H7BR
H7BR
3
Supply voltage 100 to 240 VAC, 50/60 Hz or 24 VAC/12 to 24 VDC (permissible ripple: 20% max.)
Operating voltage range 85% to 110% of rated voltage
Power consumption Approx. 10 VA at 50 Hz, 240 VAC, 6 W at 24 VDC (approx. 8 A surge current for 2 ms
upon power application)
Max. counting speeds (CP1, CP2) 30 cps, or 1, 5, or 10 kcps (separate setting for CP1 and CP2)
Compensation and gate inputs Set to the faster of the CP1 or CP2 max. counting speed
Reset Min. pulse width for external reset: 1 or 20 ms, also manual reset
Batch count reset Min. pulse width: 20 ms
Key protect Response time: 1 second
One-shot output 10, 50, 100, 200, 500, or 1,000 ms (separate settings for presets 1 and 2)
Inputs (count, compensation, No-voltage inputs ON impedance: 1kΩmax. (approx. 2 mA when 0 kΩ)
reset, batch count reset, gate) ON residual voltage: 2 V max.
OFF impedance: 100 kΩmin.
Voltage inputs High level: 4.5 to 30 VDC
Low level: 0 to 2 VDC
Input resistant: Approx. 4.7 kΩ
Key protect input No-voltage input ON impedance: 1 kΩmax. (approx. 2 mA when 0 kΩ)
ON residual voltage: 1 V max.
OFF impedance: 100 kΩmin.
Control outputs Contacts: 3 A, 250 VAC, resistive load (p.f. = 1)
Transistor: Open collector; 100 mA at 30 VDC max. residual voltage 2 V max. (approx. 1 V)
Power supply for externally 12 VDC 160 mA, ±10% (5% ripple max.)
24 VDC 80 mA, ±10% (5% ripple max.)
Approvals UL/CSA/CE (EMC)
Ambient operating temperature -10°to 55°C (14°to 131°F) (with no icing)
Storage temperature -25°to 65°C (-13°to 149°F) (with no icing)
Ambient operating humidity 35% to 85% RH
■RATINGS
Output Description Applicable
mode Single preset counter Double preset counter counter series
N Sustained output Sustained output 2, selectable sustained or one-shot output 1 H7BR-B
F Sustained output, overrun display Sustained output 2, selectable sustained or one-shot output 1 H7BR-B
C One-shot output One-shot output 2, selectable one-shot or sustained output 1 H7BR-B
R One-shot output, overrun display One-shot output 2, selectable one-shot or sustained output 1 H7BR-B
K One-shot output One-shot output 2, selectable one-shot or sustained output 1 H7BR-B
P One-shot output One-shot output 2, selectable one-shot or sustained output 1 H7BR-B
Q One-shot output, overrun display One-shot output 2, selectable one-shot or sustained output 1 H7BR-B
A One-shot output One-shot output 2, selectable one-shot or sustained output 1 H7BR-B
D Instantaneous output, Instantaneous outputs when count value = preset H7BR-C
count value = preset
L Sustained output, count value ≥preset Sustained output 2, count value ≥preset, H7BR-C
Sustained output 1, count value ≤preset
H Sustained output, count value ≥preset Sustained outputs when count values ≥preset H7BR-C
K One-shot output, count value = preset One-shot outputs, count value = preset H7BR-C
■OUTPUT MODES SUMMARY