Omron M16 - User manual

Indicator M16 G-127
Pushbutton
Switches
Indicator
M16
Cylindrical 16-dia. Indicator
• Same basic design as the A16 Pushbutton Switch.
• UL and cUL approved (File No. E41515).
Model Number Structure
■Model Number Legend
Completely Assembled
The model numbers used to order sets of Units are illustrated below. One set comprises the Display, Case, Lamp, and Socket.
(1) (2) (3) (4)
5
R
G
Y
PY
W
A
(5)
J
A
T
3J
BA
P
S
IP40
M 1 6 5 - T R - 24D - P
(1) Degree of Protection
Symbol Protection
IP65 oil-resistant
(3) Color of Display
Symbol Color
Red
Green
Yellow
Pure yellow
White
Blue
(2) Shape of Display
Symbol Shape
Rectangular
Square
Round
Rectangular (3-way guard)
Square (24-mm square)
(5) Terminal Type
Symbol Terminal type
PCB terminals
Screw-Less Clamp
(4) Light Source
Voltage Reduction Unit (24-V Built-in LED)
LED
Solder terminals are available only with 100-V models.
No symbol
No symbol Solder terminals
LED
Symbol Type Operating voltage Rated voltage
Incandescent
lamp
Symbol Type Operating voltage Rated voltage
The Voltage Reduction Unit is not available for models with
PCB terminals.
5 5 VAC/VDC 6 VAC/VDC
12 12 VAC/VDC 14 VAC/VDC
24 24 VAC/VDC 28 VAC/VDC
5D 5 ±5% VDC 5 VDC
12D 12 ±5% VDC 12 VDC
24D 24 ±5% VDC 24 VDC
T1 90 to 121 VAC/VDC 110 VAC/VDC
T2 180 to 242 VAC/VDC 220 VAC/VDC

G-128 Indicator M16
Ordering Information
■List of Models
Ordering as a Set
The model numbers used to order sets of Units are given in the following tables. One set comprises the Display, Case, Lamp, and Socket.
M16@-J (Rectangular) Models
Solder Terminal Models
M16@-A (Square) Models
Solder Terminal Models
M16@-T (Round) Models
Solder Terminal Models
Note: Enter the desired color symbol for the Display in @.
Appearance Lighting Operating voltage IP40 IP65 oil-resistant Display color symbol
(See note.)
LED without Voltage
Reduction Unit
5 VDC M16-J@-5D M165-J@-5D R: red
Y: yellow
G: green
A: blue
W: white
PY: Pure yellow
12 VDC M16-J@-12D M165-J@-12D
24 VDC M16-J@-24D M165-J@-24D
Incandescent lamp 5 VDC/VAC M16-J@-5 M165-J@-5
12 VDC/VAC M16-J@-12 M165-J@-12
24 VDC/VAC M16-J@-24 M165-J@-24
Appearance Lighting Operating voltage IP40 IP65 oil-resistant Display color symbol
(See note.)
LED without Voltage
Reduction Unit
5 VDC M16-A@-5D M165-A@-5D R: red
Y: yellow
G: green
A: blue
W: white
PY: Pure yellow
12 VDC M16-A@-12D M165-A@-12D
24 VDC M16-A@-24D M165-A@-24D
Incandescent lamp 5 VDC/VAC M16-A@-5 M165-A@-5
12 VDC/VAC M16-A@-12 M165-A@-12
24 VDC/VAC M16-A@-24 M165-A@-24
Appearance Lighting Operating voltage IP40 IP65 oil-resistant Display color symbol
(See note.)
LED without Voltage
Reduction Unit
5 VDC M16-T@-5D M165-T@-5D R: red
Y: yellow
G: green
A: blue
W: white
PY: Pure yellow
12 VDC M16-T@-12D M165-T@-12D
24 VDC M16-T@-24D M165-T@-24D
Incandescent lamp 5 VDC/VAC M16-T@-5 M165-T@-5
12 VDC/VAC M16-T@-12 M165-T@-12
24 VDC/VAC M16-T@-24 M165-T@-24

Indicator M16 G-129
Pushbutton
Switches
Ordering Individually
Displays, Cases, Lamps, and Sockets can be ordered separately. Combinations that are not available as sets can be created using individual parts.
Also, store the parts as spares for maintenance and repairs.
Note: Socket Units, which are combinations of Lamps and Sockets, are also available.
Display (Refer to page 130.)
Rectangular Square Round
Note: Use IP40 Displays in combination with IP40 Sock-
ets and use IP65 Displays in combination with IP65
Sockets.
Case (Refer to page 131.)
Lamp (Refer to page 130.)
Socket (Refer to page 131.)
Note: Display Units, which are combinations of
Displays and Cases, are also available.
Lighted Models
LED Incandescent Lamp Neon Lamp
Solder Terminals
(Without Voltage Reduction Unit)

G-130 Indicator M16
Display
For LED-lighted Models
Incandescent Lamps (With the exception of green, the Units are the same as for LEDs.)
Neon Lamps
Lamp
LED
Note: Use the white LED when the required illumination color is white or pure yellow.
Incandescent Lamp
Sealing IP40 IP65 oil-resistant
Appearance
Color of Display
Red A16L-JR A16L-AR A16L-TR A165L-JR A165L-AR A165L-TR
Yellow A16L-JY A16L-AY A16L-TY A165L-JY A165L-AY A165L-TY
Pure yellow A16L-JPY A16L-APY A16L-TPY A165L-JPY A165L-APY A165L-TPY
Green A16L-JGY A16L-AGY A16L-TGY A165L-JGY A165L-AGY A165L-TGY
White A16L-JW A16L-AW A16L-TW A165L-JW A165L-AW A165L-TW
Blue A16L-JA A16L-AA A16L-TA A165L-JA A165L-AA A165L-TA
Sealing IP40 IP65 oil-resistant
Appearance
Color of Display
Red A16L-JR A16L-AR A16L-TR A165L-JR A165L-AR A165L-TR
Yellow A16L-JY A16L-AY A16L-TY A165L-JY A165L-AY A165L-TY
Pure yellow A16L-JPY A16L-APY A16L-TPY A165L-JPY A165L-APY A165L-TPY
Green A16L-JG A16L-AG A16L-TG A165L-JG A165L-AG A165L-TG
White A16L-JW A16L-AW A16L-TW A165L-JW A165L-AW A165L-TW
Blue A16L-JA A16L-AA A16L-TA A165L-JA A165L-AA A165L-TA
Rectangular Square Round Rectangular Square Round
Rectangular Square Round Rectangular Square Round
Sealing IP40 IP65 oil-resistant
Appearance
Color of Display
Red A16L-JRN A16L-ARN A16L-TRN A165L-JRN A165L-ARN A165L-TRN
Green A16L-JGN A16L-AGN A16L-TGN A165L-JGN A165L-AGN A165L-TGN
White A16L-JWN A16L-AWN A16L-TWN A165L-JWN A165L-AWN A165L-TWN
Rectangular Square Round Rectangular Square Round
Color Operating voltage
5 VDC 12 VDC 24 VDC
Red A16-5DSR A16-12DSR A16-24DSR
Yellow A16-5DSY A16-12DSY A16-24DSY
Green A16-5DSG A16-12DSG A16-24DSG
White (See note.) A16-5DSW A16-12DSW A16-24DSW
Blue A16-5DA A16-12DA A16-24DA
Operating voltage 5 VAC/VDC 12 VAC/VDC 24 VAC/VDC
Model A16-5 A16-12 A16-24

Indicator M16 G-131
Pushbutton
Switches
Neon Lamp
Case
Socket
Specifications
■Approved Standards
Note: cUL: CSA, C22.2 No. 14
■Ratings
Super-bright LED
Note: The values in parentheses are for blue Pushbuttons.
Incandescent Lamp
Neon Lamp
■Characteristics
Note: Characteristics not provided above are the same as those for the A16.
Color of lamp Color of Display Operating voltage
100 VAC 200 VAC
Red White, red A16-1NRN A16-2NRN
Green Green A16-1NGN A16-2NGN
Appearance Classification Model number
IP40 Rectangular A16-CJM
Square A16-CAM
Round A16-CTM
IP65 oil-resistant Rectangular A165-CJM
Square A165-CAM
Round A165-CTM
Appearance Classification Model number
Solder terminals M16-0
PCB terminals M16-0P
Screw-Less Clamp M16-S
Solder terminals Voltage-reduction lighting 100 V M16-T1
Screw-Less Clamp 100 V M16-T1-S
200 V M16-T2-S
Agency Standards File No.
UL, cUL (See note.) UL508 E41515
Solder terminals
Rated
voltage Rated current Operating
voltage Built-in limiting
resistance
5 VDC 30 mA (15 mA) 5 VDC ±5% 33 Ω(68 Ω)
12 VDC 15 mA 12 VDC ±5% 270 Ω(560 Ω)
24 VDC 10 mA 24 VDC ±5% 1,600 Ω(2,000 Ω)
Rated voltage Rated current Operating voltage
6 VAC/VDC 60 mA 5 VAC/VDC
14 VAC/VDC 40 mA 12 VAC/VDC
28 VAC/VDC 24 mA 24 VAC/VDC
Rated voltage Rated current Operating voltage
110 VAC 1.5 mA 100 VAC ±10%
220 VAC 1.5 mA 200 VAC ±10%
Ambient operating temperature −10°C to 55°C (with no icing or
condensation)
Ambient operating humidity 35% to 85%
Ambient storage temperature −25°C to 65°C

G-132 Indicator M16
Screw-less Clamp
Dimensions
Note: 1. All units are in millimeters unless otherwise indicated.
2. Refer to page 134 for details of panel cutout dimensions.
Item Screw-less Clamp
Recommended wire size 0.5 mm2twisted wire or 0.8 mm-dia. solid wire
Usable wires and ten-
sile strength
Twisted wire 0.3 mm20.5 mm20.75 mm21.25 mm2
Solid wire 0.5 mm dia. 0.8 mm dia. 1.0 mm dia. ---
Tensile strength 10 N 20 N 30 N 40 N
Length of exposed wire 10 ±1 mm
M16 ×1
Rectangular
M16-J
Solder terminals
Square
M16-A
Solder terminals
Round
M16-T
Solder terminals
Mounting nut
Packing (t0.5)
Lock ring
Lamp terminals
Mounting nut
Packing (t0.5)
Lock ring
Lamp terminals
Mounting nut
Packing (t0.5)
Lock ring
Lamp terminals Terminal Hole Dimensions
Lamp terminals
14.6 dia.
18 dia.
18 dia. 15.1 dia. 18 dia.14.6 dia.
14.6 dia.
18 dia.
14.6 dia.
18 dia.

Indicator M16 G-133
Pushbutton
Switches
Direction-indication arrow
18 15.1
21
24
0.5
0.5
4.85 18.6
18.4 20.4
6.3
2.5
12.4
4
23.1
28.3
26.4
21.1
10.8
9.5
6
Rectangular
M16@-P
Rectangular
M16@-T1, T2
Lock ring
Mounting ring
Socket
Display
Case Marking face
Direction-indication arrow
Panel Cutouts
25 min.
16+0.2 dia.
0
Recommended panel thickness: 0.5 to 3.2 mm
Voltage-reduction lighting,
solder terminals
Packing (t0.5)
(for oil-resistant IP65 only)
23 min.
(Dimension A)
PCB terminals
Lock ring
Mounting ring
Packing (t0.5)
(for oil-resistant IP65 only)
Panel Cutouts
24 min.
16+0.2 dia.
0
24 min.
Recommended panel thickness: 0.5 to 3.2 mm
The rectangular model is given here as a representative example.
Lamp terminals are provided even for non-lighting applications.
Rectangular
M16@-S
Screw-Less Clamp
Socket dismounting lever Lock ring
Mounting ring
Packing (t0.5)
(for oil-resistant IP65 only)

G-134 Indicator M16
■Terminal Arrangement
■Panel Cutouts
Solder Terminals
Installation
Refer to the Installation section for the A16.
Solder Terminals Screw-Less Clamp Voltage-reduction Lighting
Side with TOP indicated
Bottom View
Side with TOP indicated
Bottom View
Bottom View Black
Red
Note: The L+ is not shown
on the Socket Unit.
Note: Voltage-reduction lighting mod-
els with Screw-Less Clamps
(A16L-@T1-2S, A16L-@T2-2S)
incorporate voltage-reduction
circuits.
Solder Terminals
Rectangular M16@-J
(Top View) (Top View)
24 min.
19 min.
16+0.2 dia.
0
19 min.
19 min.
25 min.
Screw-Less Clamp
(Top View)
Square M16@-A
Round M16@-T
16+0.2 dia.
0
16+0.2 dia.
0
Rectangular
M16@-S
32 min.
(Dimension A)
2. If the panel is to be finished with coating, etc., make sure that the panel meets the specified dimensions after coating.
Note: 1. Make sure the thickness of the mounting panel is 0.5 to 3.2 mm. If, however, a Switch Guard or Dust Cover is used, the
thickness of the mounting panel must be 0.5 to 2 mm.

Indicator M16 G-135
Pushbutton
Switches
Precautions
Refer to the Technical Information for Pushbutton Switches (Cat. No. A143) and the Precautions section for the A16.
■Correct Use
Mounting
When mounting the Case onto the Socket Unit, ensure that the orien-
tation is correct. Perform mounting with the • mark on the Case and
the TOP mark on the Socket Unit facing in the same direction.
Wiring
When using stranded wire, gather the ends of the strands together
before wiring.
When wiring, insert the wire until it comes into contact with some-
thing. After wiring is completed, pull on the wires to confirm that they
are connected securely.
After wiring, ensure that continuous pressure is not applied to the ter-
minals.
Refer to internal connections diagrams and confirm the terminal
numbers before performing wiring.
Screw-Less Clamps
Mounting Procedure
1. Strip a length of 10 mm off the end of the wire (allowable range:
10±1 mm).
2. Bunch wire strands together and straighten them.
3. Insert the wire into the insertion hole while pressing the release
button at the side of the hole. (Using a precision screwdriver is
recommended.)
4. Let go of the release button to lock the wire into place.
5. After locking, pull on the wire gently to confirm that it is securely
locked.
Removing Procedure
Remove wires by pulling them while pressing the release button.
Note: When reusing wires that have already been locked, cut off the
end of the wire and strip the wire again before using.
Case
TOP mark
•mark
Socket Unit

G-136 Indicator M16
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. A127-E1-02
Table of contents
Other Omron Measuring Instrument manuals

Omron
Omron H7E User manual

Omron
Omron Z500 Series User manual

Omron
Omron EQUO Series User manual

Omron
Omron K3GN User manual

Omron
Omron H7CX-R11-N User manual

Omron
Omron HEM-CS24 User manual

Omron
Omron HEM-RML30 User manual

Omron
Omron Z500 Series User manual

Omron
Omron ZN-DPX21-S Series User manual

Omron
Omron K6PM-TH User guide

Omron
Omron K7DD User manual

Omron
Omron ZX-GT - User manual

Omron
Omron K35-2 User manual

Omron
Omron K3HB-PPB Use and care manual

Omron
Omron K6CM series User manual

Omron
Omron Supergate 8615 User manual

Omron
Omron H7CC-A Series User manual

Omron
Omron H7CX - User manual

Omron
Omron G9SX Series User manual

Omron
Omron H7CX-N - User manual