Omron F3EM User manual

1F3EM Measuring lightcurtain in robust aluminium housing
Measuring lightcurtain in robust aluminium housing
F3EM
Measuring lightcurtain
in robust aluminium
housing
The F3EM provides easy to install and set
up height and profile measurement. The
analog output provides a simple overall
height detection and the serial output mod-
els provide single beam evaluation for pro-
file measurements.
• Robust aluminium housing
• Analog output for simple height detections
• Serial output with single beam evaluation
for profile measurement
Ordering Information
Lightcurtain accessories
Sensor
type
Measurement
range (MaxM)Pitch1
1Models with 7.5 mm pitch are available. Contact your OMRON representative.
Sensing
distance
Chan-
nels
Connection method Order code
Analog output RS232 output2
2Models with RS485 serial output are available. Contact your OMRON representative.
Through-
beam
(measur-
ing)
150 5 mm 3 m 30 – 5 pin – – F3EM-005-150-AV F3EM-005-150-D2
18 mm 15 m 8 – – – F3EM-018-150-AV F3EM-018-150-D2
300 5 mm 3 m 60 – – – F3EM-005-300-AV F3EM-005-300-D2
18 mm 15 m 16 – – – F3EM-018-300-AV F3EM-018-300-D2
600 5 mm 3 m 120 – – – F3EM-005-600-AV F3EM-005-600-D2
18 mm 15 m 32 – – – F3EM-018-600-AV F3EM-018-600-D2
900 5 mm 3 m 180 – – – F3EM-005-900-AV F3EM-005-900-D2
18 mm 15 m 48 – – – F3EM-018-900-AV F3EM-018-900-D2
2000 5 mm 3 m 400 – – – – F3EM-005-2000-D2
2100 18 mm 15 m 112 – – – F3EM-018-2100-AV F3EM-018-2100-D2
Shape Type Comment Order Code
Laser alignment kit snap-on Laser beam generator and level F39-TGR-LLK2-SB
Protective tube for F3ET-_ -150 F3ET-IP150
for F3ET-_ -300 F3ET-IP300
for F3ET-_ -600 F3ET-IP600
for F3ET-_ -900 F3ET-IP900

2F3EM Measuring lightcurtain in robust aluminium housing
Rating/Specifications
Item Through-beam
F3EM-005_ F3EM-018_
Sensing distance 0 to 3 m 0 to 15 m
Vertical measurement range 0 to MaxMmm; MaxM: 150, 300, 600, 900,
20001
1Models with different measurement ranges between 150 mm and 2000 mm are available in 50 mm intervals. Please note that measurement
ranges between 1000 mm and 2000 mm are only available for serial output models.
0 to MaxMmm; MaxM: 150, 300, 600, 900,
21002
2Models with different measurement ranges between 150 mm and 2100 mm are available in 150 mm intervals.
Minimum detectable object size 10 mm 30 mm
Pitch 5 mm 18 mm
Control
output
Analog models 0-10 VDC, max. load current 30 mA
Serial models RS 232
Response time Analog output: 5 ms + 0,18 x channels; Serial output: 4.5 ms + 0.38 x channels at 4800 bps
Light source (wave length) Infrared LED (950 nm)
Power supply voltage 24 VDC ±10%
Ambient temperature 0 to 50°C
Degree of protection IEC 60529 IP65
Dimensions (see also page 4) 35 x 45 x (55 + 1.06 x MaxM) mm 35 x 45 x (55 + 0.98 x MaxM) mm
Material Case Aluminium
Cover Polycarbonate

3F3EM Measuring lightcurtain in robust aluminium housing
Output circuits
Type Output circuit
Receiver analog output
Connector pin arrangement
Receiver serial output
Connector pin arrangement
Emitter
Connector pin arrangement
Note: Terminal 2, 4 and 5 are not used
24 VDC
0 V
Brown
Grey
White
0-10 V
Black
Blue
1
5
2
4
3
Main
circuit
D/A
Converter
Out OFF
(red)
Out ON
(green)
Run OK
(yellow)
Power
(green)
Near/Far
(yellow)
+
-
2
34
1
5
24 VDC
0 V
Brown
Grey (Strobe Input)
Black RxD
Blue
1
5
2
4
3
Main
circuit
Out OFF
(red)
Out ON
(green)
Run OK
(yellow)
Power
(green)
Near/Far
(yellow)
White TxD
2
34
1
5
24 VDC
0 V
Brown
Blue
1
3
Main
circuit
Status OK
(yellow)
Power
(green)
2
34
1
5

4F3EM Measuring lightcurtain in robust aluminium housing
Dimensions
Operation
The F3EM measuring lightcurtain features optical synchroniza-
tion. This function is provided by the upper beam located on the
opposite side of the connector (see illustration below). During op-
eration this beam must always be kept free. Otherwise it will result
a loss of synchronism between the transmitter and receiver.
For applications where all beams are interrupted there are special
models with synchronization by wire. Please contact your
OMRON representative.
Indicator LEDs
For functions of indicator LEDs please refer to the tables be-
low:
Selector switches (dip switches)
Operation mode, distance setting (analog models) and trans-
mission speed (serial models) can be changed by selector
switches. To access selector switches unscrew the end cap
of the receiver unit:
Note: Selector setting must only be carried out when the receiver is not con-
nected to the power supply.
10
L
S
43
12
45 mm
35 mm
Item number Sensing area
S (mm)
Total length
L (mm)
F3EM-005-150-_ 159 225
F3EM-018-150-_ 147 213
F3EM-005-300-_ 318 384
F3EM-018-300-_ 294 360
F3EM-005-600-_ 636 702
F3EM-018-600-_ 588 654
F3EM-005-900-_ 954 1020
F3EM-018-900-_ 882 948
F3EM-005-2000-D2 2120 2186
F3EM-018-2100-_ 2058 2124
SYNCHRONISM
S: Sensing area
D: Pitch
DS
Name of indicator Colour
Power Green
Run ok Yellow
Out on Green
Out off Red
Near/Far Yellow
Name of indicator Colour
Power Green
Status ok Yellow
M12

5F3EM Measuring lightcurtain in robust aluminium housing
Analog Output Models (F3EM-_-AV)
DIP Switch Settings
If F3EM is operated in a distance < 1m, the sensitivity can be
set to NEAR operation. This could be necessary, if multiple
light curtains are installed close to each other, or if the light
curtain detects semi-transparent objects.
The analog output can operate either in STANDARD mode or
INVERTED mode:
• STANDARD mode: 0 V (if no beams is interrupted) to 10 V
(if all beams are interrupted)
• INVERTED mode: 10 V (if no beams is interrupted) to 0 V
(if all beams are interrupted)
Please find the DIP switch setting below:
Analog output value
The output value is related linear to the number of beams in-
terrupted by the object to be measured. For STANDARD
mode:
Output voltage = (10/ n° of optical units) * n° of interrupted
beams [VDC]
If multiple objects are inside the sensing area, the system will
read the total number of beams interrupted accordingly. Re-
ferring to the illustration below, the F3EM provides an output
signal in proportion with the sum of A+B:
Serial Output Models - RS232 (F3EM-_-D2)
The RS232 serial interface of F3EM is specified as follows:
• Full duplex operation
• Data format: 8-N-1 (bit start - 8-bit data - 1-bit stop - no
parity)
Transmission speed setting (Baud Rate)
The baud rate can be set by DIP switch 1 and 2.
@The baud rate must be set both on the receiver bar
dip-switches as well as the transmitter bar dip-switch-
es to align the timing synchronism of the two bars.
Communication protocol
The communication of serial interface provides two possible
operation modes:
• Command-response
• Triggered by external input
A) In command-response mode the command is 1 byte:
Command (hexadecimal) = 'BF'
The light curtain responds with a fixed number of bytes de-
pending on the number of light beams.
E.g. the response of a light curtain with 20 beams is 3 bytes:
The response bytes are composed by each bit representing
the status of each beam in the order as in the example above.
Remaining unused bits in the last byte are set to zero.
Each bit signals:
0 = BEAM NOT INTERUPTED
1 = BEAM INTERRUPTED
This drawing shows how the beams
are numbered on the light curtain
As a result each response byte contains 8 beams. The follow-
ing formula applies for the calculation if the number of re-
sponse bytes:
number of bytes = INT (number of optical units + 7) / 8)
The maximum number of optical beams that can be managed
is 400.
B) Trigger by external input
Alternatively the response can be forced by signal on the
STROBE input (PNP logic); the light curtain responds on the
serial line with the same protocol explained above.
Measurement method
In order to avoid missing information the light curtain stores in-
terruption of beam signals until the status is sent in the next
protocol response. After the response is sent the interruption
status is reset (all bits to zero).
The beams are scanned sequentially. Therefore it can occur
that a command or trigger arrives before the scan is complet-
ed. In this case the scan is interrupted and the status of the
scan before is transferred in the response protocol.
Switch
1 2 3 4
not used
not used
Distance setting (NEAR
position recommended if
distance is <1 m
Operation mode
ON NEAR ON DECREASING
OFF FAR (default) OFF INCREASING
(default)
DIP Switch 1 DIP Switch 2 Baud Rate (bps)
OFF OFF 4800
OFF (default) ON (default) 9600 (default)
ON OFF 19200
ON ON 38400
B
A
1st
byte
87654321
2nd
byte
16 15 14 13 12 11 10 9
3rd
byte
0 0 0 0 20191817

6F3EM Measuring lightcurtain in robust aluminium housing
Mounting
Mechanical attachment and alignment
Standard Mounting Bracket (provided with the sensor)
When the mounting bracket is attached to the surface, the mounting
screws can be inserted into the mounting rail of the light curtain. This
allows a vertical position adjustment.
Adjustable Mounting Bracket
Order separately under: F39-TGR-ST-ADJ
For adjustment of the optical axis angle, the adjustable mounting
bracket allows a turning of the light curtain.
Laser Alignment
Order separately under: F39-TGR-LLK2-SB
The laser alignment kit can be snapped onto the light curtain and
emits a high visibility laser beam for ensuring the optimal optical axis
angle adjustment.
Cable connectors
For pin arrangement and connecting the wires refer to Output Circuits.
Size Shape Type Features
Material Order code
Nut Cable
M12 General purpose
(screw)
5 wire Brass (CuZn) PVC 2M XS2F-M12PVC5S2M XS2F-M12PVC5A2M
PUR 2M XS2F-M12PUR5S2M XS2F-M12PUR5A2M

7F3EM Measuring lightcurtain in robust aluminium housing
Precautions
Power Supply Voltage and
Output Load Power Supply Voltage
Do not connect an AC power supply to the Sensor. If AC pow-
er (100 VAC or more) is supplied to the Sensor, it may ex-
plode or burn. Make sure that the power supply to the Sensor
is within the rated voltage range. If a voltage exceeding the
rated voltage range is supplied to the Sensor, it may explode
or burn.
Operating Environment
Do not use the sensor in locations with explosive or flamma-
ble gas. Make sure that the product is operated in accordance
with IP65 standards.
Do not subject the sensor to excessive shock when mounting.
When you use the sensor in the vicinity of an inverter motor,
be sure to connect the protective earth ground wire of the mo-
tor to earth. Failure to ground the motor may result in malfunc-
tion of the sensor.
Mounting the Sensor
Do not strike the sensor with a hammer or any other tool dur-
ing the installation of the Sensor.
Cleaning
Never use paint thinners or other organic solvents to clean the
surface of the product
M12 Connector
Always turn OFF the power supply to the sensor before con-
necting or disconnecting the metal connector. Hold the con-
nector cover to connect or disconnect it.
Secure the connector cover by hand. Do not use pliers; other-
wise the connector may be damaged.
If the connector is not connected securely, it may be discon-
nected by vibration or the proper degree of protection of the
sensor may not be maintained.
@WARNING
The F3EM multi-beam photoelectric sensor with beam
evaluation function is not a safety component for en-
suring the safety of people which is defined in EC di-
rective (2006/42/EC) or by any other regulations or
standards.

8F3EM Measuring lightcurtain in robust aluminium housing
In the interest of product improvement, specifications are subject to change without notice.Cat. No. E62E-EN-01A
OMRON EUROPE B.V.
Wegalaan 67-69,
NL-2132 JD, Hoofddorp,
The Netherlands
Phone: +31 23 568 13 00
Fax: +31 23 568 13 88
www.industrial.omron.eu
This manual suits for next models
19
Table of contents
Other Omron Measuring Instrument manuals

Omron
Omron K3NP User manual

Omron
Omron G9SX Series User manual

Omron
Omron K6CM series User guide

Omron
Omron K3NC User manual

Omron
Omron K3MA-L User manual

Omron
Omron H7CC-A Series User manual

Omron
Omron Z500 Series User manual

Omron
Omron K7DD User manual

Omron
Omron K3MA-J Series User manual

Omron
Omron M16 - User manual
Popular Measuring Instrument manuals by other brands

PERFECTPASS
PERFECTPASS PRECISION STAR installation instructions

R&S
R&S SMB100A Release notes

GREISINGER
GREISINGER GMI 15 operating manual

Enerpac
Enerpac EDI62 Series instruction manual

ABLE
ABLE VEGA VEGAFLEX 66 Installation & maintenance instructions

Endress+Hauser
Endress+Hauser PROline promag 53 operating instructions