The characteristics of E2K-F will not change if the cord is ex-
tended. Keep in mind that voltage drops may occur due to the
cord extension, thus, ensure that the total cord length does
not exceed 200 m.
Characteristic data (typical)
Sensing Distance vs. Sensing Object
Grounded metal (t=1)
Ungrounded metal (t=10)
Glass
(t=10) Phenol resin
(t=10)
10
9
8
7
6
5
4
3
2
1
0 1020 304050 607080
Sensing object size (mm)
Sensing distance X (mm)
Output Circuit Diagram
Operating
Chart
Output circuit
Yes
No
ON
OFF
ON
OFF
Operation indicator
(red)
Sensing object
Output transistor
(load)
NO Type
100W
Brown
Brack
Output
Blue
+V
0V
Load
Main
circuit
* 100 mA max. (load current)
*
Correct Use
60mm
Metal object
45mm
30mm
Metal object Metal object
40mm
50mm 50mm
Close mounting possible Face-to-face mounting
F502-EN2-04.book Seite 190 Dienstag, 26. Juli 2005 5:48 17
D-191E2K-F
E2K-F
Dimensions (Unit: mm)
E2K-F
5
10.1
20 5
10
*
50 42 34
8
Operation indicator
(red)
Two, 3.5 dia.
Two, 3.5 dia.
42±0.2
* 2.9-dia. three conductors vinyl-insulated round cable
(cross-sectional area of conductors: 0.14 mm
2
;
insulation diameter: 0.9 mm)
Standard length: 2 m
Mounting Holes
F502-EN2-04.book Seite 191 Dienstag, 26. Juli 2005 5:48 17
D-192 Capacitive Sensors
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. D018-E2-02A-X
F502-EN2-04.book Seite 192 Dienstag, 26. Juli 2005 5:48 17