F3SS
G-75F3SS
Rating/performance
Wiring
Wire the F3SS only after all power has been turned off.
Emitter Receiver
Note: Ground the emitter and receiver to the ground terminal inside the case.
Item Model F3SS-AT60P
Sensing distance 0.3 to 60 m
Number of optical
axes 1 (single beam)
Beam diameter 31 mm
Min. sensing object Opaque object, 31-mm dia. or greater
Orientation angle emitter/receiver: ±2.5° or less each (based on IEC61496-2 at detection distance of 3 m or greater)
Light source
(wave length) Infrared LED (880 nm)
Power supply voltage 24 V DC ±10%, ripple (p-p) 5% or less
After power is turned on
Startup time 4 s or less
Current consumption Emitter: 170 mA or less, receiver: 800 mA or less (including load output current)
Operating mode Auto start mode, start interlock mode, and start/restart interlock mode can all be selected using a switch in the
receiver.
Control output PNP transistor outputs x 2 outputs, load current 250 mA or less (residual voltage 1 V or less) (excluding voltage
drop due to cable extension), Light ON
Protective circuits Output load short circuit and power supply reverse connection protection
Response time
(ON→OFF) 35 ms max.
Ambient temperature Operating/Storage: 0°C to 55°C (with no icing or condensation)
Ambient humidity Operating/Storage: 35% to 95% RH (no condensation)
Vibration resistance Malfunction/durability: 10 to 50 Hz, amplitude 0.7 mm, 20 sweeps each in X, Y, and Z directions
Shock resistance Malfunction/durability: 100 m/s2, 1,000 times each in X, Y, and Z directions
Protective structure IEC60529 Standard IP65
Connection method Connect to terminal block on internal board
Weight (Packed state) 2.5 kg
Materi-
al
Case Aluminum
Cap Aluminum
Accessories Set of mounting brackets, operation manual, caps for unused conduits
Applicable standards IEC (EN) 61496-1 TYPE4 ESPE *1 IEC61496-2 TYPE4 AOPD *2
*1) ESPE (Electro-Sensitive Protective Equipment)
*2) AOPD (Active Opto-electronic Protective Devices)
Terminal
block
number
Terminal
name Functions Terminal block assignments
J3
+24 VDC +DC24V
RTN 0V (GND) RTN +
24VDC
Terminal
block
number
Terminal
name Functions Terminal block assignments
J5
1Control out-
put 1 (+)
2For control out-
put 1/2 COM (-)
3Control output 2
(+)
4 START(-)
5START(+)
6 +DC24V
7 0V (GND)
1234567